OLT3610 8-Port GPON OLT with 4 × Gigabit Combo
User Guide
Introduction
Thank you for choosing OLT3610-08GP4S GPON. This guide is designed to
familiarize you with the layout of the GPON OLT and describes how to deploy it
in your network.
Accessories Optional(Not Included)
Hardware Overview
Front Panel
No | LED | Description |
---|---|---|
1 | P1 | Power indicator 1:When PWR1 supplies power, the indicator is on. |
2 | P2 | Power indicator 2: When PWR2 supplies power, the indicator is on. |
3 | SYS | System indicator: |
If the indicator is always on, the system is being started; If the indicator
flickers, the system works normally.
4| ALM| Alarm indicator:
If the indicator is off, the system works normally;
If the indicator is always on and the temperature of the device is over high,
please check the device.
5| G1-G8| ACT/link indicators of each Gigabit port:
If the indicator is always on, the link on the port is normal.
If the indicator flickers, there is data transmission through the port.
6| T1-T4| ACT/link indicators of each lOGE port:
If the indicator is always on, the link on the port is normal;
If the indicator flickers, there is data transmission through the port.
7| P1-P8| ACT/link indicators of each PON port
If the indicator is always on, the port is connected to ONU;
If the indicator flickers, there is data transmission through the port
No| LED| Description
---|---|---
8| CLI| CLI port: Manages GPON access device locally
9| MGMT| Management port: 100M external management port Realizes the upgrade
of the GPON access device
10| G1-G4| Gigabit TX ports: Forwards the 1000M Ethernet electric signals
11| G1-G8| Gigabit SFP ports: Forwards the 1000M Ethernet optical signals
12| T1 T4| 10GE SFP+ ports: Forwards the 10000M Ethernet optical signals
13| P1-P8| Gigabit OLT PON ports: Realizes the access of GPON ONU
14| /| PON debug serial port
Back Panel
No. | Description |
---|---|
1 | Grounding point. |
2 | P1/P2 power socket: AC100-240V, for Powerl/Power2. |
Installation Requirements
Safety Recommendations
- Keep clean and dust-free during or after the installation.
- Put the cover of the GPON at a safe place.
- Put tools at a right place where they will not easily fall down.
- Pay attention to the dress code when installing. Avoid damage to the GPON caused by improperly dressed.
- Put on the protective glasses if the installation environment may cause damage to eyes.
- Avoid improper operations that may cause personal injury or damage to the equipment.
Safety Principles for Live Working
If you operate devices under live working, please follow the safety
principles:
- Put off ornarnents.
- Pull out the AC power cord and close the direct-current power before operating on the chassis or working beside the power supply.
- Do not touch the power when power is on.
- Connect the device and the power socket correctly.
- Only professionals are allowed to operate and maintain the device.
Site Environment
- Make sure that the installation site is well-ventilated and the heat of electrical devices is well-discharged.
- Make sure the temperature of installation site is maintain. at 0-50°C.
- Follow the electrostatic discharge prevention procedure.
- Put the chassis at a place where cool air can blow off the heat inside the chassis.
Installation
Desk Mounting
Put the GPON on a smooth and safe desk directly.
Rack Mounting
-
Fix the mounting bracket to both sides of the GPON with screws.
-
Mount the GPON on a rack by fixing the mounting bracket to the rack.
Connecting the CLI Port
- Insert the corresponding end of the CLI cable into the CLI port of the GPON.
- Insert the other end of the CLI cable into the corresponding port of a computer host.
Connecting Ethernet Gigabit SFP Port
- Insert a GPON optical module into the SFP port(P1-P8) of the GPON.
- Connect the optical module to an optical splitter with a single-mode SC optical fiber cable.
- Then connect the splitter to an ONU with a fiber cable.
Connecting Ethernet Gigabit SFP Port
- Insert a SFP optical module into the SFP port (61-G8) of the GPON.
- Connect the optical module to a switch or other Ethernet terminal devices with a fiber cable.
Connecting Gigabit Ethemet TX Port Connect the the TX port(61-G4) of the
GPON to a switch or other Ethernet terminal devices with a direct-through or
cross Ethernet cable.
NOTE: When the ports (G1-.) are used as the TX ports, they cannot be used
as the optical
Connecting lOGE SFP+ Port
- Insert a SFP+ optical module into the SFP+ port(T1,14) of the GPON.
- Connect the optical module to a switch or other Ethernet terminal devices with a fiber cable.
Troubleshooting
- If the GPON access device is too hot, check whether the air outlet and air inlet are clean.
- If the GPON access device cannot be started and the Power indicator is off, check the power.
- If the port of the GPON access device cannot be linked, check whether the cable is correctly connected and whether the peer connection Is normal.
- If the CU port does not work after the system is started up, check whether the CLI port is set to a baud rate of 115200 bps, 8 data bits, no sum check bit, one stop bit and no traffic control.
Online Resources
- Download https://www.fs.com/productssupport.html
- Help Center https://www.fs.com/serviceffssupport.html
- Contact Us https://www.fs.com/contactus.html
Product Warranty
FS ensures our customers that any damage or faulty items due to our
workmanship, we will offer a free return within 30 days from the day you
receive your goods. This occludes any custom made items or tailored solutions.
Warranty: The GPON OLT enjoys 2 years limited warranty against defect in
materials or workmanship. For more details about warranty, Please check at,
https://www.f&com/policies/warrantyhtml
Return: If you want to return item(s), Information on how to return can
be found at: https://www.,com/policies/day_return_policyhtml
References
- Contact Us - FS.com
- Kontakt - FS.com Deutschland
- Rückgaberecht - FS.com Deutschland
- HPC, Rechenzentrum, Unternehmen, Telekom - FS.com Deutschland
- Technische Dokumente - FS.com Deutschland
- Hilfezentrum - FS.com Deutschland
- Comment Nous Contacter - FS.com France
- Politique de retour - FS.com France
- HPC, Datacenter, Enterprise, Télécom - FS.com France
- Documents techniques - FS.com France
- Centre d'aide - FS.com France
- Return Policy - FS.com
- Products Warranty - FS.com
- Technical Documents - FS.com
- Help Center - FS.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>