Operating instructions
PM 4-M
PM 4-M Multi-Line and Point Laser
It is essential that the operating instructions are read before the tool is
operated for the first time.
Always keep these operating instructions together with the tool.
Ensure that the operating instructions are with the tool when it is given to
other persons.
These numbers refer to the illustrations. You can find the illustrations at
the beginning of the operating instructions.
In these operating instructions, the designation “the tool” always refers to
the PM 4-M multi-line laser.
Parts, operating controls and indicators 1
- On/off button with LED
- Rotary knob for pendulum locking mechanism
- Laser exit window
- Fine adjustment for rotation platform
- Adjustable foot
- Circular bubble level
- Battery compartment
General information
1.1 Safety notices and their meaning
DANGER
Draws attention to imminent danger that will lead to
seriousbodilyinjuryorfatality.
WARNING
Draws attention to a potentially dangerous situation that could lead to
serious personal injury or fatality.
CAUTION
Draws attention to a potentially dangerous situation that could lead to slight
personal injury or damage to the equipment or other property.
NOTE
Draws attention to an instruction or other useful information.
1.2 Explanation of the pictograms and other information
Warning signs
General warning
Obligation signs
Read the operating instructions before use.
Symbols
** Disposal of power tools or appliances and batteries together with
household waste is not permissible.
On the tool
CAUTION
LASER RADIATION – DO NOT STARE INTO BEAM
620-690nm/0.95mW max.
CLASS II LASER PRODUCT** Do not stare into the beam.
Laser warning plates for the USA in accordance with CFR 21 § 1040 (FDA). On
the tool
Laser radiation. Do not look into the beam. Laser class 2.
Laser warning plates based on IEC 60825-
1/EN 60825‑1:2007
Location of identification data on the tool
The type designation and serial number can be found on
thetypeidentificationplateonthetool.Makeanoteof this data in your operating
instructions and always refer to it when making an enquiry to your Hilti
representative or service department.
Type:——————
Generation: 01——————–
Serial no.:———————
Description
2.1 Use of the product as directed
The PM 4-M is a self-leveling multi-line laser which allows a single person to
transfer right angles, level horizontally and carry out alignment work, and
plumb accurately. The tool has three lines (one horizontal and two vertical),
a reference point at the bottom as well as four points of line intersection
(front, top, left and right) with a range of approx. 10 m.
The range is dependent on the brightness of ambient light.
The tool is designed for mainly indoor use and is no substitute for a
rotatinglaser.
When used for outdoor applications, care must be taken to ensure that the
general conditions are similar to those encountered indoors. Possible
applications are:
Marking the position of partition walls (at right angles and in the
verticalplane).
Checking and transferring right angles.
Aligning components to be installed or sections of a structure in three axes.
Transferring points marked on the floor to the ceiling.
The laser lines can be switched on both separately (vertical or horizontal
line only) and together. When used with inclination angle, the pendulum for
automatic leveling is blocked.
Observe the information printed in the operating instructions concerning
operation, care and maintenance.
Modification of the tool is not permissible.
To avoid the risk of injury, use only genuine Hilti accessories and insert
tools.
The tool and its ancillary equipment may present hazards when used incorrectly
by untrained personnel or when used not as directed.
2.2 Features
The PM 4-M levels itself automatically within a range of approx. 4°. If this
is not sufficient, the tool can be leveled using the adjustable feet and
circular bubble level.
Self-leveling takes only approx. 3 seconds.
The multi-line laser gives an “Out of self-leveling range” warning when the
self-leveling range is exceeded (the laser beams blink).
The PM 4-M is easy to set up and operate and features a rugged plastic
housing.
The tool can be used together with the PMA 31 laser receiver.
In the normal operating mode, the tool switches itself off after 1 hour.
Sustained operating mode can be activated by pressing and holding the on/off
button for four seconds.
2.3 Items supplied with the toolbox version
- 1 Multi-line laser
- 1 Tripod adapter
- 4Batteries
- 1 Operating instructions
- 1 Manufacturer’s certificate
2.4 Information displayed during operation
LED | The LED does not light. | The tool is switched off. |
---|---|---|
The LED does not light. | The batteries are exhausted. | |
The LED does not light. | The batteries are inserted incorrectly. | |
The LED lights constantly. | The laser beam is switched on. The tool is in |
operation.
The LED blinks twice every 10 seconds (pendulum not locked) or every 2 seconds
(pendulum locked).| The batteries are almost exhausted.
