HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual

June 9, 2024
HILTI

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual

HILTI X-CC U CEILING CLIP with Nail Submission Folder User
Manual

Ceiling hanger X-CC
APPLICATIONS Ceiling suspensions on concrete and steel

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
APPLICATIONS

Product data

DimensionsHILTI X-CC U CEILING CLIP with Nail Submission Folder User
Manual - Dimensions

Material specifications

Carbon steel shank: HRC 58 X-HS M _ DKH, X-HS M/W_U, X-CC_U
HRC 56 X-CC_CS
X-HS: Zinc coating: 10 μm
X-CC U: Zinc coating: 2.5 μm
X-CC CS : Zinc coating: ≥ 5 μm
X-U / DKH Nail: Zinc coating: 5–20 μm
X-CS Nail: Zinc coating: 5–20 μm

Recommended fastening tools DX 6 F8, DX 5 F8, DX 460-F8, DX 351-F8, DX 36, DX 2, DX E72
· See system recommendation in the next pages.

Technical Information

Approvals and certificates

Lloyds Register: ICC, UL, FM:

X-HS X-HS W6/10

Not all information presented in this product data sheet might be subject to approval / certificate content. Please refer to approval/certificate for further information.

Applications

Examples

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Threaded
rod attachments to concrete and steel

Performance data
Recommended resistance under tension and shear load
Concrete (DX-Kwik with pre-drilling) or stee

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Recommended resistance under tension and shear load HILTI
X-CC U CEILING CLIP with Nail Submission Folder User Manual - Recommended
resistance under tension and shear load

Application recommendation

Base material thickness

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Base
material thickness

Fastener positioning
Minimum spacing and edge distances: See corresponding nail data sheet of X-U and X-DKH.

Application limits

Fastening to steel ­ X-HS U19 with DX351

Application limit may increase in case of specific applications, like the fastening of wire mesh to steel, which is connected with X-CC U16 P8 fasteners. That wire mesh acts as reinforcement for fire protective sprayed coating. In such cases also different fastener stand-offs apply. Inquire at Hilti related with the use of X-CC U16 P8 in that specific application.

Corrosion information

  • These zinc-coated fasteners are not suitable for long-term service outdoors or in otherwise corrosive environments.
  • For more details, please refer to following technical document: Hilti Corrosion Handbook.

System recommendation

  • For more details, please refer to the chapter Accessories and consumables compatibility in the Direct Fastening Technology Manual (DFTM).

Technical information

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Technical information

Cartridge recommendation for fastening on concrete

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Cartridge recommendation for fastening on concrete

Cartridge recommendation for fastening on steel

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Cartridge recommendation for fastening on steel

  • Tool power level adjustment by setting tests on site.
  • Start tool energy selection with lowest recommended tool power level.
  • Correct according requirement from chapter quality assurance.

Quality assurance
Installation

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Installation

Setting depth control

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Setting
depth control

These are abbreviated instructions which may vary by application.
ALWAYS review/follow the instructions accompanying the product.

Fastener program
Item no. and description

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Fastener
program

Setting Instructions

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - How to
use

Material Safety Dara Sheet

SECTION 1: Identification
1.1. GHS Product identifier

Product form Article
Trade name DX-Cartridge
UN-No. (ADR) 0323
Product code BU Direct Fastening

1.2. Other means of identification

No additional information available

1.3. Recommended use of the chemical and restrictions on use

Use of the substance/mixture CARTRIDGES FOR TOOLS, BLANK
Recommended uses and restrictions For professional use only

1.4. Supplier’s details

Supplier
Hilti (Hong Kong) Ltd.
701-704, 7/F, Tower A, Manulife Financial Centre
223 Wai Yip Street, Kwun Tong
Kowloon – Hong Kong
T +852 27734 700
Department issuing data specification sheet
Hilti Entwicklungsgesellschaft mbH
Hiltistraße 6
86916 Kaufering – Deutschland
T +49 8191 906876

1.5. Emergency phone number

Emergency number

Schweizerisches Toxikologisches Informationszentrum ­ 24h Service +41 44 251 51 51 (international) +852 27734 700

SECTION 2: Hazard identification

The dismantling of the article is prohibited!,This article contains hazardous substances or preparations not intended to be released under normal or reasonably foreseeable conditions of use.

2.1. Classification of the substance or mixture

Classification according to the United Nations GHS Explosives, Division 1.4
Full text of H-statements: see section 16
H204
Expert judgment

2.2. GHS Label elements, including precautionary statements

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - GHS
Label elements, including precautionary statements

Precautionary statements (GHS UN)

P210 – Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P250 – Do not subject to shock, friction, grinding. P280 – Wear eye protection. P372 – Explosion risk. P370+P380+P375 – In case of fire: Evacuate area. Fight fire remotely due to the risk of explosion. P401 – Store in accordance with local regulations on explosives.

