SAFETY INSTRUCTIONS

ATTENTION:

| This product is certified in accordance with European Community (EC) safety standards.
---|---
| This product complies with Directive 2011/65/EU of the
European Parliament and of the Council, of 8 June 2011, on the restriction of the use of certain hazardous substances in electrical and electronic equipment and with Delegated Directive (EU) 2015/863 from Commission.

| (Applicable in countries with recycling systems).
This marking on the product or literature indicates that the product and electronic accessories (eg. Charger, USB cable, electronic material, controls, etc.) should not be disposed of as other household waste at the end of its useful life. To avoid possible harm to the environment or human health resulting from the uncontrolled disposal of waste, separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources. Home users should contact the dealer where they purchased this product or the National Environment Agency for details on where and how they can take these items for environmentally safe recycling. Business users should contact their vendor and check the terms and conditions of the purchase agreement. This product and its electronic accessories should not be mixed with other commercial waste.
| This marking indicates that the product and electronic accessories (eg. charger, USB cable, electronic material, controls, etc.) are susceptible to electric shock by direct or indirect contact with electricity. Be cautious when handling the product and observe all safety procedures in this manual.

GENERAL WARNINGS
  • This manual contains very important safety and usage information. very important. Read all instructions carefully before beginning the installation/usage procedures and keep this manual in a safe place that it can be consulted whenever necessary.
  • This product is intended for use only as described in this manual. Any other enforcement or operation that is not mentioned is expressly prohibited, as it may damage the product and put people at risk causing serious injuries.
  • This manual is intended firstly for specialized technicians, and does not invalidate the user’s responsibility to read the “User Norms” section in order to ensure the correct functioning of the product.
  • The installation and repair of this product may be done by qualified and specialized technicians, to assure every procedure are carried out in accordance with applicable rules and norms. Nonprofessional and inexperienced users are expressly prohibited of taking any action, unless explicitly requested by specialized technicians to do so.
  • Installations must be frequently inspected for unbalance and the wear signals of the cables, springs, hinges, wheels, supports and other mechanical assembly parts.
  • Do not use the product if it is necessary repair or adjustment is required.
  • When performing maintenance, cleaning and replacement of parts, the product must be disconnected from power supply. Also including any operation that requires opening the product cover.
  • The use, cleaning and maintenance of this product may be carried out by any persons aged eight years old and over and persons whose physical, sensorial or mental capacities are lower, or by persons without any knowledge of the product, provided that these are supervision and instructions given by persons with experienced in terms of usage of the product in a safe manner and who understands the risks and dangers involved.
  • Children shouldn’t play with the product or opening devices to avoid the motorized door or gate from being triggered involuntarily.

WARNINGS FOR TECHNICIANS

  • Before beginning the installation procedures, make sure that you have all the devices and materials necessary to complete the installation of the product.
  • You should note your Protection Index (IP) and operating temperature to ensure that is suitable for the installation site.
  • Provide the manual of the product to the user and let them know how to handle it in an emergency.
  • If the automatism is installed on a gate with a pedestrian door, a door locking mechanism must be installed while the gate is in motion.
  • Do not install the product “upside down” or supported by elements do not support its weight. If necessary, add brackets at strategic points to ensure the safety of the automatism.
  • Do not install the product in explosive site.
  • Safety devices must protect the possible crushing, cutting, transport and danger areas of the motorized door or gate.
  • Verify that the elements to be automated (gates, door, windows, blinds, etc.) are in perfect function, aligned and level. Also verify if the necessary mechanical stops are in the appropriate places.
  • The central must be installed on a safe place of any fluid (rain, moisture, etc.), dust and pests.
  • You must route the various electrical cables through protective tubes, to protect them against mechanical exertions, essentially on the power supply cable. Please note that all the cables must enter the central from the bottom.
  • If the automatism is to be installed at a height of more than 2,5m from the ground or other level of access, the minimum safety and health requirements for the use of work equipment workers at the work of Directive 2009/104/CE of European Parliament and of the Council of 16 September 2009.
  • Attach the permanent label for the manual release as close as possible to the release mechanism.
  • Disconnect means, such as a switch or circuit breaker on the electrical panel, must be provided on the product’s fixed power supply leads in accordance with the installation rules.
  • If the product to be installed requires power supply of 230Vac or 110Vac, ensure that connection is to an electrical panel with ground connection.
  • The product is only powered by low voltage safety with central (only at 24V motors)