The LED blinks.| The tool is switched off but the pendulum is not locked.
Laser beam| The laser beam blinks twice every 10 seconds (pendulum not locked)
or every 2 seconds (pendulum locked).| The batteries are almost exhausted.
The laser beam blinks five times and then remains permanently on.| Automatic
power-off has been deactivated.
The laser beam blinks rapidly.| The tool is unable to level itself (outside
the self-leveling range).
The laser beam blinks every 2 seconds.| Inclined line operating mode. The
pendulum is locked, as a result of which the lines are not leveled.
Accessories
Designation | Short designation | Description |
---|---|---|
Tripod | PMA 20 | |
Target plate | PMA 54/55 | |
Target plate | PRA 50/51 | |
Laser receiver | PMA 31 | |
Hilti toolbox | ||
Laser visibility glasses | PUA 60 | The laser visibility glasses are not |
protective glasses and thus do not
protect the eyes from laser beams. As the laser visibility glasses restrict
color vision, they should be worn only when working with the PM 4-M laser
tool. Do not wear the laser visibility glasses while driving a vehicle on a
public road.
Technical data
Right of technical changes reserved.
Range of the lines and intersection point| without laser receiver: 10 m (33
ft) with laser receiver: 50 m (164 ft)
---|---
Accuracy’| ±2 mm at 10 m (±0.08 in at 33 ft)
Self-leveling time| 3 s
Laser class| Class 2, visible, 635 nm, ±10 nm (EN 60825-3:2007 / IEC 60825 –
3:2007); class II (CFR 21 §1040 (FDA)
Line width| Distance 5 m: < 2.2 mm
Self-leveling range| ±4° (typical)
Automatic power-off| Activated after: 1 h
Operating status indicator| LED and laser beams
Power supply| AA-size batteries, Alkaline batteries: 4
Operating time (all lines on)| Alkaline battery 2,500 mAh, Temperature +24°C
(72 °F): 7 h (typical)
Operating temperature| Min. -10°C / Max. +50°C (+14 to 122 °F)
Storage temperature| Min. -25°C / Max. +63°C (-13 to 145 °F)
Dust and water spray protection (except battery com- partment)| IP 54 as per
IEC 60529
Tripod thread (tripod adaptor)| BSW 5/8″UNC1/4″
Weight| Including battery: 990 g (2.18 Ibs)
Dimensions| 124 x 124 x 187 mm (4’/8 x 4 7/8 x 7 3/8 in)
1 Influences such as particularly high temperature fluctuations, dampness,
shock, dropping, etc. can affect accuracy. Unless stated otherwise, the tool
was adjusted or calibrated under standard ambient conditions (MIL-STD-810F).
Safety instructions
WARNING: Ensure that you read all safety precautions and instructions.Failure to observe the safety precautions and instructions may result in electric shock, fire and/or serious injury. Retain all safety precautions and instructions for future reference. .
5.1 General safety measures
a) Check the accuracy of the tool before using it to take measurements.
b) The tool and its ancillary equipment may present hazards when used
incorrectly by untrained personnel or when used not as directed.
c) To avoid the risk of injury, use only genuine Hilti accessories and
additional equipment.
d) Stay alert, watch what you are doing and use common sense when operating
the machine. Don’t use the machine when you are tired or under the influence
of drugs, alcohol or medication. Amoment of inattention while operating
machines may result in serious personal injury.
e) Modification of the tool is not permissible.
f) Observe the information printed in the operating instructions concerning
operation, care and maintenance.
g) Do not render safety devices ineffective and do not remove information and
warning notices.
h) Keep children and other persons away from the area while the tool or
appliance is in use.
i) Take the influences of the surrounding area into account. Do not expose the
tool to rain or snow anddonotuseitindamporwetconditions.Do not use the tool
where there is a risk of fire or explosion.
j) Maintain the machine carefully. Check for misalignment or binding of moving
parts, breakage of parts and any other condition that may affect the machine’s
operation. If damaged, have the machine repaired before use. Poor maintenance
is the cause of many accidents.
k) Maintain the machine carefully. Check for misalignment or binding of moving
parts, breakage of parts and any other condition that may affect the machine’s
operation. If damaged, have the machine repaired before use. Poor maintenance
is the cause of many accidents.
l) Have your power tool serviced by a qualified repair person using only
identical replacement parts.
This will ensure that the safety of the power tool is maintained.
m) The user must check the accuracy of the tool after it has been dropped or
subjected to other mechanical stresses.
n) When the tool is brought into a warm environment from very cold conditions,
or vice-versa, allow it to become acclimatized before use.
o) Make sure that the tool is mounted securely when adapters or accessories
are used.
p) Keep the laser exit aperture clean to avoid measurement errors.
q) Although the tool is designed for the tough conditions of jobsite use, as
with other optical and electronic instruments (e.g. binoculars, spectacles,
cameras) it should be treated with care.
r) Although the tool is protected to prevent entry of dampness, it should be
wiped dry each time before being put away in its transport container.
s) Check the accuracy of the measurements several times during use of the
tool.
5.2 Proper organization of the workplace
a) Secure the area in which you are working and take care to avoid directing
the beam towards other persons or towards yourself when setting up the tool.
b) Avoid unfavorable body positions when working from ladders. Make sure you
work from a safe stance and stay in balance at all times.
c) Measurements taken through panes of glass or other objects may be
inaccurate.
d) Ensure that the tool is set up on a steady, level surface (not subject to
vibration).
e) Use the tool only within its specified limits.
f) If several laser tools are used in the same working area, care must be
taken to avoid confusing the beams.
g) Magnetic fields may affect the accuracy of the tool. It must thus be kept
away from magnetic objects. The tool is not affected by the Hilti universal
adapter.
h) When working with the receiver, it must be held exactly at right angles to
the laser beam.
i) Do not use the tool in the proximity of medical instruments.
5.3 Electromagnetic compatibility
Although the tool complies with the strict requirements of the applicable
directives, Hilti cannot entirely rule out the possibility of the tool being
subject to interference caused by powerful electromagnetic radiation, leading
to incorrect operation. Check the accuracy of the tool by taking measurements
by other means when working under such conditions or if you are unsure.
Likewise, Hilti cannot rule out the possibility of interference with other
devices (e.g. aircraft navigation equipment).
5.4 Laser classification for laser class 2/class II tools
Depending on the version purchased, the tool complies with Laser Class 2 in
accordance with IEC825-1:2007/EN60825-1:2007 and Class II in accordance with
CFR 21 § 1040 (FDA). This tool may be used without need for further protective
measures. The eyelid closure reflex protects the eyes when a person looks into
the beam unintentionally for a brief moment. This eyelid closure reflex,
however, may be negatively affected by medicines, alcohol or drugs.
Nevertheless, as with the sun, one should not look directly into sources of
bright light. Do not direct the laser beam toward persons.
5.5 Electrical
a) Insulate or remove the batteries before shipping the tool.
b) To avoid pollution of the environment, the tool must be disposed of in
accordance with the currently applicable national regulations. Consult the
manufacturer if you are unsure of how to proceed.
c) Keep the batteries out of reach of children.
d) Do not allow the batteries to overheat and do not expose them to fire. The
batteries may explode or release toxic substances.
e) Do not charge the batteries.
f) Do not solder the batteries into the tool.
g) Do not discharge the batteries by short circuiting as this may cause them
to overheat and present a risk of personal injury (burns).
h) Do not attempt to open the batteries and do not subject them to excessive
mechanical stress.
i) Do not use damaged batteries.
j) Do not mix old and new batteries. Do not mix batteries of different makes
or types.
5.6 Liquids
Under abusive conditions, liquid may leak from the battery. Avoid contact. If
contact accidentally occurs, flush with water. In the event of the liquid
coming into contact with the eyes, rinse the eyes with plenty of water and
consult a doctor. Liquid ejected from the battery may cause irritation or
burns.
Before use
6.1 Inserting the batteries 2
DANGER
Use only new batteries.
-
Open the battery compartment.
-
Remove the batteries from the packaging and insert them in the tool.
NOTE Only batteries recommended by Hilti may be used to power the tool. -
Check that the battery terminals are positioned correctly as shown on the underside of the unit.
-
Close the battery compartment. Check that the catch engages properly.
Operation
NOTE
To achieve maximum accuracy, project the line onto a vertical, flat surface.
When doing so, set up the tool at 90° to the surface.
7.1 Operation
7.1.1 Switching the laser beams on
- Unlock the pendulum.
- Press the on/off button once or repeatedly until the desired operating mode is set.
NOTE
The tool switches between the operating modes according to the sequence shown below and then starts again from the beginning provided that the on/off button is pressed again within 5 seconds each time.
Vertical laser lines
Horizontal laser line
Vertical and horizontal laser lines
7.1.2 Switching the tool/laser beams off
Press the on/off button until the laser beam is no longer visible and the LED
goes out.
