Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in
accordance with applicable codes and standards (ANSI/NFPA 70), including fire-
rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any
questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices, after being made, should be turned upward and pushed carefully up
into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit,
Switch power off at Service panel and lock service disconnecting means to
prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing
your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate
without any obstructions. Allow a minimum clearance of 7 feet from the floor to
the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury,
Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or
less” And Use Mounting Screws Provided With The Outlet Box.
CAUTION: For Compliance with Local Codes and Regulations, If Installing
The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The
Outlet Box. Mount the secondary support safety cable through the reserved
nail/screw hole on the outlet box to the building structure (or the ceiling
joist).
WARNING: To reduce the risk of personal injury, do not bend blade holders
during installation to motor, balancing or during cleaning. Do not insert
foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet
box.
WARNING: To reduce the risk of fire or electric shock, this fan should
only be used with fan speed control part no. JY1126R manufactured by Satellite
Electronic ( Zhongshan ) Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any other solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may
be affected by this unit’s operation. Follow the heating equipment
manufacturer’s guideline safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical
supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and
can overheat if serviced by untrained personnel. If any servicing is required,
the product should be returned to an authorized service facility for
examination or repair.
All set screws must be checked and tightened where necessary before
installation.
Note: Suitable for use in damp locations. Install the fan under covered or
enclosed patios or porches.
Tools Required for Assembly (not included): Electrical Tape, Phillips
Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Before you begin installing the fan, Switch power off at Service panel and
lock service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the service panel.
Use AC 120V/60HZ power supply only.
Before installing this fan make sure the outlet box is properly installed to
the house structure. To reduce the risk of fire, electric shock, or personal
injury, mount to outlet box or supporting system acceptable for fan support.
(Mounting must support at least 35 lbs.)
Use metal outlet box suitable for fan support and use only the screws provided
with the outlet box (must support 35 lbs). Before attaching fan to outlet box,
ensure the outlet box is securely fastened by at least two points to a
structural ceiling member ( a loose box will cause the fan to wobble). Remove
the two outlet box screws provided with the box, aligning the holes of the
mounting bracket with the holes of the outlet box. Reinstall the 2 outlet box
screws securely.
Partially loosen downrod set screws from yoke at top of motor assembly. Remove
preassembled cross pin and keeper pin from downrod. Keep parts.
Place downrod over canopy and canopy bottom cap. Thread lead wires and safety
cable from motor assembly through downrod.
Slip downrod into motor housing yoke, aligning holes and install cross pin and
keeper pin.
Insert cross pin through yoke and downrod until point appears on the other
side, and insert keeper pin on cross pin.
Pull the downrod up tight against the cross pin, and then evenly tighten the
downrod set screws on motor housing yoke.
Warning: Cross pin and keeper pin must be installed securely, failure to
install them will result in serious injury.
Install ball end of downrod into mounting bracket opening. Align (engage) slot
on ball with tab on mounting bracket.
Warning: Failure to align slot on ball with tab may result in serious injury.
Important: If using the angle mount, make sure open end of mounting bracket is
installed facing the higher point of the ceiling and make sure the ceiling
angle is not steeper than 20º. Longer downrod may be necessary allowing the
fan blades to rotate without obstructions.
Safety cable must be installed into the house structure using 3” lag screws,
washers, and lock washers provided, required for outdoor applications and in
Canada (All fans installed in Canada), and for USA fan and light kit
combinations over 35lbs.
Make sure that when the safety cable is fully extended the lead wires are
longer than the cable and no stress is placed on the lead wires.
Note: If Installing The Secondary Support Safety Cable in the U.S., Do
Not Remove Knockouts In The Outlet Box.
Make wiring connections using wire connectors provided as indicated above.
Brown wire from fan to Brown wire from receiver marked Motor U.
Gray wire from fan to Gray wire from receiver marked Motor V.
Orange wire from fan to Orange wire from receiver marked Motor W.
White wire from fan marked “For light” to White wire from receiver marked “For
light”.
Blue wire from fan marked “For light” to Blue wire from receiver marked “For
light”.
White (Neutral) wire from house to White wire from remote marked AC IN N.
Black (Live) wire from house to Black wire from remote marked AC IN L.
Connect all green grounded wires to Grounded wire from House.
Make sure that no filaments are outside of the wire connectors.
