YHDC SCT036TS 36mm Aperture Split Core Current Transformer Installation Guide

June 9, 2024
YHDC

YHDC SCT036TS 36mm Aperture Split Core Current Transformer

Ф36mmAperture Split core current transformer

  • Front view

  • Opening view

  • Terminal view

Installation diagram

Primary threading method (Firing line)

Characteristic

  • Safety lock buckle, easy to install
  • Crimping terminal output
  • Can customize a variety of output
  • Suspended type

Product application

  • Portable instrument
  • Household metering
  • Monitor motor load

Product advantage

  • Small volume,Light weight
  • Low cost
  • High turns,High precision

Typical technical index:

  • Material of core——Silicon steel sheet
  • Working voltage——Phase voltage≤720V
  • Working temperature——-25℃~+60℃
  • Storage temperature——-30℃~+90℃
  • Frequency range——50Hz~60Hz
  • Dielectric strength——Input (bare conductor)/output AC 800V/1min 5mA 50Hz Output/Outer shell AC 3.5KV/1min 5mA 50Hz

Electrical parameters

Table
Table
Table
Table

:(The following parameters are typical values and actual values will be subject to product testing)

Wiring schematic diagram

Built-in sampling resistance oltage output type Secondary doesn’t allow short circuit

TVS: Transient voltage suppressor(5 A output without) Current output type Secondary doesn’t allow open circuit

Wiring schematic diagram

Read User Manual Online (PDF format)