NOTE
- The tool can be switched off if the on/off button has not previously been pressed for at least 5 seconds.
- The tool switches itself off automatically after approx. 1hour.
7.1.3 Deactivating the automatic power-off feature
Press and hold the on/off button for approx. 4 sec. until the laser beam
blinks five times as confirmation.
NOTE
The tool will be switched off when the on/off button is pressed or when the
batteries are exhausted.
7.1.4 Inclined line function
Lock the pendulum.
The tool does not level itself automatically.
The laser beam(s) blink(s) every two seconds.
7.1.5 Using the tool with the PMA 31 laser receiver
For further information, please refer to the PMA 31 operating instructions.
7.2 Examples of applications
NOTE
Theadjustablefeetmakeitpossibletopre-levelthetool approximately on a very
unlevel substrate.
7.2.1 Transferring heights 3
7.2.2 Setting out drywall track for a partition wall 45
7.2.3 Aligning pipes vertically 6
7.2.4 Aligning radiators 7
7.2.5 Aligning door and window frames 8
7.3 Checking
7.3.1 Checking the plumb point 9
-
Make a mark on the floor (a cross) in a high room (e.g. in a stairwell or hallway with a height of 5–10 m).
-
Place the tool on an even, level surface.
-
Unlock the pendulum and switch on the tool.
-
Position the tool with the lower beam on the center of the cross.
-
Mark the top point of intersection of the laser lines on the ceiling. Attach a piece of paper to the ceiling before making the mark.
-
Pivot the tool through 90°.
NOTE The lower plumb beam must remain on the center of the cross. -
Mark the top point of intersection of the laser lines on the ceiling.
-
Repeat the procedure after pivoting the tool through 180° and 270°.
NOTE The resulting 4 marks form a circle in which the intersection of the diagonals d1 (1-3) and d2 (2-4) marks the exact center of the plumb point. -
Calculate the accuracy as described in section 7.3.1.1.
7.3.1.1 Calculation of accuracy
The result (R) provided by this formula (RH = room height) refers to the tool’s accuracy “in mm at 10 m” (formula (1)). This result (R) should be within the specification for the tool(2mmat10m).
7.3.2 Checking the leveling of the horizontal laser beam 10
-
Place the tool on an even, level surface approx. 20 cm from the wall (A) with the laser beam directed toward the wall (A).
-
Mark the point of intersection of the laser lines on the wall (A) with a cross (1).
-
Pivot the whole tool through 180° without using the rotatable housing and mark the point of intersection of the laser lines with a cross (2) on the wall opposite (B).
-
Place the tool on an even, level surface approx. 20 cm from the wall (B) with the laser beam directed toward the wall (B).
-
Mark the point of intersection of the laser lines on the wall (B) with a cross (3).
-
Pivot the whole tool through 180° without using the rotatable housing and mark the point of intersection of the laser lines with a cross (4) on the wall opposite (A).
-
Measure the distances d1 between (1) and (4) and d2 between (2) and (3).
-
Mark the mid points of d1 and d2.
If the reference points 1 and 3 are located on different sides of the mid point, then subtract d2 from d1.
If the reference points 1 and 3 are located on the same side of the mid point, then add d1 and d2 together. -
Divide the result by twice the length of the room (room length x 2).
The maximum permissible error is 2 mm.
7.3.3 Checking perpendicularity (horizontal) 11 12 13
-
Position the tool with the lower plumb beam on the center of a reference cross in the middle of a room at a distance of approx. 5meters from the walls so that the center of the front vertical laser line lies exactly on the vertical line of the first target plate (a).
-
Attach a second target plate or sheet of paper (b) to the wall at the half-way position (as shown in the illustration). Mark the right-hand point of intersection of the laser lines (d1).
-
Pivot the tool clockwise through exactly 90° (as seen from above). The reference point must remain in the center of the reference cross and the left-hand point of intersection of the laser lines must lie exactly on the vertical line of the target plate (a).
-
Mark the right-hand point of intersection of the laser lines (d2) on the target plate (c).
-
Then mark the center point (d3) of the front point of intersection of the laser lines on the target plate (b).
NOTE The horizontal distance between d1 and d3 must be no greater than 2 mm at a working distance of 5 m. -
Pivot the tool clockwise through exactly 180° (as seen from above). The reference point must remain in the center of the reference cross and the righthand point of intersection of the laser lines must lie exactly on the vertical line of the first target plate (a).