2.3. Other hazards which do not result in classification

Other hazards not contributing to the classification

This article contains hazardous substances or preparations not intended to be released under normal or reasonably foreseeable conditions of use., The dismantling of the article is prohibited!, Keep away from ignition sources (including static discharges)

SECTION 3: Composition/information on ingredients

3.1. Substances Not applicable

3.2. Mixtures

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Mixtures HILTI
X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Mixtures

SECTION 4: First-aid measures

4.1. Description of necessary first-aid measures

First-aid measures general

In all cases of doubt, or when symptoms persist, seek medical attention.

First-aid measures after inhalation

Allow affected person to breathe fresh air. Allow the victim to rest.

First-aid measures after skin contact

Remove affected clothing and wash all exposed skin area with mild soap and water, followed by warm water rinse.

First-aid measures after eye contact

Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness persists.

First-aid measures after ingestion

Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.

4.2. Most important symptoms/effects, acute and delayed

Symptoms/effects

Not expected to present a significant hazard under anticipated conditions of normal use.

Potential adverse human health effects and symptoms

No additional information available. No harmful effects are to be expected if used properly. The contained ingredients can be harmful, but they are hermetically enclosed in the article and can not be released. The dismantling of the article is prohibited.

4.3. Indication of immediate medical attention and special treatment needed, if necessary No additional information available

SECTION 5: Fire-fighting measures

5.1. Suitable extinguishing media Suitable extinguishing media Unsuitable extinguishing media

Dry powder. Water spray. Do not use a heavy water stream.

5.2. Specific hazards arising from the chemical

Hazardous decomposition products in case of fire

Carbon monoxide. Carbon dioxide (CO2). Nitrous gasses.

X-CC U Ceiling Clip with Nail

5.3. Special protective actions for fire-fighters

Firefighting instructions

Use water spray or fog for cooling exposed containers. Exercise caution when fighting any chemical fire. Prevent fire fighting water from entering the environment.

Protection during firefighting

Do not enter fire area without proper protective equipment, including respiratory protection.

SECTION 6: Accidental release measures

6.1. Personal precautions, protective equipment and emergency procedures

General measures

Remove ignition sources. Use special care to avoid static electric charges. No open flames. No smoking.

6.1.1. For non-emergency personnel Emergency procedures

Evacuate unnecessary personnel.

6.1.2. For emergency responders Protective equipment Emergency procedures

Equip cleanup crew with proper protection. Ventilate area.

6.2. Environmental precautions Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters.

6.3. Methods and materials for containment and cleaning up

Methods for cleaning up

Pick up loose cartridges only by hand. Exposed ingredients must be swept up carefully and phlegmatized in a water container, labelled according the regulations, wipe down with water the contamined area. Store away from other materials.

SECTION 7: Handling and storage

7.1. Precautions for safe handling Precautions for safe handling
Hygiene measures Additional hazards when processed

Do not subject to grinding,shock, friction. Take precautionary measures against static discharge. Wash hands and other exposed areas with mild soap and water before eating, drinking or smoking and when leaving work.
Do not eat, drink or smoke when using this product. Always wash hands after handling the product.
Hazardous waste due to potential risk of explosion.

7.2. Conditions for safe storage, including any incompatibilities

Storage conditions

Keep only in the original container in a cool, well ventilated place away from : Direct sunlight, Heat sources. Store in a dry place.

Storage area

Store away from heat.

Incompatible products

Strong bases. Strong acids.

Information on mixed storage

Keep away from : Ignition sources. Do not store with: Store according to local legislation.

Storage temperature

5 ­ 25 °C

SECTION 8: Exposure controls/personal protection

8.1. Control parameters No additional information available

8.2. Appropriate engineering controls Other information

Do not eat, drink or smoke during use.

8.3. Individual protection measures, such as personal protective equipment (PPE)

Eye protection

Safety glasses

Skin and body protection

When using cartridge operated tools, sufficient ear protection must be worn.

