INSTALLATION INSTRUCTION

  • Weather station x 1
  • Outdoor sensor x 1
  • Power adapter for base unit x 1
  • Instruction manual x 1

Device overview (main unit)VENTUS W225 WiFi Connected 5 Day Weather
Forecast Station-fig-1
LCD display and function keys (main unit)VENTUS W225 WiFi Connected 5
Day Weather Forecast Station-fig-2

  1. WIFI signal identification
  2. DST mark
  3. Date
  4. time
  5. Week
  6. Alarm clock on/off sign
  7. Indoor equipment battery indicator
  8. Alarm week setting logo
  9. indoor temperature alarm mark
  10. Indoor comfort indicator
  11. The sign of MAX/MIN indoor temperature and humidity
  12. Indoor humidity
  13. Indoor temperature
  14. Today’s weather forecast-UV index
  15. Today’s weather forecast-weather conditions
  16. -17. Today’s weather forecast-MAX/MIN temperature 18-20. 5 days weather forecast
  17. 22. Outdoor temperature alarm mark
  18. Outdoor temperature and humidity MAX/MIN sign 24.-25.
  19. Outdoor humidity / temperature
  20. Outdoor sensor receiving sign
  21. Outdoor sensor battery indicator
  22. Outdoor sensor channel identification

Sensor

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-3

Function keys (outdoor sensor)

  1. Current channel
  2. Outdoor temperature
  3. Outdoor humidity
  4. Red pilot light
  5. Loop for hanging
  6. Sliding swith 1 2 3: Set sensor number (transmission channel)
  7. Battery compartment

Setup

Follow the instructions in the order described and first put the batteries in the wireless sensor. This is the only way for the weather station to function without any problems. Do not press any buttons while switching the device on.

Battery operation

  1. Remove the battery compartment cover.
  2. Insert 3 AAA / 1.5 V batteries facing in the direction indicated on the bottom of the battery compartment. Make sure that the poles of the batteries are correct (+/-).
  3. Put the battery compartment cover back in place and close it.
  4. Wait several minutes. The base unit needs this time to collect all the weather data and to receive radio signals from the time signal transmitter.

YOU SHOULD INSTALL THE APP, AS FOLLOWS:

  1. Download Tuya Smart APP

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-4

  1. Click 1 to install the app

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-5

  1. Fill in 1 and 2 to register account

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-6

  1. Click 1 to add a device

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-7

  1. To enter this interface, you need to long press the device SNOOZE.LIGHT button, click 1 to automatically discover the device or add a device when 2 appears.

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-8

  1. After the addition is complete, enter the five-day weather control interface.

VENTUS W225 WiFi Connected 5 Day Weather Forecast Station-
fig-9

Opration instructions!

Manual adjustment
  1. Power on or reset, and enter the
    • RF receiving state at the same time RF symbol, flashes exits the receiving state after 3 minutes, and Out displays the temperature and humidity of the corresponding CH.

General operation

A total of 6 buttons: Mode, Channel, Alert, +, -, Snooze/Light

  1. Single press Mode key to switch display: → time AL1AL2AL3 —
  2. When the Alarm is displayed, press and hold the ”Mode” key for >3 seconds to enter the corresponding Alarm setting.
  3. Single press ”Alert” to turn on or off the Alert alarm.
  4. Press and hold the ”Alert” key for >3 seconds to enter the Alert setting
  5. Single press ”+” key to view Max/MIN records,
  6. When the MAX/MIN value is displayed, press and hold the ”+” key for >3 seconds to clear the MAX/MIN record
  7. Single press the ”-” key to switch the temperature unit: °C/°F
  8. Press and hold the ”-” key for >3 seconds to switch the air pressure unit hpa/InHg
  9. Press and hold the ”Channel” key for >3 seconds to clear the RF record and re-register.
  10. Single press the ”Snooze/ Light” button to turn on the backlight for 10 seconds (battery powered)
  11. Press and hold the ”Snooze/ Light” button for >3 seconds to update the time & weather forecast

All settings must be made quickly, otherwise the setting screen will automatically revert back to the normal time dipsplay mode.

Time setting

  • In the normal mode, press and hold the ”MODE” button for 3 seconds to enter the time setting mode
  • The year will flash, you can press the button to set, and then press ”MODE” to confirm.
  • MD will flash, you can press ”UP” or ”DONW” key to set, and then press ”MODE” to confirm.
  • The month will flash, you can press the ”UP” or ”DONW” key to set, and then press ”MODE” to confirm.
  • The date will flash, you can press the ”UP” or ”DOWN” key to set, and then press ”MODE” to confirm.
  • 24/12 HR will flash, you can press ”UP” or ”DOWN” key to set, and then press ”MODE” to confirm.
  • The time zone will flash, you can press the ”UP” or ”DONW” key to set, and then press ”MODE” to confirm.
  • The hour will flash, you can press the ”UP” or ”DOWN” key to set, and then press ”MODE” to confirm.
  • The minutes will flash, which can be set by pressing the ”UP” or ”DOWN” key, and then press ”MODE” to confirm.
  • Press the ”UP” or ”DOWN” button, the seconds will flash and clear, then press ”MODE” to confirm.
  • If the button is not operated within 20 seconds, the setting mode will automatically exit and the set value will be saved.

