Please read this manual carefully and keep it for future reference.
Package Contents
Item | Quantity |
---|---|
Access Point | 1 |
Hose Clamp | 2 |
Mounting Plate Assembly | 1 |
M8 x 20 mm Screws | 6 |
M8 x 60 mm Expansion Anchors | 4 |
User Manual | 1 |
Warranty Manual | 1 |
Cable Gland for SFP Port | 1 |
Cable Gland for Ethernet Port (Pre-installed on the access point) | 1 |
SFP Port Plug (Pre-installed on the access point) | 1 |
Mounting Arm | 1 |
DC Connector Plug (Pre-installed on the access point) | 1 |
Cable Gland for DC Connector | 1 |
Grounding Cable | 1 |
Hardware Features
- 48 V DC Connector
- Ethernet/PoE Port
- Reset Hole
- SFP Port
PoE power supply: Connect one end of the Ethernet cable to the Ethernet/PoE
port of the access point, and the other end to a PoE-capable switch or other
power source equipment (PSE).
Local power supply: Connect the DC power adapter to the DC connector.
If you want to want to use a 1GE SFP transceiver, make sure the ambient
temperature meets the requirement of the SFP transceiver.
Technical Specifications
Item | Specification |
---|---|
Dimensions (W x D x H) | 300 mm × 300 mm × 75.5 mm (11.81 in. x 11.81 in. x |
2.97 in., without the mounting plate)
Data Rate| 2.4 GHz: 1148 Mbps
5 GHz: 4804 Mbps
Combined: 5952 Mpbs
Operating Radio| 802.11b/g/n/ax: 2.4 GHz to 2.4835 GHz
802.11a/n/ac/ax: 5.150 GHz to 5.350 GHz, 5.470 GHz to
5.725 GHz, 5.725 GHz to 5.850 GHz
Antenna| Built-in directional antenna
2.4 GHz: 50 degrees from the horizontal plane and 30 degrees from the vertical
plane
5 GHz: 60 degrees from the horizontal plane and 30 degrees from the vertical
plane
Service Ports| One 100/1000/2500Base-T Ethernet port, PoE-capable
One 1000Base-X SFP port (The 1GE SFP transceiver is optional.)
Restart/Factory
Reset| Supported
Status LED| One blue LED
Power Supply| There are three power supply modes available:
● Standard PoE: IEEE 802.3bt standard(PoE++), backward compatible with the
IEEE 802.3at standard(PoE+)
● 60W Passive PoE adapter (Optional accessory)
● Local power supply: 48 V DC /1 A
Note: The access point is not 802.3af(PoE)-compliant. (See Appendix for power
supply modes and respective data rates.)
Max. Power
Consumption| 40 W
Environment| Operating temperature: –40°C to +65°C (–40°F to +149°F)
Storage temperature: –40°C to +85°C (–40°F to +185°F)
Operating humidity: 0% to 100% RH (non-condensing)
Storage humidity: 0% to 100% RH (non-condensing)
≤ 3.5 kg (7.72 lbs., without the mounting plate)
Weight| ≤ 3.5 kg (7.72 lbs., without the mounting plate)
Color| Warm white
Installation Mode| Wall mounting and pole mounting
Note: You are advised to install the access point at a height ranging from 2.5
m to 3 m (98.43 in. to 118.11 in.) above the ground.
LED and Reset Hole
LED | Status | Description |
---|---|---|
Solid blue | The access point is operating normally with no alarms. | |
Off | The access point is not receiving power. | |
Slow blinking | The access point is operating normally but there is an alarm |
generated.
Fast blinking| Possible cases:
•Restoring the access point to factory settings.
•Upgrading the firmware.
•Handling alarms automatically.
•Starting up the access point.
Reset Hole| Press and hold the pin to the reset hole for less than 2 seconds.|
Restart the access point.
Press and hold the pin to the reset hole for more than 5 seconds.| Restore the
access point to factory settings.
Tools (Customer-Supplied)
1.6Installing the Mounting Arm
- Unfasten the four screws on the bottom and keep them handy.
- Wedge the mounting arm into the slot in the orientation noted by the arrow.
- Tighten the four screws using a Philips screwdriver.
Wall Mounting
- Drill four holes with a hole pattern of 65 mm x 110 mm (2.56 in. x 4.33 in.) on the wall.
- Attach the mounting plate assembly to a wall with its semicircle opening facing downward. Secure the mounting plate assembly using the M8 x 60 mm expansion anchors.
- Secure the access point with the mounting arm to the mounting plate assembly. Drive M8 x 20 mm screws into the holes noted by ②.
Vertical Pole Mounting
- Attach the mounting plate assembly to a vertical pole with its semicircle opening facing downward. Secure the mounting plate assembly by threading two hose clamps through the square holes on the mounting plate.
- Secure the access point with the mounting arm to the mounting plate assembly. Drive M8 x 20 mm screws into the holes noted by ②.
Horizontal Pole Mounting
- Attach the mounting plate assembly to a horizontal pole with its semicircle opening facing downward. Secure the mounting plate assembly by threading two hose clamps through the square holes on the mounting plate.
- Install the access point and the mounting arm to the mounting plate assembly. Drive M8 x 20 mm screws into the holes noted by ②.
Adjusting Orientation
You are advised to mount the access point vertically. The orientation is adjustable.
- Side-tilt angles: The access point allows for left and right side-tilt angles of 0°, 17°, and 34°. After orienting the access point to the desired angle, drive M8 x 20 mm screws into the holes noted by ③.
- Downtilt and uptilt angles: The access point allows for downtilt and uptilt angles of 0°, 25°, 50° and 90°. After orienting the access point to the desired angle, drive M8 x 20 mm screws into the holes noted by ④.
1.11Installing the Ethernet Cable
- A cable gland assembly includes four components: A (adapter base), B (split gasket), C (grommet), and D (compression cap).
- Insert the unterminated end of an Ethernet cable through part D, C, B, and A in sequence. Install an RJ-45 connector on the unterminated end of the Ethernet cable. Carefully insert the RJ-45 connector into the Ethernet port of the access point. Thread A (adapter base) into the Ethernet port. Slide B (split gasket) and C (grommet) along the cable, pressing firmly to seat B (gasket) completely into C (grommet).
- Tighten D (compression cap) until C (grommet) and B (gasket) compress on to the cable and provide cable strain relief. Use a waterproof tape to tighten the cable gland.
Note
- The waterproof tape is not included in the package contents.
- If you want to use an SFP transceiver (optional accessory), the cable gland can only hold the LC to LC fiber-optic cable with a diameter ranging from 2.8 mm to 3.2 mm (0.11 in. to 0.13 in.).
- When removing the cable gland, proceed in the reverse order of the installation. Start by loosening D (compression cap). Otherwise, the Ethernet cable may be damaged.
Configuring the Access Point
Method 1: App-based Configuration
Scan the QR-code in the manual or on the device to download Ruijie Cloud App.
Find First time use Ruijie Cloud? and follow the guide on App to configure the
network.
Method 2: Web-based Configuration
- Connect the access point to the SSID. If multiple devices exist in the network, use SSID @Ruijie-mXXXX. If only one device exists in the network, use SSID @Ruijie- sXXXX. You can also create a wired connection by connecting your PC to the LAN port of the access point with an Ethernet cable.
- Access http://10.44.77.253 (recommended) or http://192.168.120.1 (if there is no other gateway on the network) by browser.
- Click Start Setup to create network projects.
Caution
The access point has no default password. No password is required upon first
login.
For safety concerns, you are advised to configure a password after login and
change the password regularly.
Appendix
Table 1-1 Power Supply Modes
Power Input| Standard PoE: IEEE 802.3bt standard, backward compatible with the
IEEE 802.3at standard
---|---
Local power supply: 48 V DC/1 A
Power Supply Mode| 2.4 GHz| 5 GHz| Data Rate| Max. Power Consumption
IEEE 802.3bt Standard (Recommended)| 4 x 4| 4 x 4| 5952 Mbps| 40 W
60 W Passive PoE Adapter (Recommended)| 4 x 4| 4 x 4| 5952 Mbps| 40 W
Local Power Supply (48 V DC /1 A)| 4 x 4| 4 x 4| 5952 Mbps| 40 W
IEEE 802.3at Standard| 2 x 2| 2 x 2| 2976 Mbps| 25 W
Note: The 60 W Passive PoE Adapter is an optional accessory. The access point is not 802.3af-compliant.