WARNINGS FOR USERS

  • Keep this manual in a safe place to be consulted whenever necessary.
  • If the product has contact with fluids without being prepared, it must immediately disconnect from the power supply to avoid short circuits, and consult a specialized technician.
  • Ensure that technician has provided you the product manual and informed you how to handle the product in an emergency.
  • If the system requires any repair or modification, unlock the automatism, turn off the power and do not use it until all safety conditions have been met.
  • In the event of tripping of circuits breakers of fuse failure, locate the malfunction and solve it before resetting the circuit breaker or replacing the fuse. If the malfunction is not repairable by consult this manual, contact a technician.
  • Keep the operation area of the motorized gate free while the gate in in motion, and do not create strength to the gate movement.
  • Do not perform any operation on mechanical elements or hinges if the product is in motion.

RESPONSABILITY

  • Supplier disclaims any liability if:
    • Product failure or deformation result from improper installation use or maintenance!
    • Safety norms are not followed in the installation, use and maintenance of the product.
    • Instructions in this manual are not followed.
    • Damaged is caused by unauthorized modifications
    • In these cases, the warranty is voided.
MOTORLINE ELECTROCELOS SA.

Travessa do Sobreiro, nº29
4755-474 Rio Côvo (Santa Eugénia)
Barcelos, Portugal

SYMBOLS LEGEND:

Symbol| Important safety notices
---|---
Symbol| Useful information
Symbol| Programming information
Symbol| Potentiometer information
Symbol| Connectors information
Symbol| Buttons information

DEVICE

DESCRIPTION

MLS4 is a waterproof standalone access control, reading EM&HID card. It uses an advanced Microprocessor, with high-capacity flash memory for 10000 users. Users can be easily added and deleted via admin card. The infrared remote control allows the device not only to have alarm, protection, anti-pass back function but also allows to install two units interlocked and add and delete the user on the device. Besides, it has a low power consumption, anti- theft alarm and door release button. All these characteristics make it convenient, safe and reliable.

FEATURES
Feature Description
Waterproof Design Rainproof, moistureproof , durable
Ultralow power consumption Longer working life, more stable performance
Large capacity 10 000 user cards
Wiegand reader Can be used as wiegand 26 output reader
External reader connection Can be connected an EM/IC/HIDwiegand 26 output

reader
Two devices interlocked| Two devices can be interlocked online
Anti-passback| Single door or two doors anti-passback

TECHNICAL CHARACTERISTICS
•  Power Supply 12Vdc ± 10%
•  Static current <30mA
•  Card maximum reading distance 5 ~ 8cm
•  Operating temperature -25°C ~ 55°C
•  Operating humidity 20% ~ 98%
•  Output load blocking 2A
•  Alarm Output load 2A
•  Management card 2 units

INSTALLATION AND CONNECTIONS

DEVICE INSTALLATION
  1. Drill the holes according to the distance and the dimension on the back cover, or install the distributing box;
  2. Pass the cable through the hole, connect the necessary wires and insulate the unused wires with insulation tape to safeguard a short circuit;
  3. Fix the back cover on the wall with special screws;
  4. Fix the front cover to the back cover with the screws.
WIRES
Line sequence Marks Color Description
1 D0 Green WG output line D0
2 D1 White WG output line D1
3 OPEN Yellow Exit button
4 +12V Red +12V Input
5 GND Black GND
6 NO Blue Relay NO end
7 COM Purple Relay Com
8 NC Orange Relay NC end

Symbol Note • Please check all wires and install the front cover carefully before turn on the device.

INSTALLATION AND CONNECTIONS

STANDALONE FOR A DOOR WITH POWER SUPPLY
  • ELECTRIC LOCK
    Electric Lock
STANDALONE FOR A DOOR WITH POWER SUPPLY
  • ELECTROMAGNETIC LOCK
    Electromagnetic Lock

WIEGAND READER CONNECTION

Wiegand Reader Connection

CONFIGURATION

FACTORY RESET AND SET MANAGEMENT CARD

Connect the yellow wire to the black wire and turn on the power. After the sound “didi”, Factory reset is finished. When indication LED turns green, it means you can set the two admin cards. Read the first card as admin add card. After that read the second card as admin delete card. Then LED turns red flash, and after that, the device can work normally.
Note • Reset factory default won’t delete user cards. If you present the same card on the second read,
the device will whistle 3 consecutive times indicating error. Then you can continue present another card. If doesn’t happen operations within 10seconds, the device will enter working mode automatically and the parameter will reset to factory default.