Insert the remote receiver into mounting bracket.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices after being made should be turned upward and pushed carefully up into
the outlet box.
Caution: The installation has to be complete before operate the fan.
Receiver has to be used on the fan and cannot be bypassed.
Partially loosen one and remove one preassembled screw from mounting bracket.
Save screw.
Lift canopy up, aligning its keyhole slot with the preassembled screw on
mounting bracket and twist clockwise to lock in place. Reinstall the screw
removed and tighten all screws securely.
Attach canopy bottom cap onto canopy by aligning its holes with the screws on
mounting bracket and fix it with the magnet which is embedded in the cap.
Install blade onto the blade bracket with a blade supporting plate as shown above by 3 blade screws provided. Tighten screws securely. Repeat this process for remaining blades. Attach a blanking plate by locating dimples in light pan with grooves on the blanking plate and twist clockwise until tight.
Remote Controller Operation
Remove the battery cover from the remote control transmitter and install
batteries.
Replace the cover. This remote uses 2 1.5V/AAA batteries.
Note: If not using for long periods of time, remove battery to prevent damage
to remote transmitter, and store the remote transmitter away from excess heat
or humidity
Dimming, Non Dimming Setting (Only available for fans with light)
In the dimming mold, it is a light dimming selection and it is to be used with
dimmable luminaries. The remote controller is set with dimming function at
factory.
In ON/OFF (non-dimming mold), it is for light ON/OFF only (non-dimming
function).
Universal Mode and Learning Mode
There are “Universal Mode” and “Learning Mode” (marks “0” and “1”) with the
remote controller.
If choosing “Universal Mode”, simply place dip (code) switch at LOWER position
(mark “0”). Your fan with the remote controller is ready to use.
Note: If using universal mode, your fan can be controlled with other
remote transmitters with the same setting.
To control the fan with specific remote transmitter, choose “Learning Mode” by
placing the dip (code) switch at UPPER (mark “1”) position and then make learn
function setting as below. Learn Function Setting
Important: Turn the power on for ONLY the specific fan you wish to pair with
the remote controller. Make sure to turn the power off for all other fans with
which you use the same remote controller.
Restore power to your fan, press and hold the “SET” button to pair the
Transmitter and receiver. You must press the ‘SET” button within 60 seconds of
restoring power to the fan.
Note: Fan will operate at minimum speed and light will blinks (If the fan
installed with a light) after the setting.
Note: If the power is on already, you must turn the power off then turn
the power back for remote control setting.
Note: If reset the dip switch to “0” position (universal mold). It has to
be paired again, run the learn function setting.
The buttons on the remote control transmitter control the fan speed and light
as follows.
Fan speed
- = minimum speed
- = low speed
- = medium low speed
- = medium speed
- = medium high speed
- = high speed
This button turns the fan off.
Forward/Reverse button- This button is to control direction of fan rotation.
Press once to change direction of the fan rotation. Fan must be running to
reverse.
Light button- Press this button to turn light on or off.
Light button- Press this button to desired brightness, dim to bright.
Light button- Press this button to desired brightness, bright to dim.
Note: light buttons is for the fan installed with a light.
Breeze
Press the Breeze button, the fan will operate at high speed (6 th ) for 30
seconds, then automatically change to 5 th , 4 th , 3 rd , 2 nd , 1 st at
intervals of 30 seconds, and then change it from Low speed (1 st ) to 2 nd , 3
rd , 4 th , 5 th , 6 th repeat the cycle until the breeze mold is canceled.
Breeze mold can be erase by pressing the buttons of power or speed control.
Note: This remote controller has auto resume function, the fan and light
will maintain the last setting if turned off with exception of the Breeze
mold.
Install Transmitter wall mount cradle with 2 screws provided.
Useful tips:
Take remote transmitter up by pushing it at lower area of the transmitter.
The remote transmitter can be held on magnetic metal materials by a magnet
built in the transmitter.
The receiver provides the following protective
functions
Lock protection- The DC motor has a build-in safety feature against blade
obstruction during operation. If something obstructs the fan blades, the motor
will stop operation after about 20 seconds of interruption. Please remove
obstacles and reset it by turning the power off, and turn it back.
Over 40W protection- When the receiver detects motor power consumption which
is greater than 40W, the fan RPM will be lowered to protect it from
overloading.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS. (1)THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE
AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
User Tips
- If your fan is operating automatically after installation, it is still using the factory setting. Follow the settings for Learn Mode above to reset.