Alarm & Settings

There are 3 groups of alarms by default. The default time 7:00 shows:

  1. Setting operation:

    • Press Mode key to switch display A1 A2 A3
    • Press ”+” or ”-” to on/off the corresponding Alarm
    • Long press the Alarm key for 2 seconds to enter the corresponding Alarm setting
    • Setting sequence: Hour → Minute → Mode → Exit
    • Mode sequence: All → weekdays → weekends
    • During the setting process, single press ”+” or ”-” to move forward or backward by 1 step. Long press for 3 seconds to quickly set 8 steps per second
    • After the setting is completed, the corresponding Alarm will be turned on automatically
    • 10 seconds without any operation, it will save the existing settings and return to the time display, automatically turn on the corresponding Alarm
  2. Alarm:
    When the Alarm is triggered,

    • The alarm sound is divided into 4 sections, 1~10S Bi once, 10~20S BiBi 2 beeps, 20~30S BiBiBiBi 4 beeps, long beeps after 30 seconds.
    • The alarm symbol flashes
    • Alarm time: 2 minutes
    • When the Alarm conflicts, the new Alarm will take precedence.
    • Press the ”Snooze” button, the alarm will be delayed for 5 minutes
    • Press any key to cancel Alarm.
    • In Snooze state, press any key to cancel Snooze.

Min / Max function:

In the normal time display mode, single press the ”UP” key to display the MIN and MAX values measured on the day.
Only the maximum values appear, then the minimum values and the current values again. Meanwhile, “MAX” or “MIN” is displayed above the values.

  • In the MAX/MIN value display mode, long press the ”UP” key to clear the MAX/MIN value
  • Automatically clear the MAX/MIN value at zero every day

Comfort level indicator (8)

  1. Dry: Indoor humidity less than 40%
  2. Comfort: when Indoor temperature is 20-28%, humidity between 40-70%
  3. Wet: Indoor humidity greater than 70%
  4. No display: When the temperature is not 20°C – 28°C and the humidity is 40-70%, there is no comfort indicator

Temperature alarm & setting

  1. Single press the Alert key, on/off Alert, is lit to indicate Alert on.
  2. Press and hold the Alert key for >3 seconds to enter the Alert setting:
    •  Setting sequence: select indoor alarm/outdoor alarm, upper limit temperature and lower limit temperature
    • When indoor or outdoor is selected, the corresponding will flash
    • During the setting process, single press ”+” or ”-” to move forward or backward by 1 step. Long press for 3 seconds to quickly set 8 steps per second
    • If there is no operation for 10 seconds, the existing settings will be saved and return to normal display.
    • There can be no situation where the lower limit is higher than the upper limit.
  3. When the temperature alarm is triggered,
    • The temperature and alarm signs will flash.
    • The buzzer will beep once every second, every 10 seconds, stop for 50 seconds, and last for 5 minutes.Press any key to stop the alarm sound, and the corresponding temperature and alarm mark will continue to flash.
    • If the temperature returns within the threshold, the alarm sound will stop and normal display will be restored.

Memory

  1. 1. Press the ”+” key to switch the display: current temperature MAX temperature MIN temperature current temperature
    2. When MAX or MIN is displayed, long press the ”+” key> 3 seconds to clear the memory data, the buzzer will beep once, and the temperature will display ”–.-” for 3 seconds, and then return to the current temperature.
    3. When displaying MAX or MIN, if there is no operation for 10 seconds, it will return to the current temperature display.

Unit conversion

  1. Press the ”-” key to switch the temperature unit: °C, °F

Time & weather forecast

  1. Press the ”Snooze/Light” button to update the weather & time
  2. The meaning of weather graphicsVENTUS W225 WiFi Connected 5 Day Weather Forecast Station-fig-14

When the sign is lit, it means entering DST time.

Technical specifications

Main unit

Batteries: 3 x AAA / 1.5 V (Not included)
Temperature measuring range: 0°C to +50°C
Resolution: 0.1 °C
Temperature accuracy: 0°C ~ 40°C: +/-1°C, over 40°C: +/-2°C
Humidity measuring range: 20 % to 95 % relative humidity
Humidity measuring accuracy: +/- 5 % with a measuring range of 30% to 80%, +/- 8% for other measuring range
Resolution: 1 %

Sensor

Batteries: 2 x AAA / 1.5 V (Not included)
Temperature measuring range: – 50°C to 70°C
Temperature accuracy: 0°C ~ 40°C: +/-1°C, -50°C ~ 0°C and 40°C ~ 70°C: +/-2°C Transmission frequency: 433 MHz
Range: max. 50 meters (in open area)

Power adapter

Power supply: 230-240V~, 50 Hz 50 mA
Output: 5.0V 150 mA