PENTAIR Myers E-10 1.0 HP Effluent Pump Instruction Manual

June 9, 2024
Pentair

PENTAIR Myers E-10 1.0 HP Effluent Pump logo

PENTAIR Myers E-10 1.0 HP Effluent Pump

PENTAIR Myers E-10 1.0 HP Effluent Pump product

USAGE

The E10 is a submersible wastewater effluent pump designed specifically for individual residential and pressure applications. These pumps are for residential domestic use only and are not to be used for pumping commercial or industrial effluent such as from motels, schools, apartments, factories, etc.

CALIFORNIA PROPOSITION 65 WARNING:
This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

INSPECTING PUMP

Before making any piping or electrical connections, check the pump for shipping damage or cracks. Using a flat screwdriver placed in the slot on the shaft end, turn the shaft and impeller to be sure they are free. CAUTION: NEVER WORK ON THE UNIT WITHOUT DISCONNECTING THE ELECTRICAL POWER CORD.

POWER SUPPLY
The E10 effluent pump should be connected only to a 230 volt, single phase, 60 Hertz power source. The pump will draw approximately 8.2 amperes at minimum flow and 10.5 amperes at maximum flow rate. The pump must be connected to a grounded power socket. DO NOT cut off the ground pin from the power cord plug.

POWER CORD
A 20 foot power cord is attached to the effluent pump via a quick-disconnect positive sealing socket design. The power cord should be replaced if it has been damaged in any way or the cord jacket has become brittle with age.

FLOAT CONTROL

The float control has the same type of cord end connector as the power cord. The “OFF” and “ON” cycle times can be increased by setting a slightly longer tether length between the clamp and the float.

MOTOR
The E10 effluent pump contains a single phase, capacitor start, 3450 RPM motor. Overload protection is provided by an on-winding thermal protector which opens upon experiencing higher than normal temperatures. The protector will reset automatically upon cooling and the motor will restart. The motor chamber contains dielectric transformer oil to provide good heat transfer and lubrication of the ball bearings and seal; no other lubrication is required.
CAUTION – THE E10 EFFLUENT PUMP SHOULD NEVER BE WORKED ON WITHOUT FIRST DISCONNECTING THE POWER CORD.

CLEANING THE IMPELLER AND VOLUTE CASE

  1.  Unplug the pump.
  2. Remove the four (4) bolts that hold the volute case in place. CAUTION: Do not remove the two (2) bolts that hold the seal plate to the motor housing.
  3.  Remove volute case and clean. Check that the discharge passage is not blocked with debris. Also, clean around impeller if necessary. Do not remove the impeller as oil will leak past the shaft seal.
  4. By turning the impeller clockwise, check that the impeller and motor turn. There will be some drag due to shaft seal friction.
  5. Replace the volute and start the four (4) bolts. Tighten the bolts down evenly and firmly; do not overtighten.

TROUBLESHOOTING

SYMPTOMS
Pump does not run or hum. See A, B, C, D, E or F.
Pump runs but does not deliver water. See G, H, I, J, K or L.
Pump runs and pumps out sump but does not stop. See M.
Pump runs but delivers only small amount of water. See I, J, K, L or N.
Fuse blows or circuit breaker trips when pump starts. See K, L, N, O or P.
Motor runs for short time then stops. Then after short period starts again. Indicates tripping overload caused by symptom shown. See K, L, N or P.

SOLUTIONS

  • Line circuit breaker may be off; or fuse, if used, may be blown or loose.
  • Water level in sump may be too low. Run in more water.
  • Pump cord plug may not be making contact in receptacle.
  • If pump is using the series cord plug, the two plugs may not be plugged tight together.
  •  Float may be stuck. Be sure float operates freely in basin.
  •  If all symptoms check OK, motor winding may be open; take to service center for check.
  • Check valve may be installed backward. Arrow on valve points in direction of flow.
  • Discharge shut-off valve, if used, may be closed.
  • Pump may be air locked. Start and stop several times by plugging and unplugging cord. Check vent hole on pump case for plugging.
  • Pump head may be too high. Pump cannot deliver water over 108 ft. vertical. Horizontal distance does not affect pumping, except loss due to friction.
  •  Inlet holes in pump base may be clogged. Remove pump and clean out openings.
  • Impeller or volute openings may be plugged or partially plugged. Remove pump and clean per maintenance instructions.
  • Float is stuck in up position. Be sure float operates freely in basin.
  • Pump impeller may be partially clogged causing motor to run slow, resulting in motor overload.
  • Fuse size or circuit breaker is too small. Must be 15 amps.
  • Defective motor stator. Return to Myers service center.PENTAIR Myers E-10 1.0 HP Effluent Pump 01
Ref. No. Part No. Description
1 21929A002 BOLT, EYE, 3/8-16
2 24472D001 CAP (AFTER NOV. ’89)
3 05876A125 O-RING, 6-1/8 x 5-7/8 x 1/8″ (2 REQ’D)
4 18475A003 SCREW, 1/4-20 x 7/8″ LG., SST (8 REQ’D)
5 24466D000 HOUSING, MOTOR
6 24467B000 MOTOR, 230V, 1 PH., 2 POLE
6A 19331A005 WASHER, SPRING FINGER
7 22447A000 SEAL, ROTARY, 5/8″
8 24473C000 PLATE, SEAL
9 24463D001 CASE, VOLUTE
10 19099A014 SCREW, 1/4-20 x 1-1/2” LG., SST (4 REQ’D)
11 24465B000 IMPELLER
12 21628B019 CORD, ELECTRIC, 20 FT., 230V
13 24709110000 OIL, TRANSFORMER (2-1/2 QTS.)
14 09859A800 WIRE, JUMPER
15 09822A032 SCREW, NO. 10 x 3/8″ LG.
16 22071A001 CLAMP, CABLE
17 21813B107 CONTROL, FLOAT
18 05022A056 PLUG, PIPE, 1/4 NPT (AFTER NOV. ’89)
18A 18464A000 TAPE, TEFLON®
19 23395A000 EMBLEM, OIL LEVEL
20 24469A001 SCREEN
21 09822A020 SCREW, NO. 8 x 1/2″ LG. (4 REQ’D)

DISCHARGE ELBOW

Ref. No.| Part No.| Description
30| 24460B000| ELBOW, DISCHARGE
31| 05014A184| GASKET
32| 19099A024| SCREW, 1/4-20 x 1-1/4″ LG.
33| 05030A171| WASHER, FLAT
34| 05454A023| WASHER, LOCK
35| 19109A077| NUT, 1/4-20

STANDARD LIMITED WARRANTY

Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start- up through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility. This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts.

Warranty Exclusions: PENTAIR MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. PENTAIR MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation: IN NO EVENT SHALL PENTAIR MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY PENTAIR MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. PENTAIR MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. PENTAIR MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Myers shall vary or expand the provision hereof.
1101 MYERS PARKWAY ASHLAND, OHIO, USA 44805 419-289-1144
WWW.FEMYERS.COM
Warranty Rev. 12/13
490 PINEBUSH ROAD, UNIT #4
CAMBRIDGE, ONTARIO, CANADA N1T 0A5 800-363-PUMP

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals