resideo R200C2-A R200 Monitor Installation Guide
- June 9, 2024
- resideo
Table of Contents
- R200C2-A R200 Monitor
- Introduction
- Explanation
- Where to install the device?
- Where not to install the device
- Mounting
- Status indicator – Green / Yellow / Red
- Explanation operation buttons
- Recommended actions when the CO2 Monitor warning has been activated
- Carbon dioxide levels and guidelines
- Maintenance
- Warnings
- Specifications
- Service and Contact
- Symbols
- Disclaimer
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
R200 Monitor
Installation and Setup Guide
R200C2-A R200 Monitor
Introduction
Thank you for the purchase of this carbon dioxide monitor. Carbon dioxide is also known as CO2. This product is designed for measuring CO2 concentrations as well as air temperature and humidity. To be used at home, office, school, canteen, etc. The CO2 monitor adapts itself to its environment (auto calibration). No settings need to be made. This CO2 monitor alerts users through voice messages and audible alarms. Always avoid exposure to high concentrations of CO2. This product, when used properly, is designed to alert you to elevated levels to CO2 so that you may take action to remove yourself from such environment.
- Accurate measurement of:
- carbon dioxide, ± 50ppm ± 5%
- temperature, ± 0.5°C or 0.9°F
- moisture, ± 5% RH
- LED status indication
- Voice alarm notification
- Automatic adjustment of the display brightness
- Rechargeable internal backup battery (approx. 12 hours)
Explanation
Number | Function | Number | Function |
---|---|---|---|
1 | Voice / siren output | 7 | SET/AUTO operation button |
2 | Green / Yellow / Red status indicator | 8 | TEST / HUSH operation button |
3 | Temperature indicator | 9 | Adapter connection |
4 | Humidity indicator | 10 | ON / OFF Switch back-up battery |
5 | CO2 indicator | 11 | Remove from mounting plate |
6 | Display | 12 | Attach to mounting plate |
Where to install the device?
The CO2 sensor needs a process that adapts to the current environment. In
order to achieve a more accurate detection effect, after changing the CO2
monitor’s location it should continue to work for more than 24 hours to
complete the automatic calibration. After the completion, the calibration will
not be performed at the next startup.
Ideally, a device should be installed in every room containing a fuel-burning
appliance and in a room where the occupant(s) spend most of their time, like
the living room, bedroom and study or hobby room.
The CO2 monitor can be wall mounted (eye level) – use cable input A (see page
2), or placed on a cabinet or table/desk – use cable input B (see page 2).
Where not to install the device
In an enclosed space (for example in a cupboard or behind a curtain).
Where it can be obstructed (for example by furniture).
Directly above a sink.
Next to a door or window.
Next to an extractor fan.
Next to an air vent or other similar ventilation openings.
In an area where the temperature may drop below -5°C or exceed 50°C.
Where dirt and dust may block the sensor.
In a damp or humid location.
In the immediate vicinity of a cooking appliance.
Mounting
The CO2 Monitor comes with screws and wall plugs for mounting on the wall. Remove the CO2 Monitor from the mounting plate, turn (11) counterclockwise approximate 15°. Use the mounting plate to mark the drill holes. After drilling, place the dowels in the holes and then screw down the mounting plate with the screws. Switch on the back-up battery (10), fully charged is approximate 12 hours usage without adapter connection. Connect the adapter to the CO2 monitor (9) and a power outlet. Place the CO2 Monitor on the mounting plate and turn (12) approximate 15° clockwise.
Status indicator – Green / Yellow / Red
When CO2 concentration is ≤1000PPM, the status indicator turns green.
When CO2 concentration is 1000PPM ~ 1500 PPM, the status indicator turns
yellow.
When CO2 concentration is ≥1500 PPM, the status indicator turns red and a
75db@1m alarm is emitted.
Take actions recommended in Section 8 to prevent risks to your health and
safety.
Explanation operation buttons
| Short press to switch between temperature, humidity and CO2 display.
---|---
| Short press to get temperature display and then long press to set degrees
Celcius or degrees Fahrenheit.
| Short press to get CO2 display and then long press to set alarm sound
ON/OFF.
| Long press to test the alarm.
Short press to delay/hush the alarm for 10 minutes.
| Within 150 seconds from turning the product on, press and hold both keys
simultaneously for 3 seconds. You will hear a voice message in the currently
selected language. Press again for 3 seconds and the selection moves to the
next available language.
Recommended actions when the CO2 Monitor warning has been activated
Keep calm.
Open all doors and windows and turn off all combustion appliances.