-
Then mark the left-hand point of intersection of the laser lines (d4) on the target plate (c).
NOTE The horizontal distance between d2 and d4 must be no greater than 2 mm at a working distance of 5 m.
NOTE If d3 is to the right of d1, the sum of the horizontal distances d1-d3 and d2-d4 must be no greater than 2 mm at a working distance of 5 m.
NOTE If d3 is to the left of d1,the difference between the horizontal distances d1-d3 and d2-d4 must be no greater than 2 mm at a working distance of 5 m.
7.3.4 Checking the accuracy of the horizontal line 14 15
-
Placethetoolattheedgeofaroomwithalengthof at least 10 m.
NOTE The floor surface must be even and level. -
Switch on all laser beams.
-
Set up a target plate at a distance of at least 10m from the tool, so that the front point of intersection of the laser lines lies in the center of the target plate (d0) and the vertical line on the target plate runs exactly through the middle of the vertical laser line.
-
Mark the mid point of the lower plumb beam on the floor (reference cross).
-
Pivot the whole tool clockwise through 45° (as seen from above) without using the rotatable housing. The reference point must remain on the center of the reference cross.
-
Then mark the point (d1) on the target plate where the horizontal laser line strikes the vertical line on the target plate.
-
Pivot the whole tool anti-clockwise through 90° (as seen from above) without using the rotatable housing. The reference point must remain on the center of the reference cross.
-
Then mark the point (d2) on the target plate where the horizontal laser line strikes the vertical line on the target plate.
-
Measure the following vertical distances: d0-d1, d0d2 and d1-d2.
NOTE The greatest measured vertical distance must be no more than 4 mm at a working distance of 10 m.
7.3.5 Checking the vertical lines 16
- Position the tool at a height of 2 meters.
- Switch the tool on.
- Position the first target plate T1 (vertical) at a distance of 2.5 meters from the tool at the same height (2 meters), so that the vertical laser beam strikes the plate. Mark this position.
- Then place the second target plate T2 at a position 2 meters below the first target plate, so that the vertical laser beam strikes the plate. Mark this position.
- Mark position 2 at the opposite side of the test setup (mirror image) on the laser line on the floor at a distance of 5 meters from the tool.
- Now place the tool on the floor on the mark for position 2 which you have just made. Direct the laser beam toward the target plates T1 and T2 so that it strikes the plates close to their center lines.
- Read the distances D1 and D2 from each target plate (distance of the laser line from the center of the target plate) and calculate the difference (D = D1 -D2).
NOTE Take care to ensure that the target plates are parallel to each other and that they are in the same vertical plane. (Horizontal alignment may result in measurement error).
If the difference D is greater than 2mm, the tool must be returned to a Hilti repair center for adjustment.
Care and maintenance
8.1 Cleaning and drying
-
Blow dust off the glass.
-
Do not touch the glass with the fingers.
-
Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth slightly with pure alcohol or a little water.
NOTE Do not use any other liquids as these may damage the plastic components. -
Observe the temperature limits when storing your equipment. This is particularly important in winter/summer if the equipment is kept inside a motor vehicle (-25 °C to +63 °C/-13 °F to 145 °F).
8.2 Storage
Remove the appliance from its case if it has become wet. The tool, its
carrying case and accessories should be cleaned and dried (at maximum 63
°C/145 °F). Repack the equipment only once it has dried completely and then
store it in a dry place.
Check the accuracy of the equipment before it is used after a long period of
storage or transportation.
Remove the batteries from the appliance before storing it for a long period.
Leaking batteries may damage the appliance.
8.3 Transport
Use the Hilti toolbox or packaging of equivalent quality for transporting or
shipping your equipment.
DANGER
Always remove the batteries before shipping the tool.
8.4 Hilti calibration service
We recommend that the tool is checked by the Hilti calbration service at
regular intervals in order to verify its
reliability in accordance with standards and legal requirements. Use can be
made of the Hilti calibration service at any time, but checking at least once
a year is recommended.
The calibration service provides confirmation that the tool is in conformance,
on the day it is tested, with the specifications given in the operating
instructions.
The tool will be readjusted if deviations from the manufacturer’s
specification are found. After checking and adjustment, a calibration sticker
applied to the tool and a calibration certificate provide written verification
that the tool operates in accordance with the manufacturer’s specification.
Calibration certificates are always required by companies certified according
to ISO 900x.
Your local Hilti Center or representative will be pleased to provide further
information.
