GAGGENAU DSZ1WW1J1 BSH Hausgeräte Long Life Recirculation Set Instructions
- June 9, 2024
- Gaggenau
Table of Contents
DSZ1WW1J1 BSH Hausgeräte Long Life Recirculation
Set Instructions
DSZ1WW1J1 BSH Hausgeräte Long Life Recirculation Set
**** General information
- Read this instruction manual carefully.
- Keep the instruction manual and the product information safe for future reference or for the next owner.
- The appliance can only be used safely if it is correctly installed according to the safety instructions. The installer is responsible for ensuring that the appliance works perfectly at its installation location.
- This instruction manual is intended for the installer of the optional accessory.
- Only a licensed expert may connect the appliance.
- Switch off the power supply before carrying out any work.
Safe installation
Observe the safety instructions when installing the optional accessory.
WARNING ‒ Risk of suffocation!
Children may put packaging material over their heads or wrap themselves up in
it and suffocate.
▶ Keep packaging material away from children.
▶ Do not let children play with packaging material.
WARNING ‒ Risk of injury!
Components inside the appliance may have sharp edges.
▶ Wear protective gloves.
The odour filter remains hot for quite some time after it has been
regenerated.
▶ Do not touch the odour filter straight after it has been regenerated – allow
it to cool down.
Included with the appliance
After unpacking all parts, check for any damage in transit and completeness of
the delivery. → Fig. 1
Establishing the pipework
- Establish the pipework in such a way that the flexible hose is flush with the cabinet base. → Fig. 2
- For circulating-air mode, establish an air outlet in the unit’s front toe kick.
The air outlet must have a minimum cross section of approximately 400 cm². Make the outlet opening in the base panel as large as possible in order to keep draughts and noise to a minimum.
Regenerable odour filter
Odour filters bind odorous substances in circulatingair mode. Regularly
replaced or regenerated odour filters guarantee a high level of odour removal.
With normal use (daily for approx. one hour), replace the odour filter at
least every 10 years.
The regenerable odour filter can be regenerated in a standard oven.
With normal use (approx. 1 hour a day), the regenerable odour filter must be
replaced or regenerated every 3-4 months. The regenerable odour filter can be
regenerated up to 30 times.
Fitting odour filters
-
Press .
a The glass panel moves up to halfway upwards and grease filter cassettes are transported upwards. -
Remove the grease filter cassettes.
→ Fig. 3 -
Insert the odour filter cartridges.
→ Fig. 4 -
Insert the grease filter cartridges.
→ Fig. 5 -
Press .
The glass panel and the filter cartridges move downwards.
The appliance flap closes and the appliance switches off.
Cleaning the odour filter
ATTENTION!
Incorrect cleaning damages the regenerative odour filter.
▶ Observe the regeneration instructions.
▶ Never clean a regenerative odour filter with cleaning products, water, in
the dishwasher or with a wet cloth.
▶ If the regenerative odour filters are visibly soiled, remove the dirt with a
damp cloth before starting the regeneration process. Ensure that the odour
filter does not get wet.
Regenerating the odour filter
WARNING ‒ Risk of fire!
The oven cleaning function (pyrolytic self-clean) may cause a regenerable
odour filter to catch fire.
▶ Never regenerate a regenerable odour filter with the oven cleaning function
(pyrolytic self-clean).
WARNING ‒ Risk of injury!
The odour filter remains hot for quite some time after it has been
regenerated.
▶ Do not touch the odour filter straight after it has been regenerated – allow
it to cool down.
Note: During the regeneration process, parts of the odour filter may become
discoloured. This discolouration has no effect on the performance of the odour
filter.
Requirement: The odour filter is removed.
- Preheat the oven to a maximum of 200 °C (air recirculation ).
- To ensure that you do not scratch the baking tray, place the odour filter on a wire rack.
- During regeneration, an odour may develop. Open a window to ensure that the room is well ventilated.
- Regenerate the regenerative odour filter with the following settings.
Duration | Temperature | Type of heating |
---|---|---|
120 mins | Max. 200 °C | Air recirculation |
5. Leave the hot odour filter to cool down on a heatresistant surface.