If the CO2 Monitor continues to sound the alarm, evacuate your home.
Leave all doors and windows open and do not enter until the alarm has stopped.
Seek medical attention for anyone who may be suffering from the effects of
carbon dioxide.
Carbon dioxide levels and guidelines
400 PPM | Normal outdoor air level |
---|---|
400 ~ 1000 PPM | Typical level indoors with good ventilation. |
NOTE: If CO2 levels are low when building is sealed and occupied, check for overventilation (too much fresh air = energy wasted).
1000 PPM| ASHRAE and OSHA recommended maximum level in a closed room.
Considered maximum comfort level in many countries.
1200 PPM| Poor air quality – requires ventilation.
2000 PPM| According to many studies this level of CO2 produces a significant increase in drowsiness, tiredness, headache lower levels of concentration and increased likelihood of spreading respiratory viruses like colds, etc.
5000 PPM| OSHA and NIOSH first threshold for safety. Maximum allowed concentration withinan 8 hour working period.
Maintenance
We recommend to manually test CO2 Monitor once a month by pressing and holding
the test button.
Dust is a major cause of false alarms. Therefore, clean the CO2 Monitor once a
month. Use a vacuum cleaner to gently remove any accumulated dust along the
sides of the CO2 Monitor. Never use a wet cloth or detergent to clean your CO2
Monitor. Clean the device with a soft, damp and lint-free cloth. Make sure
that no moisture enters the housing. Do not use any sprays, solvents, alcohol-
based cleaning agents or abrasive cleaners, but only clean water to moisten
the cloth.
Warnings
This manual contains important safety information about the CO2 Monitor.
Read the manual carefully and keep it in a safe place for future reference.
Do not open the device in case it is damaged.
Do not remove any safety signs, stickers or labels from the device.
Keep all safety signs, stickers and labels legible condition.
This product cannot be used in factories, warehouses and other industrial
environments that may be in high CO2 concentration for a long time.
If the product is to be placed in a narrow space, the space should be well
ventilated, especially the two diffusion windows should be in a well-
ventilated position.
The product should be away from heat source, and avoid direct sunlight or
other thermal radiation.
This product should not be used in the environment with high dust density for
a long time.
Specifications
Working voltage | : DC5V (Power adapter 5V/1A) |
---|---|
Sensor type | : None-dispersive infrared (NDIR) sensor |
CO2 measurement range | : 400 ~ 5000 PPM |
CO2 measurement error range | : ± 50PPM ± 5% |
Pressure dependence | : + 1.6 % reading per kPa deviation from normal pressure |
CO2 measurement resolution and response time | : 1 PPM ; T90 < 120s |
Temperature range | : -5°C ~ 50°C or 23°F ~ 122°F |
Temperature measurement error range | : ± 0.5 or 0.9 |
Temperature measurement resolution/response time | : 0.1.1°C /°F; T90 < |
120sT90 < 120s
Humidity measurement resolution and response time| : 0.1% ; T90 < 600s.1% ;
T90 < 600s
Humidity measurement range| : 0.0% ~ 99.9%RH
Humidity measurement error range| : ± 5% RH
Backup battery running time| : ~12 Hours
Work environment| : Working temperature -5°C ~ 50°C
: Working humidity 0 ~ 90% RH (no condensation)
Storage environment| : Storage temperature -10°C ~ 60°C
: Storage humidity 0 ~ 95% RH (no condensation)
Sensor service life| : 10 years (end of product life: the display shows
“End”)
IP Rating| : IP40
Environmental protection standard| : RoHS
Overall dimensions| : 99 mm x 99 mm x 37 mm
Product weight| : Net weight 291gr
Service and Contact
For questions about the installation, use or operation of this product please visit www.resideo.com and use the search engine to find more information. Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
Symbols
When the unit has come to the end of its life, dispose of it in accordance with local regulations. It is classified as electronic waste and contains a battery and therefore should be disposed of separately from household waste.
CE compliance logo. This product is in conformity with the relevant European union harmonization legislation.
Disclaimer
This CO2 Monitor is designed to alert you to a potentially dangerous build-up of Carbon Dioxide gas. It is not designed to remedy a Carbon Dioxide problem nor to locate a specific source of Carbon Dioxide. Resideo shall not be liable to pay for any Carbon Dioxide investigation or service call carried out or arranged in response to an alarm.