- If the fan or light isn’t working, reset power (turn the power off then turn the power back on) and follow the Universal Mode or Learn Mode remote control settings.
- If two or more fans in the same remote signal range are on the same power supply, they cannot be operated separately by remote control. Use a separate power supply for each fan, such as an individual wall switch, and restrict the power supply to only the fan which you are pairing with its transmitter in order to use the remote controller.
- When the fan is turned on to oscillate in either forward or reverse direction, it may shudder briefly until fully engaged. This is a normal operation for this fan; the shuddering will quickly cease as movement is engaged.
Troubleshooting
If you have difficulty operating your new ceiling fan, it may be the result of
incorrect assembly, installation, or wiring. In some cases, these installation
errors may be mistaken for defects. If you experience any faults, please check
this Troubleshooting Chart. If a problem cannot be remedied, or you are
experiencing difficulty in installation, please call our Customer Service
Center at the number printed on your parts list insert sheet.
Warning: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Trouble | Suggested Remedy |
---|---|
1. If fan does not start: | 1.Check main and branch circuit fuses or circuit |
breakers.
2.Check line wire connections to fan and switch wire connections in switch
housing.
CAUTION: Make sure main power is turned off.
3.If this fan uses manual forward/reverse switch, make sure the switch is
pushed firmly either way. Fan will not operate when switch is in the middle.
4.If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
2. If fan sounds noisy:| 1.Check to make sure all screws in motor housing are
snug (not over tightened).
2.Check to make sure the screws which attach the fan blade holder to the motor
are tight.
3.Check to make sure wire nut connectors in switch housing are not rattling
against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch
housing.
4.Check to be sure light bulb is tight in socket and not touching the glass
shade.
5.Some fan motors are sensitive to signals from Solid State variable speed
controls.
6.Allow “break-in” period of 24 hours. Most noises associated with a new fan
will
disappear after this period.
3. If fan wobbles:
| 1.If this is a downrod mount fan, make sure the ridge on mounting bracket
engages the notch in the downrod ball.
2.Make sure that canopy, mounting bracket or mounting plate are tightened
securely to ceiling junction box and junction box is mounted firmly to ceiling
joist.
3.Check that all blades are screwed firmly into blade holders.
4.Check that all blade holders are tightened securely to motor.
5.Most fan wobble problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance from blade tip to ceiling. Keeping measure
within 1/8″, rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. If all blade levels are not equal, you can
adjust blade levels by the following procedure. To adjust a blade tip down,
insert a washer (not supplied) between the blade and blade holder at the screw
closest to the motor. To adjust a blade tip up, insert washer (not supplied)
between the blade and blade holder at the two screws farthest from the motor.
Reverse the position of the washer if blades mount from top of blade.
6.If blade wobble is still noticeable, interchanging two adjacent blades can
redistribute the weight and possibly result in smoother operation.
If the above steps do not eliminate the wobble problem, you will need to
dynamically balance your fan with balancing kit provided.
4. If light does not work:| 1.Check blue wire from fan to make sure it is
connected to hot wire from house.
2.Check for loose or disconnected wires in fan switch housing.
3.Check for loose or disconnected wires in light kit.
4.Check for faulty lightbulb and make sure bulb is tight in socket.
5.Remove light kit and check the plug connections if they are present.
6.If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch
housing and/or canopy.
Attach sales receipt to this card and retain as your proof of purchase
DATE OF PURCHASE:…………………………..
RETAILER NAME:………………………………….
MODEL NUMBER:………………………………..
RETAILER ADDRESS:………………………….
To register your fixture, please visit our website
www.montecarlofans.com
4.69 kg
10.32 lbs
Total fan weight
Customer Service
800-969-3347
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.montecarlofans.com
Documents / Resources
|
MONTE CARLO 3RZR52MBK Rozzen 52 in. Indoor/Outdoor Midnight Black Ceiling
Fan
[pdf] Instruction Manual
3RZR52MBK Rozzen 52 in. Indoor Outdoor Midnight Black Ceiling Fan, 3RZR52MBK,
Rozzen 52 in. Indoor Outdoor Midnight Black Ceiling Fan, Midnight Black
Ceiling Fan, Ceiling Fan
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>