Troubleshooting
Fault | Possible cause | Remedy |
---|---|---|
The tool cannot be switched on. | The battery is exhausted. | Replace the |
battery.
The battery is inserted the wrong way round (incorrect polarity).| Insert the
battery correctly.
The battery compartment is not closed.| Close the battery compartment.
The tool or the on/off button is faulty.| If necessary, the power tool should
be repaired by Hilti Service.
Individual laser beams don’t function.| The laser source or laser control unit
is faulty.| If necessary, have the power tool re-paired by Hilti Service.
The tool can be switched on but no laser beam is visible.| The laser source or
laser control unit is faulty.| If necessary, have the power tool re-paired by
Hilti Service.
The temperature is too high or too low.| Allow the tool to cool down or warm
up.
Automatic leveling doesn’t func- tion.| The tool is set up on an excessively
inclined surface.| Set up the tool on the level.
The tilt sensor is faulty.| If necessary, have the power tool repaired by
Hilti Service.
Disposal
WARNING
Improper disposal of the equipment may have serious consequences:
The burning of plastic components generates toxic fumes which may present a
health hazard.
Batteries may explode if damaged or exposed to very high temperatures, causing
poisoning, burns, acid burns or environmental pollution.
Careless disposal may permit unauthorized and improper use of the equipment.
This may result in serious personal injury, injury to third parties and
pollution of the environment.
Most of the materials from which Hilti tools or appliances are manufactured
can be recycled. The materials must be correctly separated before they can be
recycled. In many countries, Hilti has already made arrangements for taking
back old tools and appliances for recycling. Ask Hilti customer service or
your Hilti representative for further information.
For EC countries only
Do not dispose of electronic measuring tools or appliances together with
household waste.
In observance of the European Directive on waste electrical and electronic
equipment and its implementation in accordance with national law, electrical
appliances that have reached the end of their life must be collected
separately and returned to an environmentally compatible recycling facility.
Dispose of the batteries in accordance with national regulations.
Manufacturer’s warranty – tools
Please contact your local Hilti representative if you have questions about the
warranty conditions.
FCC statement (applicable in USA)
CAUTION
This equipment has been tested and found to comply with the limits for a class
B digital device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and may radiate radio
frequency energy. Accordingly, if not installed and used in accordance with
the instructions, it may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Re-orient or relocate the receiving antenna.
- Increase the distance between the tool and receiver.
- Consult your dealer or an experienced TV/radio technician for assistance.
NOTE
Changes or modifications not expressly approved by Hilti may restrict the
user’s authorization to operate the equipment.
EC declaration of conformity (original)
Designation: | Multi-line laser |
---|---|
Type: | PM 4-M |
Generation: | 1 |
Year of design: | 2012 |
We declare, on our sole responsibility, that this product complies with the
following directives and standards: until 19th April 2016: 2004/108/EC, from
20th April 2016: 2014/30/EU, 2011/65/EU, EN ISO 12100.
Hilti Corporation, Feldkircherstrasse 100, FL‑9494 Schaan
|
---|---
Paolo Luccini
Head of BA Quality and Process Management
Business Area Electric Tools & Accessories
06/2015| Edward Przybylowicz
Head of BU Measuring Systems
BU Measuring Systems
06/2015
Technical documentation filed at:
Hilti Entwicklungsgesellschaft mbH
Zulassung Elektrowerkzeuge
Hiltistrasse 6
86916 Kaufering
Deutschland
EC Declaration of Conformity I UK Declaration of Conformity
PM 4-M (01)
Manufacturer:
Hilti Corporation
Feldkircherstraffe 100
9494 Schaan I Liechtenstein
Importer.
Hilti (Gt. Britain) Limited
1 Trafford Wharf Road, Old Trafford
Manchester, M17 113Y
Serial Numbers: 1-99999999999
2014/30/EU I Electromagnetic Compatibility Regulations 2016
2011/65/EU I The Restriction of the Use of Certain Hazardous Substances in
Electrical and Electronic Equipment Regulations 2012
EN 55022:2010 + AC:2011
EN 61010-1:2010
EN 61000-6-2:2005
Dr. Tahar Zrilli
Head of Quality and Process Management
Business Area Electric Tools & Accessories
Schaan. 13.07.2021
Tassilo Delmer
Executive Vice President
Business Unit Power Tools & Accessories
Hilti Corporation
LI-9494 Schaan
Tel.:+423 234 21 11
Fax:+423 234 29 65
www.hilti.grouphttps://hilti.to/ontrackapp