Warranty
RESIDEO’S 10 YEAR WARRANTY POLICY
R100C-1, R200C-1, R200S-1, R200H-N1, R200ST-N1, R200C-N1, R200S-N1, R200C-2,
R200S-2, R200H-N2,
R200ST-N2 R200C-N2, R200S-N2, R200C2-A, R200C2-A-UK
Beneficiary of this Warranty
This limited warranty is provided to its direct customer (“Buyer”) by the
member of the Resideo Technologies, Inc group of companies (“Resideo”) which
sells the product. Resideo does not provide this warranty to the consumer or
end-user of the product. Resideo expects that Buyer will give its customers an
equivalent
warranty to that given by Resideo to Buyer hereunder. This does not affect any
statutory obligations that Resideo may have to consumers as manufacturer of
the Products. Resideo reserves the right, at its discretion, to change these
Warranty Terms and the products to which these Warranty Terms apply. Any
changes to these Warranty Terms only apply to Products sold after the date of
the change.
Resideo’s Warranty
Resideo warrants that the Products will be free from defective materials and
faulty workmanship and conform to applicable specifications for a period of
120 months from the manufacturing date code on the Product. If any Product
becomes defective during the applicable warranty period for a reason that is
not excluded below, Resideo will, at its sole option, either repair or replace
free of charge with a new or re-furbished product, or credit to Buyer’s
account the price paid for the Product.
Resideo will not be responsible for any of Buyer’s costs of de-installing and
re-installing the Product, travel or any other costs.
Exclusions from the Warranty
This warranty is an extended manufacturer’s warranty and to the extent
permitted by law, is in lieu of all other warranties and conditions, expressed
or implied including those of satisfactory quality or fitness for a particular
purpose. Resideo shall have no obligation under this warranty or otherwise if:
i) The product is not installed in accordance with Resideo’s installation
instructions and applicable installation standards, is not used for a purpose
for which it is designed and in accordance with Resideo’s user instructions or
is not maintained in accordance with Resideo’s care and maintenance
instructions or is altered (including the alteration of any serial number),
serviced or repaired by anyone other than Resideo/Resideo’s Authorized
Service/Repair Centre: ii) Damage is caused by outside
occurrences, such as lightning, power surges, fire, floods, acts of nature, or
the like or quality of water, or is caused by misuse, or vandalism; or iii) A
defect is not caused by reason of defective materials or workmanship. iv) This
warranty does not cover the re-changeable battery used in R200C2-A &
R200C2-A-UK. This warranty does not cover the costs of replacing consumable
items (such as batteries), maintenance checks and adjustments, such as Product
calibration, which may
be required in accordance with the Product use and maintenance instructions.
Returns and Repairs
Prior to returning any Product that has become defective during the applicable
warranty period for a reason that is not excluded under these Warranty Terms,
Buyer must contact Resideo customer service to obtain a return merchandise
authorization (RMA) number. To obtain the RMA number, Buyer must provide: i)
Product model number and serial number, ii) Proof of purchase, iii)
Description of the defect. Buyer shall send the defective Product to Resideo
at its own expense, appropriately packaged to prevent damage to the Product,
together with the RMA and proof of purchase, in accordance with the
instructions of the Resideo customer service representative. Resideo will test
the returned Product to verify that it is defective. At Resideo’s request
Buyer shall provide such additional information as Resideo may reasonably
require to verify the cause of the defect, including date and location of
installation, Product application, manner of operation, maintenance records
and failure mode. If Resideo determines that the Product is defective, Resideo
will decide whether to repair or replace the Product or credit the Product
purchase price to Buyer’s account. If Resideo decides to replace the Product,
Resideo will send the replacement Product to Buyer at Resideo’s expense.
Unless otherwise agreed in writing, Resideo will destroy any Product that it
determines to be defective. If Resideo does not find the Product defective,
Resideo reserves the right to charge the Buyer for the reasonable costs of its
investigation of the alleged defect. If Buyer pays Resideo in advance for the
costs of returning the Product, Resideo will send the non-defective Product
back to Buyer but otherwise Resideo will destroy the Product.
Out of Warranty Repairs
At the request of Buyer, Resideo will provide to Buyer a quotation for the
costs to repair any Product outside of the applicable warranty period, if
Resideo considers such Product to be repairable. If Buyer accepts the
quotation and sends the Product to Resideo (following the same process as for
in-warranty returns), Resideo will repair the Product in accordance with the
quotation and return the repaired Product to Buyer. The repaired Product will
be warranted for 90 days from the date of repair.
Miscellaneous
If any part of these Warranty Terms is prohibited by applicable laws, the
relevant part shall be null and void, but the remainder of the Warranty Terms
shall remain in full force and effect.
www.resideo.com
Security Communications SAS
1198 Avenue Maurice Donat
06250 Mougins, France
© 2021 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>