MARTINIC 929192 Scanner Vibrato User Manual
- June 9, 2024
- MARTINIC
Table of Contents
MARTINIC 929192 Scanner Vibrato User Manual
Introduction
Thank you for purchasing or trying Martinic Scanner Vibrato.
Scanner Vibrato is a virtual effect plugin that aims to recreate the scanner vibrato effect from a well-known tonewheel organ.
A Brief History
The original scanner-vibrato was developed in the 1940s and was an analog, electromechanical device, consisting of an analog delay line and a mechanical rotor (“scanner”). The rotor was driven by the organ’s internal motor, and therefore its rate was fixed at about 6.9Hz. The original scanner-vibrato could produce both chorus and vibrato effects, and it offered three depth presets.
Our Scanner Vibrato
Martinic Scanner Vibrato is modeled closely on the original scanner-vibrato, offering the same features (and flaws) to perfectly preserve the character of the original effect. However, Scanner Vibrato is more flexible: you can adjust the rate, depth, and even stereo width. And best of all, you can apply Scanner Vibrato not only to organ sounds, but also to guitar, synthesizer, or whatever sound you like.
Free Trial
Before purchasing a license, you are allowed to try Scanner Vibrato free of
charge for up to 30 days for testing purposes and in non-published work.
Installation
System Requirements
Scanner Vibrato is available as VST 2.4, AU (Audio Units), or CLAP (CLever Audio Plugin) effect plug-in, which means it needs to run inside VST, AU, or CLAP hosting software, e.g. Ableton Live, Cubase, GarageBand, Logic Pro, REAPER, Studio One, etc.
Although Scanner Vibrato should be able to run at any sample rate the host provides, a rate of at least 44.1 kHz is recommended.
Scanner Vibrato is designed to run on Windows 7 or newer, or Mac OS X 10.9 (Mavericks) or newer.
Windows Installation
To install Scanner Vibrato on Windows, download the Windows 32/64-bit VST/CLAP installer, and save it on your computer (e.g. in your Downloads folder).
Navigate to this folder, locate the installer and double-click on it, and then
click on the Next button to start the installation process.
Carefully read the license, and then click on the I Agree button to continue.
Next select which versions of the plugin you want to install. Select Customize
GUI Scale to manually override the scaling factor of the plugin in a later
screen. Optionally you can select License Key if you have purchased a license.
Click on the Next button to continue.
Optionally change the install location, and again click on the Next button. Then select your VST2 32-bit and/or 64-bit plugin folder, and optionally select your license key file (if you have purchased a license), confirming each selection by clicking on the Next button.
If you have previously chosen to customize the GUI scale, you will be able to
select different options before selecting Next to begin installation.
Now wait for the installation to complete (this should take only a few seconds), click on the Close button, and you are ready.
Mac Installation
To install Scanner Vibrato on Mac OS X or macOS download the Mac 64 bit
VST/AU/CLAP installer disk image (DMG), and save it on your computer (e.g. in
your Downloads folder).
If you have purchased a license, then you should copy your license key file to the same folder in which you have saved the installer disk image (DMG), so it can be installed along with the plug-in(s).
Navigate to the folder in which you have saved the installer, locate the installer disk image (DMG) and double-click on it, and then double-click on the Scanner Vibrato Installer.pkg icon. Click on the Continue button to confirm that the installation package will run a program, and then click on Continue (in the bottom right corner of the installation window) to start the installation process.
Carefully read the license, click on the Continue button, and then click on
Agree. Next select which versions of the plug-in you want to install (it is
recommended that you install both the VST2 and AU versions, just to be sure),
optionally select License Key if you have purchased a license, and click on
the Continue button. Optionally change the install location, and then click on
the Install button.
Now wait for the installation to complete (this should take only a few seconds), click on the Close button, and you are ready.
Loading Scanner Vibrato
Launch your host, and create an audio track or load a project to which you want to add Scanner Vibrato. Please refer to the documentation of your hosting software on how to do this.
Note: Most hosts will list Scanner Vibrato as Martinic Scanner Vibrato, but some may list it as Scanner Vibrato or ScannerVibrato.
Scanner Vibrato is primarily meant to be used as an “insert” effect, which is also the way in which it was originally used. However, it can also be used as a “bus” effect.
Getting Around
Using the controls (plus fine-tuning and value entry)
You can adjust controls by clicking and dragging them up or down using the
mouse. To fine-tune a parameter to a more exact value, hover your cursor over
it, hold the Ctrl key (Mac and Windows), and scroll the mouse wheel. You can
also right-click on a knob to enter a value using the computer keyboard.
Double-clicking a knob or fader will reset it to its default value.
FX view and Settings view
The Scanner Vibrato can be used in either FX view or Settings view.
FX view allows you to control some of the Scanner Vibrato’s parameters, as you
would on an organ that has a scanner-vibrato built-in.
Settings view provides an abstracted set of controls for the plugin, giving you control over every parameter on the Scanner Vibrato. Here you can access all the controls, including master volume, Reverb Mix, Panning Mix, Delay Tape Age and Delay Mono/Stereo.
Scanner Vibrato is a stereo effect, so it is applied to both the left and right channels. When the switch is off the effect is bypassed. Note that this is likely not the same as bypassing Scanner Vibrato in your hosting software, because the input signal is still fed into the effect, meaning that you can turn it on again at any time, smoothly and without any pops or clicks.