ADMIN SETTING ON KEYPAD

Entering admin operating mode| Press  * master code   # factory default: 999999

Note • All the below operations need to be under programming mode.

---|---
Change the master code| Press 0 new code # repeat new code #

Note • Master Code length: 6~8 digits

Add users via remote control:

Read card to add user Press 1 read card # read card #
Use ID Number to add user Press  1 card number # card number #

Note • 1 Card number must be 8 or 10 digits. If the card number has less than 8 or 10 digits, type 0 before the card number 2 press # confirm, press last # finish, press ***** exit.

Add consecutive number card| Press 1 cards quantity # 8 or 10 digits card number

Add consecutive user card numbers, card quantity 1 9999, green fast flash

PRODUCT INSTALLATION

Delete users via remote control:

Read card to delete user Press 2  read card read card ... #
Use card NO. to delete user Press 2 8 or 10 digits card number # `8 or 10

digits card number   # ...`#
Delete all users| Press 2000 #

Note • This operation will delete all users, but admin cards won’t be deleted.

Safe mode setting:

Normal mode (factory default) Press 3 0 #
Dead mode Press 3 1 #

Read invalid cards 10 times continuously within 10 minutes it will take the device to a dead status for 10 minutes.

Set Door impulse time| Press 4 0~99  #
Range “0~99 seconds”, 0mS equates 50mS.

Set Red light mode:

Static off mode Press 6 0 #
Static on mode (factory default) Press 6 1 #

Set Interlock:

Close interlock
(factory default)| Press 7 0 #
---|---
Open interlock| Press 7 1 #

Set Anti-passback:

Disable anti-passback
(factory default)| Press 8 0 #
---|---
Enable hosting antipassback mode| Press 8 1 #
Enable anti-passback
subsidiary mode| Press 8 1 #
Note • Details will be illustrated in Advanced Application below.

ADMIN CARD OPERATION

Add user:

Press: read admin add card read user card 1 read user card 2 … , finally read admin add card exit.

Delete user:

Press:  read admin add card read user card 1 read user card 2 … , finally read admin deleted card card exit.

OPEN DOOR AS USER

Read user card| Read a valid user card. Door will be open, but admin card can’t open the door.
---|---

SOUND AND LIGHT INDICATION
OPERATION LED COLOR BUZZER
Initialization Orange Bip Bip
Static Red Flash
Valid key   Long bip
Enter programme Red Long bip
Setting Orange Bip
Exit Red Flash Long bip
Operation Failed   Bip Bip
Lock open Green Long bip
Add sequential No. card Green Quick Flash
ADVANCED CONFIGURATIONS
  1. Two devices for single door
    Install one device at indoor and the other at outdoor. Indoor device it’s the controller and the outdoor device works as reader. The difference between two interlocked devices for a single door and standalone for single is below:

  2.  Add users on both devices. Both indoor user data and outdoor data can be shared. Users can be added up to 10 000.

  3. The setting of the two device must be the same. When admin PIN setting is different, outdoor device can’t open the door with saved users data.

  4. Two devices interlocked for two doors
    Install two controllers for two doors in way to control two locks separately, set interlocked for two devices, open door contact. One door is locked when the other door is open. The device can’t control another electric lock and saved data can’t be shared between different devices. This function mainly apply for bank, prison etc.

  5. Anti-passback for Single door
    Install a common reader outdoor (or use this device without any card No. for reader). Install this device outdoor and set it as anti-passback host mode. In this case, the two devices consist of an anti-passback system for single door, mainly apply to controlling enter and exit for single door. Functions as follows:

  6. Set the necessary functions and add an user card on the host device.

  7. Users can only present the card on the external reader to enter, and then present the card on the
    host device to exit. Users can’t enter or exit 2 consecutive times.

  8. Anti-passback for two doors
    Install one device on Door 1 in auxiliary anti-passback mode. Install one device on Door 2 in hosting antipassback mode. In this case, the two devices consist in a anti-passback for two doors, mainly apply for one-way in and out for double doors like a parking. Functions as follows:

  9. Set the necessary functions and add an user card on the host device.

  10. Users can only present the card on the auxiliary device to enter, and then present the card on the hosting device to exit. Users can’t enter or exit at 2 consecutive times.