SAFTEY INSTRUCTION
WARNING
(To reduce the risk of fire, electric shock, or personal injury):
- We suggest installation by a licensed electrician.
- Please read the instruction carefully and save it as you may need it at a later time.
- Before you start, NEVER attempt any work without shutting off the electricity until the work is done
- Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
- Place the wall switch in the “OFF” position.
- Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
- Make sure that the ceiling or wall can stand the weight of the lamp before installation.
- Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
- Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
- When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
- The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT
TOOLS REQUIRED (NOT INCLUDED)
Before starting assembly and installation please prepare the needed tools as below picture
-
Ladder
-
Phillips head flat blade screwdriver
-
Electrical Tape
-
Pliers
-
Wire cutter/Stripper
PARTS TYPE & QTY INCLUDING:
- (C) Single bar (1)
- (D) Green ground screw (1)
- (E) Canopy (1)
- (F) Loop (4)
- (G) Hex nut (1)
- (H) Cap nut (1)
- (I) Quick link (2)
- (J) Tube
- (K) Shorter screw (4)
- (L) Flat iron stent (2)
- (M) Stem (2)
- (N) Upper frame (2)
- (O) Lower frame (2)
- (P) Longer screw (16)
- (Q) Sockets assembly (2)
- (R) Shorter pipe (48)
- (S) Longer pipe (72)
ACCESSORIES & QTY ENCLOSED:
- (A) Wire connector (3)
- (B) Mounting screw (2)
ASSEMBLY & INSTALLATION INSTRUCTIONS
- . Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
- Make pre installation
Step A1
crew stems (M) and flat iron stents (L) together, then screw them onto
sockets assemblies (Q). By group, screw longer pipes (S) and shorter
pipes (R) onto the same circle as shown above.
Step A2
Insert lower frames (O) into flat iron stents (L), and secure them
with shorter screws (K).
Step A3
Thread longer screws (P) into lower frame (O) and then into upper frame (N).
Tighten till snug.
StepB1
According to your desired fixture height, use and screw the chosen tubes
(J) onto the top of flat iron stents (L).
Step B2
Attach quick links (I) to loops (F) on canopy (E) and tubes
(J). Carefully pass wires through loops (F) and canopy (E). Gently
pull the wires to ensure the wires are not stressed.
Turn off power
Before you start the installation, NEVER attempt any work without shutting off
the electricity until the work is done
- Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position.
- Place the wall switch in the “OFF” position.
Make installation
StepC1
Unscrew hex nut (G) and cap nut (H) from single bar (C).
StepC2
Attach single bar (C) to the outlet box with mounting screws (B).
Note:
the side of single bar (C) marked “GND” must face out.
Step C3
If needed, shorten the length of fixture wires. At this point, the remaining
wire length measured above single bar (C) is at least 6″.
Step C4
Make wire connections
Connect wires as below wires connection shown. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect black or red supply wire to: | Connect white supply wire to: |
---|---|
Black | White |
Parallel cord (round & smooth) | Parallel cord (square & ridged) |
Clear , brown gold or black without tracer | Clear brown gold or black with |
tracer
Insulated wire (other than green ) with copper conductor| Insulated wire
(other than green ) with silver conductor
Note
when parallel wires(SPTI & SPT II) are used.The neutral wire is square
shaped or ridged and the other wire will be round in shape or smooth (see
illus).
Twist wires together with plastic wire connectors until tightly joined, and wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
Step C5
Raise canopy (E) to the ceiling and secure canopy (E) in place by
tightening hex nut (G) and cap nut (H) onto the preassembled threaded
nipple on single bar (C).
NOTE:
The canopy (E) should be snug against the ceiling and cap nut (H). If
not, adjust the threaded length of the preassembled threaded nipple on single
bar (C) by:
- First, unscrew the preassembled hex nut;
- Then, screw the preassembled threaded nipple in or out of single bar (C);
- When the secure length is achieved, tighten the preassembled hex nutand back to step C5.
Step C6
Install bulbs (not included) (Please do not exceed the maximum wattage
recommended on the socket.)
Check everything is already installed properly, then you could turn on the light. Enjoy!
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement
parts. All parts for this fixture can be ordered from the place of purchase.
Be sure to use exact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Do not use abrasive materials
such as scouring pads or powders, steel wool or abrasive paper.