How it Works
The original scanner-vibrato had only a few controls: an On/Off rocker switch
to bypass or insert the effect, and a rotary selector to choose an effect
type, and a depth preset for that type. Martinic Scanner Vibrato offers the
same basic controls, as well as several extra controls to tweak the effect to
your liking.
You can apply either a vibrato or chorus effect with variable intensity using the rotary selector, and adjust the characteristics of the sound using the Rate, Depth, Width and Mix knobs on the right hand side of the plugin.
Using the controls
You can adjust controls by dragging them up/down using the mouse, or you can use the mouse wheel while holding the Ctrl key down. You can also right-click on a knob to enter a value using the computer keyboard.
Shift and Double-click
Holding Shift and dragging a knob on either side of the unit will control the corresponding knob on the opposite channel at the same time.
Double-clicking a knob or fader will reset it to its default value.
On/Off
On the left, you will find the On/Off rocker switch. You can toggle it on/off by clicking on it using the left mouse button, or you can move the switch using the mouse wheel.
Scanner Vibrato is a stereo effect, so when the On/Off switch is on, the effect is applied to both the left and right channels. When the switch is off the effect is bypassed. Note that this is likely not the same as bypassing Scanner Vibrato in your hosting software, because the input signal is still fed into the effect, meaning that you can turn it on again at any time,smoothly and without any pops or clicks.
Vibrato/Chorus
Next to the On/Off switch, you will find the large Vibrato/Chorus rotary selector. You can change the selector by dragging it up/down using the mouse, or you can use the mouse wheel.
The Vibrato/Chorus selector lets you choose from chorus or vibrato modes, and at the same time it also lets you select from three depths, from light to heavy, making for a total of six presets:
- V-1 – Vibrato/light
- C-1 – Chorus/light
- V-2 – Vibrato/medium
- C-2 – Chorus/medium
- V-3 – Vibrato/heavy
- C-3 – Chorus/heavy
Model, Sync and Volume
The button labelled Model in the Settings view toggles the instrument between
the previous v1.0.0 model and the remodeled v1.1.0. The latter is the default
when loading the plugin. Different presets are set to different models.
The Sync toggle switch synchronizes the Scanner Vibrato to the tempo of your DAW and switches the Rate knobs from a number to predetermined time signatures.
The Volume control ranges from -36dB to +24dB. This is an overall output control, so if you have created a nice balance between the two channels, adjusting the Master knob will preserve this balance, and alter the volume of everything in unison.
Rate-1 and Rate-2
Using the Rate-1 and Rate-2 knobs you can adjust the vibrato/chorus rate, ranging from stationary (0 Hz) up to 15 Hz. When Scanner Vibrato is used in stereo, Rate 1 controls the speed of the effect on the left signal, and Rate-2 controls the speed of the effect on the right signal.
The original scanner-vibrato had a fixed rate of about 6.9Hz, which is the default rate for Scanner Vibrato when the plugin is loaded.
Link and Width
In between the Rate-1 and Rate-2 knobs you will find the Link toggle switch. You can toggle it on/off by clicking on it using the left mouse button, or you can move the switch using the mouse wheel.
When the Link toggle switch is off (down) you can set Rate-1 and Rate-2
independently, and you can use the Width knob (below the Link toggle switch)
to go from mono (0%) to full stereo (100%), or anywhere in between. At full
stereo, you can hear Rate 1 being applied to the left channel, and Rate-2
being applied to the right.
When Link is on (up) Rate-1 determines the rate for both channels, and Rate-2 is ignored. Now you can use the Width knob to change the phase relationship between the left and right channels, where 0% means in phase (mono), and higher values up to 100% increase
Depth
The Depth knob can be used to further adjust the vibrato depth. At 0% you will get only a tiny bit of vibrato/chorus, but raising the Depth creates more modulation until at 100% it will sound like the emulated electronic contacts need cleaning. This is especially noticeable when the Vibrato/Chorus selector is at a higher setting itself (eg C-3 or V-3).
Mix
When the Vibrato/Chorus selector is set to a chorus (C) preset, you can adjust the dry/wet mix using the Mix knob. At 0% you will get only the (semi) dry signal, at 100% you will get only the wet (vibrato) signal. The default dry/wet mix of 35% will give you the typical tonewheel chorus.
When the Vibrato/Chorus selector is set to a vibrato preset, the dry/wet mix has a fixed value of 100% wet, and the Mix knob is ignored.
Default Presets
In the VST version of the plugin, the top bar allows you to select between the
Default Presets that will be shown in your DAW. You can navigate between these
using the left and right arrow keys either side of the name.
Scanner Vibrato comes with 16 factory presets. These include Classic V-1, V 2, and V-3, and Classic C-1, C-2, and C-3, which are modeled on the original vibrato and chorus presets.
Full Features List
- Chorus/vibrato effect unit from well-known tonewheel organ
- Improved ACE® technique model
- Original C-1/C-2/C-3/V-1/V-2/V-3 depth/mix settings
- Adjustable rate, depth, and mix
- Optional stereo width with separate left/right rates
- 16 presets, from classic chorus/vibrato to rotary-like effects
- Tempo sync
- Output volume control