GE current Allusion Series Lumination Linear Recessed Slot Owner’s Manual

June 9, 2024
GE current

GE current Allusion Series Lumination Linear Recessed Slot

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
product

Allusion Recessed is an architectural linear recessed platform offering long life, high efficiency, and enhanced color rendering provided by the included TriGain® technology. A variety of lens, intersection, housing color and accessory options are an ideal package for any specifier or architect’s tool box.

SPECIFICATIONS

CONSTRUCTION

Housing: Aluminum extruded housing. Diecast endcaps.
Lens: Impact resistent flush, glow, and wall wash lenses. Powdercoated

metal louvers.
Paint:| Powder painted, standard Black/White/Silver. Custom colors available
Weight:| 8-22 Lbs
Optical Assembly| Precision formed high efficiency reflector and optical diffuser

OPTICAL SYSTEM

Delivered Down Lumens:| 400-1100 lm/LFT

100 lumen Increments per linear

foot (LFT)

---|---
Down Distribution

Pattern:

| Medium, Louver (no lens), Glow,

Wall Wash

System Efficacy (LPW):| >90 LPW
CCT:| 3000K, 3500K, 4000K, 5000K
CRI (Min):| TriGain® 90, 90
Color Consistency| 4 Step MacAdam Ellipse

LUMEN AMBIENT TEMPERATURE

Product ID/Operating Temperature LALS -10° TO 30° C

ELECTRICAL

Input Voltage: 120-277V, 347V
Input Frequency: 50/60Hz

Standard Dimming

Control:

| 0-10V, Daintree Wireless Controls,

Lutron Ecosystem

Power Factor *(PF):| > 90%
Total Harmonic Distortion**

*(THD):**

| < 20%
EMBB| Integral EMBB (optional)
Maximum Run Length| 100 ft per 1 powerdrop

CONTROLS

  • Dimming : Standard – 0-10V, 1%
  • Daintree® Wireless
  • Lutron Ecosystem, Hi lume 1%

MOUNTING

  • T-Grid or Drywall
  • For Drywall applications, corner bead to finish drywall is not provided by manufacturer – must be provided by the installer. Refer to Installation Guide
  • Adjustable brackets allow for user-determined fixture reveal
  • Drywall configurations are secured to the structure and the adjacent ceiling. A LED cover is provided for protection of the interior components

ADDITIONAL NOTES

  • No visible LEDs for for MM, GL, and WW down light lens options
  • Use UL/cUL approved conduit fittings for 1/2” conduit trade size
  • Suitable for dry and damp locations
  • IC-Rated

Catalog Logic

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-1

Ordering Notes:

  1. 2ft length must have a minimum 800lm/ft. 2ft is available in Stand Alone/Starter (TS/DS mounting options).
  2. Louvers (LW option) are field installed and have no lens. Refer to Kits Section.
  3. Daintree controls (TQ or TS option) are only available with 120-277V (0 voltage option).
  4. Corner fixture (L9 option) is only available in 4ft length (length option 4). Refer to Dimensional information. Verify T-Grid dimensional information for proper layout.
  5. Contact manufacturer for quote on custom colors. Additional lead times and minimum order quantities are applicable.
  6. Integral Emergency Battery (EL option) only available with 120-277V (0 voltage option) and 0-10V controls (VQ option). EL is not available for 2ft lengths or Corner fixtures (L9 option).
  7. Chicago Plenum (CP option) meets CCEA requirements.
  8. Corner fixture (L9 option) with Wall Wash (WW) or Louver (LW) not available.

Dimensional Drawings

LALR2 / LALR4

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-2

T-GRID MOUNTING DETAILS

  • LALR2 – T-Grid mounted 3” on center
  • LALR4 – T-Grid mounted 4” on center

MOUNTING

  • Stand Alone/Starter dimensions are 3/8” shorter than specified length to allow for proper grid installation and include a pair of endcaps
  • Each row of connected fixtures requires one Stand Alone/Starter Fixture and the necessary quantity of Continuous fixtures to make the necessary length

LALR CORNER INTERSECTION

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-4

MOUNTING

  • Fixture is provided with (2) Knockout plates, (4) T-Grid Brackets, (4) Drywall brackets, and Male/Male and Female/ Female jumper harnesses
  • LALR Corner fixtures are Continuous and are intended to be installed with additional luminaires. a started fixture is recommended to provide end caps and power connections
  • Note : If no Starter fixtures are needed, a Leader Cable Kit #93120219 will need to be ordered separately. (see “Kits” section in IND546 LAL Series – Replacement Guide for additional information

Dimensions

Louvers (LW option)

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-5

  • Louver Length = 11 inches
  • ONE used in every LALR Starter Fixture
  • Louver Length = 12 inches
  • Multiples used in LALR Continuous Fixtures, depending on fixture length
  • Provided in separate packs with fixtures, to be installed on site (see Install Guide for proper orientation).
  • Louvers are matte white painted finish.
  • Louvered fixtures do not have a lens.

Wall Wash (WW option)
Length of Wall Wash Lens is equal to fixture lengths available

Note : All Starter Fixtures (TS/DS) are provided with flush lens end caps.

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-6

Glow endcaps are larger than flush lens end caps

Wall Wash (WW option)

Length of Wall Wash Lens is equal to fixture lengths available

Note : All Starter Fixtures (TS/DS) are provided with flush lens end caps.

Performance

**LALR2 Down Light***

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-10

**LALR4 Down Light***

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-11

NOTE :

  • Corner (L9) option, use LALR24 (24) or LALR44 (44) only from the Product Column in table above.
  • Glow (GL) Option is 5% less lumens than values shown above.
  • Wall Wash (WW) Option is 7% more lumens than values shown above

DOWN ONLY – MEDIUM FLUSH LENS
LALR-4-4-A-0-NA-00-MM-07-XXX-XX-WHTE-XX

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-12

Photometrics

DOWN ONLY – GLOW LENS
LALX-4-4-A-0-NA-00-GL-07-XXX-XX-WHTE-XX

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-13

DOWN ONLY – WHITE LOUVERS (NO LENS)
LALR-4-4-A-0-NA-00-LW-07-XXX-XX-WHTE-XX

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-14

DOWN ONLY – WALL WASH
LALR-4-4-A-0-NA-00-WW-07-XXX-XX-WHTE-XX

GE-current-Allusion-Series-Lumination-Linear-Recessed-Slot-
fig-15

Controls & Sensors

DAINTREE CONTROLS

  • Daintree® Wireless Controls:
  • There is no one size fits all for wireless controls. Some networks want simple solutions that reduce energy consumption and meet code compliance while others are more ambitious, looking to capitalize on the LED and controls savings to fund a scalable, enterprise-grade, internet of things solution. The advantage of the Daintree Wireless platform is it’s ability to integrate into indoor, outdoor and high bay environments. The Daintree Wireless Controls provide the infrastructure to future proof your buildings, easily upgrade to Networked solutions and provide the ability to integrate into IoT solutions that are right for your business.
    • Daintree One: Standalone Wireless Controls
    • Daintree EZ Connect: Room-Based Wireless Lighting Controls
    • Daintree Networked: Networked Lighting Controls for Smart Building & IoT Enablement
  • Daintree Wireless Controls are already integrated in your favorite Current LED fixtures. Integrating the controls into the fixture cuts labor costs considerably since the sensors are already embedded in the lighting fixtures. There’s no need to get above the ceiling plenum and install additional devices. Visit our website https://products.gecurrent.com for a complete list of LED Fixtures that have Daintree integrated controls.

LUTRON CONTROLS
Lutron Ecosystem
: EcoSystem technology is a control method for LEDs that provides addressing of individual fixtures and status feedback from the LED drivers. This makes it easy to digitally assign occupancy sensors, daylight sensors, time clocks, manual controls and other controls to one or many fixtures without complicated wiring. This opens up an entire suite of energy- saving, systemmonitoring and system-control schemes where the design, setup and rezoning are all done within software, making the electrical and control design simple

For Product or Technical Questions:

www.gecurrent.com
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. IND500 (Rev 02/04/22)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

GE current User Manuals

Related Manuals