HUMAN CARE neXus 3 Rollator Walker Instruction Manual
- June 9, 2024
- HUMAN CARE
Table of Contents
neXus 3 Rollator Walker
Instruction Manual neXus 3
Reconditioning Manual
Maintenance, inspection and testing
To ensure that your walking aid is functioning properly and safely, an annual
inspection should be done only by an authorized agent.
The following maintenance should be done regularly:
Cleaning
Regular cleaning with a mild liquid detergent or wiping with a damp cloth is
recommended. DO NOT use any toxic cleaning materials, chlorine bleach or
abrasive cleansers on the product as it will damage it. DO NOT pressure wash.
Post treatment
Lubricate any moving parts. Ensure the rollator is free of residue moisture to
avoid rusting its components. DO NOT keep near a heat source.
Chassis
Check the weldings for any visible signs of damage. Should damage be evident,
cease usage and immediately have the rollator inspected. Replace if necessary.
Finish
The rollator is painted and sealed for a superior finish, however scratches
can occur with impact. Scratches in the frame may result in corrosion.
Corrosive components
The rollator does contain components that may rust if left in a moisture
setting. Periodically check all welding points and screws. It is recommended
that an authorized agent perform this inspection. If corrosion is present,
replace parts. If corrosion is extensive, replace rollator.
Periodic inspections
At minimum, it is recommended that an authorized agent perform an annual
inspection of the rollator and its components to ensure it is functioning as
intended. Do not use the rollator if any components are damaged or inoperable.
Have an authorized agent perform necessary repair and/or replacement.
Handle grip
Periodic replacement of the handle grip may be necessary with usage. Replace
as required.
Braking system
The brakes should function in both the control and park position. The handle
should stay in the “locked” position when pushed down and easily move up when
“squeezed” towards the grip. Should these control functions not operate as
intended, cease usage and immediately have the rollator repaired.
Height adjustment
Control function. Check star handle to ensure it is securely fastened.
CE-marking
Ensure that the CE-marking is present and legible.
Folding mechanism
Control function
Wheels
Ensure the wheels are not worn out and spin easily to ensure proper movement
of the rollator. If any noise is heard, have an authorized agent inspect
product.
Seat
Periodically check to ensure that the seat mechanism and screws are firmly in
place. If any components are not secure, do not sit on the rollator and have
it inspected for repair immediately. If used, ensure the seat pad is properly
mounted in the seat place for maximum comfort.
Stability
The wheels should all rest firmly on the ground and that there should be no
distortion of the frame.
Walking Test
Before using your rollator, take a small walk with it to ensure it is properly
functioning.
Authorized Dealer/Service Agent………………………..
Last Service Date……………………….
Warnings and Recommendations
Intended use
This rollator was designed to act as a support device while walking or as a
resting seat while stationary and locked into position. It should never be
used as a transport device. Never attempt to alter the rollator in any way.
Note!
Reconditioning must be done only by an authorized agent. If incorrectly
performed by an unauthorized individual, it could result in an
accident/injury.
To locate an authorized agent, contact your local office:
Europe: info.se@humancaregroup.com
Canada: info.ca@humancaregroup.com
United States: info.us@humancaregroup.com
Australia: info.au@humancaregroup.com
Netherlands: info.nl@humancaregroup.com
When exchanging parts on the rollator, use only Human Care authorized parts to
ensure continued CE-validation.
If corrosion is more than a film of rust, discard and recycle rollator
according to local regulations.
Never use this rollator in any way other than for its intended purpose.
It is strongly recommended that a therapist or doctor assess your needs prior
to using this product.
Inspect your rollator frequently prior to usage to ensure there is no damage
or wear.
User must not exceed this product’s weight capacity!
NeXus 3
200kg/441lb
Note: Reconditioning guidelines may vary from country to country. Ensure
that any reconditioning performed follows local regulations.
Exploded View
Spare Parts
No | Designation (Qty/Rollator) | UofM | Art. no | Additional Instructions |
---|---|---|---|---|
1 | Brake Handle Complete (1 required/ea) | Standard with rollator | ||
Right – Red Ball | 93243 | |||
Left- Red Ball | 93201 | |||
Brake Handle Complete Short (1 required) | Optional | |||
Right – Red Ball | 93245 | |||
Left- Red Ball | 93244 | |||
2 | Star Handle and Bolt (2 required) | g | 89096 | For models after 2009 |
Star Handle (Wing Nut) | ||||
Bolt | ||||
3 | Bolt Cap | EA | 4823 | |
4 | Front Fork Stem Nut | EA | H48025 | |
5 | Rear Fork Tubing Nut | EA | H48031 | |
6 | Rear Fork Tubing Screw | EA | H48030 | |
7 | Lock Button | EA | 4833 | |
8 | Lower Brake Rod Assembly (2 required) | EA | ||
Left- Super Low | 93256 | |||
Left- Low | 93257 | |||
Left – Standard | 93258 | |||
Right- Super Low | 93259 | |||
Right- Low | 93260 | |||
Right- Standard | 93261 | |||
9 | Rear Fork Assembly (2 required) | EA | Includes inner/outer fork, lower |
brake
| Left- Super Low| | AS48013| rod assembly, brake pad complete
| Left- Low| | AS48015| and cap)
| Left – Standard| | AS48017|
| Right- Super Low| | AS48014|
| Right- Low| | AS48016|
| Right- Standard| | AS48018|
10| Front Fork Bearing (2 required/fork)| EA| H48026|
11| Front Fork Stem Bolt| EA| H48024|
12| Front Fork| EA| 4825|
13| Axle Bolt| EA| H48020|
14| Wheel Bearing (2 required/wheel)| EA| H48022|
15| Axle Nut| EA| H48021|
16| Brake Pad Complete (2 required)| EA| 76011|
| Hex Adjustment Screw| | |
| Brake Pad Spring| | |
| Pivot Sleeve Screws (2)| | |
| Brass Pivot| | |
| Screw| | |
| Adjustment Screw| | |
| Lever Spring| | |
| Lever| | |
| Brass Lug| | |
17| Wheel Complete, grey (4 required) Wheel
Bearings (2/wheel)
Bearing Spacer| EA| 93282-01|
---|---|---|---|---
17| Wheel Complete, black (4 required) Wheel
Bearings (2/wheel)
Bearing Spacer| g| 93282-02|
18| Plastic Cap Screw Cover (Rear Fork)| EA| H45003|
19| Curb Climber| EA| 4879|
20| Folding Seat Mechanism| EA| P45007|
21| Seat Handle Red| EA| P45008|
22| Seat Pad Set (2 pc)| EA| 93263|
23| Backstrap Complete Backstrap
Backstrap Clamp Screw Backstrap Clamp Nut| EA| 90391|
24| Backstrap Clamp Left
Right| EA| 4880
4881|
25| Handle Grip| EA| 20-024|
26| Wire Basket (not shown)| EA| 4510|
27| Replacement Soft Bag Bracket Kit| EA| 90276| Included with soft bag
28| Soft Zippered Bag Complete| EA| 93280| Standard with rollator
29| Soft Zippered Bag- 5 Pack| EA| 93281|
For 4600 models:
No| Designation (aty/Rollator)| UofM| Art. no| Additional Instructions
| Brake Handle Complete Right (1 required)| EA| |
| Regular| | P45835|
| Tall| | P48555|
| Brake Handle Complete Left (1 required)| EA| |
| Regular| | P48545|
| Tall| | P48565|
| Lower Brake Rod Assembly (2 required)| EA| |
| Left- Super Low| | 76013|
| Left- Low| | 76016|
| Left – Standard| | 76018|
| Right- Super Low| | 76015|
| Right- Low| | 76017|
| Right- Standard| | 76019|
| Soft Bag| EA| 8050145| Only sold in S pack
HUMAN CARE SWEDEN (HQ)
Årstaängsvägen 21B
117 43 Stockholm
Phone:- +46 8 665 35 00
Fax:- +46 8 665 35 10
E-mail: info.se@humancaregroup.com
HUMAN CARE CANADA
10-155 Colonnade Road
Ottawa, ON K2E 7K1
Phone:- 613.723.6734
Fax:- 613.723.1058
Email: info.ca@humancaregroup.com
HUMAN CARE UNITED STATES
8006 Cameron Road, Suite K
Austin, TX 78754
Phone: 512.476.7199
Fax: 512.476.7190
Email: info.us@humancaregroup.com
HUMAN CARE GERMANY
Industriestraße 13, Geb. 1/9
63755 Alzenau
Phone: 06023 9949368
Email: infode@humancaregroup.com
HUMAN CARE NEDERLAND
Elspeterweg 124
8076 PA Vierhouten
Phone: 0577-412171
Fax: 0577-412170
Email: info.nl@humancaregroup.com
www.humancaregroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>