MARLEY Air 4.0 Fresh Air Heat Exchanger Instruction Manual
- June 4, 2024
- MARLEY
Table of Contents
MARLEY Air 4.0 Fresh Air Heat Exchanger Instruction Manual
Please read these assembly and commissioning instructions carefully before starting the installation.
Warnings
Note! Note: All work should be done with no electrical current.
Electrical connections must only be done by an authorized tradesman to the
applicable regulations. Voltage and electrical power supply must be compatible
to the specification of the device. An all pole separator from current with a
contact opening of minimum 3 mm is specified for the installation.
Installation in rooms with high moisture or damp areas must be done according
to DIN/ VDE 0100 T701.
Note! This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
If you operate a fireplace dependent on the room air at the location you intend to use the device, please ensure on all accounts that there is sufficient ventilation, especially if the building shell is airtight.
Please note! During planning, installation and operation, the approval
regulations and the applicable building regulations, the fire protection
ordinance and the accident prevention regulations of the employers’ liability
insurance association must be observed.
Please contact your district chimney sweep if you have any questions.
Further information about this product and the registration documents can be found on the website www.marley.de.
General instructions
*Technical data Marley Air 4.0**
Protection rating/type| II/IP20 inside, II/IP22 outside
Mains voltage| 230V ~ 50 Hz
Motor| 24 V DC, ball bearing mounted
Power input| 2/3/5 Watt
Air power| 19/35/50 m3/h
Heat recovery rate| max. 80 %
Sound pressure (3 m)| 15/23/31 dB(A)
Sound insulation from outside| 38 dB
Transmission power| -9,51 – -9,55 ERP (dBm)
Frequency| 433 – 434 MHz
Battery| CR2025
Subject to technical alterations, specification for one device.
Remote control – description
-
ON/OFF switch
To seal the unit airtight in the event of an official emergency, place the sealing foil located on the inside of the inner panel between the sound wheel and the filter (see section Katastrophenfall in this installation instruction). -
Change-over switch ‒/+
- low fan setting (‒) 50/35/19 m³/h
- high fan setting (+) 19/35/50 m³/h
-
Summer operation
In summer mode, the Marley Air 4.0 switches to Level 1 and the direction of flow is no longer changed.
From this moment onwards, the room air is transported to the outside the whole time.
In dialogue mode, both units switch into Level 1, and in this process, one unit conveys the room air to the outside and the second unit brings fresh air into the room; here too, there is no change in the direction of flow. Summer mode is terminated by pressing the +/‒ button, and the Marley Air 4.0(s) revert(s) to “normal” heat recovery mode.
Maintenance and service
Half-yearly Maintenance Intervals/Service
- Automatic maintenance indicator by the LED display blinking
- After carrying out the service, acknowledge by pressing the control button.
Spare parts
534725 = Control board
534732 = Transformer board
534794 = Motor
535326 = Remote control
701039 = G3 filter set (6x)
701114 = Sound element Ø 145 x 48 mm
Disposal
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the
environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems or contact the
retailer where the product was purchased.
They can take this product for environmental safe recycling.
Declaration of Conformity
Hereby, Marley Deutschland GmbH declares that the radio equipment type Marley Air 4.0 and as well remote control MENVFB are in compliance with Directives 2014/35/EU, 2014/30/EU, 2009/125/EU and 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: