GE current ML900 Arize Factor Installation Guide

June 9, 2024
GE current

Arize ® Factor ML900
High power for high-density cultivators

GE current ML900 Arize Factor

ML900 Arize Factor

Optimized Scalable Powerful Assembled in the USA

Three broad light spectrums optimize growth at every stage, from vegetative to flower.| Maximize production in
both single- and multilayer facilities with the Factor’s multiple rack
mounting options| Each ML900 array produces an average
1,050 μmol/m²/s over a
4’ x 4’ area at 2.8 μmol/J| Trusted manufacturing, a standard five-year warranty and a >50,000
hour lifetime ensure consistent, predictable yields for years to come

www.led.com for the latest in lighting innovations from the inventors of the LED

Spectra

GE current ML900 Arize Factor - 1

Spectrum table

Spectrum Typical Photon Flux¹ (μmol/s) Power² (W) Efficacy² (μmol/J)
PKR 1741 639 2.7
PKB 1695 626 2.7
PKF 1729 626 2.8
BRI 1448 638 2.3
BRV 1404 632 2.3

Spectrum Photon Distribution

Ratio| Blue PF| Green PF| Red PF| Far Red PF
PKR| 8%| 15%| 77%| 0%
PKB| 16%| 15%| 69%| 0%
PKF| 8%| 15%| 72%| 5%
BRI| 15%| 38%| 47%| 0%
BRV| 25%| 38%| 37%| 0%

¹ Typical PPF +/-10%
² Tested at maximum input voltage of 480VAC
Why Factor?

GE current ML900 Arize Factor - 2

  1. Rolling rack mount
    Factor adapts to your grow, not the other way around. The system can be installed on the side of a grow cart using the transversal bar, allowing it to fit below ventilation  systems.

  2. Suspended mount
    One size fits all. Straightforward hooks allow the light bars to be hung from any rack, and the power supply can be remotely mounted, meaning the Factor can be used in any setup.

  3. Reliability
    We perform the most extensive, stringent testing in the industry. We test the LED, water and dust ingress protection, subsystem and complete system at our in-house and independent laboratories around the world. Validation of our designs, components, products and processes include high temperature, high humidity and accelerated life testing.GE current ML900 Arize Factor -
3

  4. Do more with less
    Compared to multi-bar arrays, the Factor maintains or exceeds PPFD levels over a 4’ x 4’ area using only two bars per array, lowering capital and operating expenses.

GE current ML900 Arize Factor - 4

Mechanical outline

GE current ML900 Arize Factor - 5

Dimensions and weight

| Length| Width| Height| Weight
Fixture| 46.97”   1193 mm| 3.58”  91 mm| 2.08”   53 mm| 5.7 lbs  2.6 kg
Power supply| 10.81”   274.5 mm| 9.96”   252.9 mm| 3.65”   92.8 mm| 7.7 lbs 3.5 kg

Specifications

Dimming range 0-10V
Max source current 450uA
Dim-to-off Yes
Dim off voltage 0.35-0.65 V (typ. 0.5 V)
Dim on voltage 0.55-0.85 V (typ. 0.7 V)
Dimming output range 10%-100%
Absolute maximum dimming voltage 20V

For input voltage option 3, dimming control input is non-isolated from Class 1 driver output circuit.
Use with sink dimmers only

Power factor >0.9
Max. remote mount distance 6 ft (1.83 m)
Cooling Passive
Light distribution 140°
Operating environment 0°C to 30°C (32°F to 86°F)
IP rating IP65
Lifetime L90: >50,000 hours¹

¹ Tested at 30°C per TM-21

Order code table

GE current ML900 Arize Factor - 6

Product ID| Model| Mounting| Spectrum| Input voltage| Distribution| Options| Gen
---|---|---|---|---|---|---|---
GEHF| H2 = 2x high output bars, 1x 600W driver| R = Rolling rack| PKR| 2 = 120-277V (UL)| W = Wide batwing| X = None| 1
S = Suspended| PKB| 5 = NEMA 5- 5P
| PKF| 3 = 277-480V (UL)| 6 = NEMA 6- 5P

| BRI| 7 = NEMA L7-15P
| BRV| |

* Only available with input voltage option 2
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are
trademarks of the General Electric Company and are used under license. Information provided
is subject to change without notice. All values are design or typical values when measured
under laboratory conditions.
www.LED.com | HORT146 (Rev. 04/08/2022)