Introduction

About this product
The Wiser Motion Sensor (hereinafter referred to as sensor), reports the detection of movement and measures the luminance of the environment, then passes this data to the Wiser Gateway.
The threshold of luminance settings and/or detection of movement can be programmed to determine what action is to be taken.

Package Contents

  • A. Motion sensor
  • B. Base plate
  • C. Adhesive pad
  • D. Screws: 2 × ST4.2 × 25 mm with wall plugs
  • E. Installation instructions
    Package Content

Choose suitable location to install

Locate To Install

NOTICE
RISK OF DAMAGE TO DEVICE

  • Always operate the product in compliance with the specified technical data.
  • Do not install the sensor in a place where there is strong sunlight or wind (for example, close to ventilation).
  • When the ambient temperature is >32 o C, the sensor’s ability to measure sensitivity, detection range and detection angle are degraded.
    Failure to follow these instructions can result in equipment damage.

The sensor can be mounted on a wall or ceiling to provide desired coverage:

  • Ceiling mount provides a 360° detection angle with a maximum range of 4 m diameter.
  • Wall mount provides a detection angle of 90° to 110° horizontal and vertical with a maximum range of 5 m radius.

Walking direction
The sensor is more sensitive to movement across different patterns.
On the Conversely, the sensor is less sensitive when movement is directly towards the sensor, since the range is reduced.

  • F. More sensitive to movement across the pattern
  • G. Less sensitive to movement directly towards sensor

Installing the sensor

Installing The Sensor

  1. Remove the battery isolation strip
    • A.  LED flashes green

Mount the base plate

  • a. Mounting using adhesive pads
    For wood or plastic surfaces or metal surfaces, use the adhesive pads.
    For metal surfaces, use the adhesive pads only.

  • b. Mounting using screws

    • For wood or plastic surfaces, use the screws.
    • If using screws, pre-drill a 1 mm hole.
  • c. Mounting on ceiling

  • (2) Mount the sensor on the base plate.

Read full device guide online

Device Guide

Scan the QR code and choose your language
for complete information about the device, including operation, configuration and using the product with a Wiser system.
_ Scan Me
QR. Code
_

Technical data

Battery 3 VDC, LR03 AAA × 2
Battery life Up to 5 years (may vary based on the usage, frequency

of firmware update and environment)

Nominal power| ≤90 mW
IP rating| IP20
Operating frequency| 2405 – 2480 MHz
Max. radio frequency power transmitted| ≤7 dBm
Operating temperature| -10 °C to 50 °C
Relative humidity| 10 % to 95 %
Lux measurement range| 0 lx to 2000 lx
Dimensions| Ø 75.0 × 26.6 mm
Communication protocol| Zigbee 3.0 certified
Ceiling mounted at 2.5 m
Detection angle| 360°
Detection range| Ø 4 m
Wall mounted at 1.2 m
Detection angle| 90° to 110° horizontal and vertical
Detection range| 5 m in radius

Trademarks

  • Wiser™ is a trademark and the property of Schneider Electric SE, its subsidiaries and affiliated companies.
  • Zigbee® is a registered trademark of the Connectivity Standard Alliance.
    Other brands and registered trademarks are properties of their relevant owners. Next trademark statement.

EU Declaration of Conformity

Hereby, Schneider Electric Industries, declares that this product is in compliance with the essential requirements and other relevant provisions of RADIO EQUIPMENT DIRECTIVE 2014/53/EU.
Declaration of conformity can be downloaded on: se.com/docs.

Schneider Electric Industries SAS
If you have technical questions, please contact the Customer Care Centre in your country. se.com/contact

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals