GE current ML900 Arize Factor Installation Guide
- June 9, 2024
- GE current
Table of Contents
Arize ® Factor ML900
High power for high-density cultivators
ML900 Arize Factor
Optimized | Scalable | Powerful | Assembled in the USA |
---|
Three broad light spectrums optimize growth at every stage, from vegetative to
flower.| Maximize production in
both single- and multilayer facilities with the Factor’s multiple rack
mounting options| Each ML900 array produces an average
1,050 μmol/m²/s over a
4’ x 4’ area at 2.8 μmol/J| Trusted manufacturing, a standard five-year
warranty and a >50,000
hour lifetime ensure consistent, predictable yields for years to come
www.led.com for the latest in lighting innovations from the inventors of the LED
Spectra
Spectrum table
Spectrum | Typical Photon Flux¹ (μmol/s) | Power² (W) | Efficacy² (μmol/J) |
---|---|---|---|
PKR | 1741 | 639 | 2.7 |
PKB | 1695 | 626 | 2.7 |
PKF | 1729 | 626 | 2.8 |
BRI | 1448 | 638 | 2.3 |
BRV | 1404 | 632 | 2.3 |
Spectrum Photon Distribution
Ratio| Blue PF| Green PF| Red PF| Far Red PF
PKR| 8%| 15%| 77%| 0%
PKB| 16%| 15%| 69%| 0%
PKF| 8%| 15%| 72%| 5%
BRI| 15%| 38%| 47%| 0%
BRV| 25%| 38%| 37%| 0%
¹ Typical PPF +/-10%
² Tested at maximum input voltage of 480VAC
Why Factor?
-
Rolling rack mount
Factor adapts to your grow, not the other way around. The system can be installed on the side of a grow cart using the transversal bar, allowing it to fit below ventilation systems. -
Suspended mount
One size fits all. Straightforward hooks allow the light bars to be hung from any rack, and the power supply can be remotely mounted, meaning the Factor can be used in any setup. -
Reliability
We perform the most extensive, stringent testing in the industry. We test the LED, water and dust ingress protection, subsystem and complete system at our in-house and independent laboratories around the world. Validation of our designs, components, products and processes include high temperature, high humidity and accelerated life testing. -
Do more with less
Compared to multi-bar arrays, the Factor maintains or exceeds PPFD levels over a 4’ x 4’ area using only two bars per array, lowering capital and operating expenses.
Mechanical outline
Dimensions and weight
| Length| Width| Height| Weight
Fixture| 46.97” 1193 mm| 3.58” 91 mm| 2.08” 53 mm| 5.7 lbs 2.6 kg
Power supply| 10.81” 274.5 mm| 9.96” 252.9 mm| 3.65” 92.8 mm| 7.7 lbs
3.5 kg
Specifications
Dimming range | 0-10V |
---|---|
Max source current | 450uA |
Dim-to-off | Yes |
Dim off voltage | 0.35-0.65 V (typ. 0.5 V) |
Dim on voltage | 0.55-0.85 V (typ. 0.7 V) |
Dimming output range | 10%-100% |
Absolute maximum dimming voltage | 20V |
For input voltage option 3, dimming control input is non-isolated from Class 1
driver output circuit.
Use with sink dimmers only
Power factor | >0.9 |
---|---|
Max. remote mount distance | 6 ft (1.83 m) |
Cooling | Passive |
Light distribution | 140° |
Operating environment | 0°C to 30°C (32°F to 86°F) |
IP rating | IP65 |
Lifetime | L90: >50,000 hours¹ |
¹ Tested at 30°C per TM-21
Order code table
Product ID| Model| Mounting| Spectrum| Input voltage|
Distribution| Options| Gen
---|---|---|---|---|---|---|---
GEHF| H2 = 2x high output bars, 1x 600W driver| R = Rolling rack| PKR| 2 =
120-277V (UL)| W = Wide batwing| X = None| 1
S = Suspended| PKB| 5 = NEMA 5- 5P
| PKF| 3 = 277-480V (UL)| 6 = NEMA 6- 5P
| BRI| 7 = NEMA L7-15P
| BRV| |
* Only available with input voltage option 2
© 2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE
monogram are
trademarks of the General Electric Company and are used under license.
Information provided
is subject to change without notice. All values are design or typical
values when measured
under laboratory conditions.
www.LED.com | HORT146 (Rev. 04/08/2022)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>