Personal protective equipment symbol(s)

8.4. Exposure limit values for the other components No additional information available

SECTION 9: Physical and chemical properties

9.1. Basic physical and chemical properties

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Basic
physical and chemical properties

9.2. Data relevant with regard to physical hazard classes (supplemental)

Additional information

Not applicable

Article

SECTION 10: Stability and reactivity
10.1. Reactivity No additional information available
10.2. Chemical stability Stable under normal conditions.
10.3. Possibility of hazardous reactions Not established.
10.4. Conditions to avoid Direct sunlight. Extremely high or low temperatures. Heat. Sparks. Open flame. Overheating.
10.5. Incompatible materials Strong acids. Strong bases.
10.6. Hazardous decomposition products Carbon monoxide. Carbon dioxide. Nitrogen oxides. Metal oxides. Thermal decomposition can lead to the release of irritating gases and vapours.

SECTION 11: Toxicological information

11.1. Information on toxicological effects

Acute toxicity (oral) Not classified
Acute toxicity (dermal) Not classified
Acute toxicity (inhalation) Not classified

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Information on toxicological effects HILTI X-CC U CEILING
CLIP with Nail Submission Folder User Manual - Information on toxicological
effects

SECTION 12: Ecological information

12.1. Toxicity

Ecology – general No harmful effects are to be expected if used properly.
The contained ingredients can be harmful, but they are hermetically enclosed in the article
and can not be released.
The dismantling of the article is prohibited.
Hazardous to the aquatic environment, shortterm (acute)
Not classified
Hazardous to the aquatic environment, long-term
(chronic)
Not classified

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Toxicity HILTI
X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Toxicity HILTI
X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Toxicity

12.3. Bioaccumulative potential

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Bioaccumulative potential

12.4. Mobility in soil

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Mobility
in soil HILTI
X-CC U CEILING CLIP with Nail Submission Folder User Manual - Mobility in
soil

12.5. Other adverse effects

Ozone Not classified
Other adverse effects No additional information available
Other information Avoid release to the environment.

SECTION 13: Disposal considerations

13.1. Disposal methods Product/Packaging disposal recommendations
Ecology – waste materials Additional information
Dispose in a safe manner in accordance with local/national regulations. Refer to manufacturer/supplier for information on recovery/recycling.
Avoid release to the environment.
Cartridge strips with unused cartridges: Hazardous waste due to risk of explosion. European waste catalogue: 16 04 01* – waste ammunition. If possible use up the cartridges or store them for your next project. If not possible to use up the cartridges – The strip is mixed municipal waste and the cartridge itself is “waste ammunition” and has to be disposed of by an authorized/certified company. If cartridges are used up: European waste catalogue: 20 03 01 – mixed municipal waste . The product (cartridges and strip) can be disposed of as household or factory waste.

SECTION 14: Transport information
In accordance with ADR / IMDG / IATA / RID

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual -
Transport information HILTI X-CC U CEILING CLIP with Nail
Submission Folder User Manual - Transport information

14.6. Special precautions for user

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Special
precautions for user

14.7. Maritime transport in bulk according to IMO instruments
Not applicable

SECTION 15: Regulatory information
15.1. Safety, health and environmental regulations specific for the product in question No additional information available

SECTION 16: Other information

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Other
information HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Other
information HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Other
information HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Other
information

SDS_UN_Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product.

Letters Country of Origin

Attn. : To whom it may concern
Date : 28 June 2022
Ref. : 050/FP/RY/22
Subject : Country of Origin- Hilti Ceiling clip X-CC
Dear Sir / Madam,
Enclosed please find the information of Hilti Ceiling clip X-CC
Brand Name : Hilti
Model Name : Hilti Ceiling clip X-CC
Manufacturer : Hilti Corporation
Address of Manufacturer : FL-9494, Principality of Liechtenstein.
Manufacturer Contact Person : Ricky Yau
Supplier : Hilti (Hong Kong) Ltd
Address of Supplier : 701-704, 7/F, Tower A, Manulife Financial Centre,
223 Wai Yip Street, Kwun Tong, Kowloon, Hong Kong
Supplier Contact Person : Ricky Yau (+852 9317 6203)
Country of Origin : Austria

Should you have further questions, please do not hesitate to contact our Technical Representatives, Customer Service Hotline at 8228-8118, or email us at hksales@hilti.com.

Yours faithfully,

Ricky Yau Head of Product Leadership Strategy Hilti (Hong Kong) Ltd.

Job Reference

Hilti X-CC U Ceiling Clip with Nail Job Reference

HILTI X-CC U CEILING CLIP with Nail Submission Folder User Manual - Hilti
X-CC U Ceiling Clip with Nail Job Reference

Documents / Resources

| HILTI X-CC U CEILING CLIP with Nail Submission Folder [pdf] User Manual
X-CC U CEILING CLIP with Nail Submission Folder, X-CC U, CEILING CLIP with Nail Submission Folder, CLIP with Nail Submission Folder, Nail Submission Folder, Submission Folder
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals