Schneider Electric IMT47216 Mureva Lights User Manual

June 9, 2024
Schneider Electric

Schneider Electric logo Mureva Lights
User Manual

IMT47216 Mureva Lights

IMT47216
IMT47217| | Model :IMT47216/IMT47217
Material : Aluminum+Glass
Watt : 20W
Voltage : 220-240V~50Hz
Input current: 0.100A
Lumen: 2000LM
CCT: 4000K/6500K
Size : 186x167x58mm
Net Weight : 570g
Beam Angle : 110°
PF : 0.85
Lighting area :0.021m²| Schneider Electric IMT47216 Mureva Lights - fig
4
---|---|---|---
IMT47218
IMT47219| | Model :IMT47218/IMT47219
Material : Aluminum+Glass
Watt : 30W
Voltage : 220-240V~50Hz
Input current: 0.141A
Lumen: 3000LM
CCT: 4000K/6500K
Size : 204x193x58mm
Net Weight : 820g
Beam Angle : 110°
PF : 0.9
Lighting area :0.028m²| Schneider Electric IMT47216 Mureva Lights - fig
5
IMT47220
IMT47221| | Model :IMT47220/IMT47221
Material : Aluminum+Glass
Watt : 50W
Voltage : 220-240V~50Hz
Input current: 0.225A
Lumen: 5000LM
CCT: 4000K/6500K
Size : 224x219x58mm
Net Weight : 1100g
Beam Angle : 110°
PF : 0.9
Lighting area :0.036m²| Schneider Electric IMT47216 Mureva Lights - fig
6

Welcome to use KPR22-M9 Infrared motion sensor!
The product is a new saving-energy switch, it adopts good sensitivity detector, integrated circuit. It gathers automatism, convenient safe, saving- energy and practical functions. It utilizes the infrared energy from human as control-signal source, it can start the load at once when one enters detection field. It can identify day and night automatically. It is easy to install and used widely.Schneider Electric IMT47216 Mureva Lights - fig
7

SPECIFICATION:

Power Source: 220 -240V/AC Detection Range: 120°
Power Frequency: 50Hz Working Temperature: -30~+50℃
Ambient Light: 5-2000LUX (adjustable) Working Humidity: <93%RH

Time-Delay: min: 3 sec±3sec
max: 8min±3sec| Installation Height: 1.8m~2.5m
Detection Distance: 4~10m (<24℃)
Rated Load: 100W (led lamp)

FUNCTION :

  • Can identify day and night: The consumer can adjust work ambient light. It can work in the daytime and at night when it is adjusted on the “sun” position (max). It can work in the ambient light less than 3LUX when it is adjusted on the “moon” position (min). As for the adjustment pattern, please refer to the testing pattern.
  • SENS adjustable: It can be adjusted according to using location, Maximum 10m, it fits for large room.
  • Time-delay is added continually: When it receives the second induction signals after the first induction, it will compute time once more on the rest of the first time-delay basic (set time).
  • Time-delay adjustment: It can be set according to the consumer’s desire. The minimum time is 10sec±3sec. The maximum is 7min±3min.

TEST :

  • Turn the SENS knob clockwise on the maximum, turn the TIME knob anti-clockwise on the minimum, turn the LUX knob clockwise on the maximum(SUN).
    Schneider Electric IMT47216 Mureva Lights - fig 8

  • When you switch on the power, the controlled load is not working. Preheat 30 seconds later, when the sensor gets the induction signal, the load will be turned on. After the load is turned off, it will be turned on again when the sensor gets induction signal within 5~15 sec.

  • After the first is out, make it sense again after 5~10sec. The load should work. When there is no induction signals in the sensor, the load should be stopped working.

  • Turn LUX knob anti-clockwise on the minimum. If it is adjusted in the less than 3LUX(dark), the load and sensor should not work when testing in daylight. If you cover the detection window with the opaque objects (towel etc), the load work. Under no induction signal condition, the load should stop working within 5-15sec.

Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work!
NOTE :

  • Should be installed by electrician or experienced person.
  • Avoid installing it on the unrest object.
  • There should be no hindrance and moving objects in front of the detection windows to effect detection.
  • Avoid installing it near air temperature alteration zones such as air condition, central heating, etc.
  • Considering your safety, please do not open the cover when you find the hitch after installation.
  • If there is difference between instruction and the function the product has, please give priority to product and sorry not to inform you additionally.

SOME PROBLEM AND SOLVED WAY :

  • The load do not work:
    a. please check if the connection-wiring of power and load is correct.
    b. please check if the load is good.
    c. please check if the working light set correspond to ambient light.

  • The sensitivity is poor:
    a. Please check if there has hinder in front of the detection window to effect to receive the signal.
    b. Please check if the ambient temperature is too high.
    c. Please check if the induction signal source is in the detection fields.
    d. Please check if the installation height corresponds to the height showed in the instruction.
    e. Please check if the moving orientation is correct.

  • The sensor can not shut off the load automatically:
    a. Please check if there is continual signal in the detection field.
    b. Please check if the time delay is the longest.
    c. Please check if the power corresponds to the instruction.
    d. Please check if the temperature near the sensor changes obviously, such as air condition or central heating etc.

Impotent User Advice

This Product is Class I and must be Earthed. Always switch off mains supply before fitting. Replace any broken or damaged glass as soon as possible. Ensure all seals are intact and operational after fitting or maintenance. Do not touch the lamp in use or just after use as there is a risk of being burnt. Do not cover it with paper or cloth. Take off from flammable materials. Do not wash the lamp. Do not use the lamp where the ambient temperature is over 45°C. Keeping your eyes with a security distance,the light could cause damage. This product has no user serviceable parts. Clean with a damp cloth and dry with a lint free cloth or kitchen towel. The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced

Installation

Only to be installed outside arms reach. prepare the mains wiring. Use the mounting bracket to mark the hole centres for fixing. Drill holes suitable to accept wall plugs.Insert wall plugs. Ensure mounting bracket. Terminate wiring.Pay particular attention to any markings for Repalce all covers. Fit the floodlight to the mounting bracket with the screws, Check seals,gaskets and cable gland operation before testing the luminaire. Turn on power supply and test luminaire. The installation height should be from 2.25 to 5 meter.

Important Infomation

It is recommend that luminaires installed and fitted by a qualified electrican ensuring the installation complies to the current building regulations.These products are designed for connection to a 230VAC 50Hz supply. Any broken or damaged parts should be replaced as soon as possible. Schneider will not accept responsibility for any claims arising from a poor installation.
Wire connection guide
The brown wire is connected with the L wire of city electricity. The blue one is connected with the N wire of city electricity. The green/yellow one is connected with the earth wire. Power Cord type HOSRN-F 3 x 1.0mm2, cable length 50cm Terminal block is not included. The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed.

Schneider Electric IMT47216 Mureva Lights - fig 9 Diagram Showing

Schneider Electric IMT47216 Mureva Lights - fig 10

Schneider Electric IMT47216 Mureva Lights - icon 1 Patented Product, Counterfeiting Not Allowed.
SCHNEIDER ELECTRIC INDUSTRIES SAS
35, RUE JOSEPH MONIER
92500 RUEIL-MALMAISON – FRANCE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals