FREDRICK RAMONDO 30811 Agave Medium Convertible Pendant Instruction Manual
- June 8, 2024
- FREDRICK RAMONDO
Table of Contents
FREDRICK RAMONDO 30811 Agave Medium Convertible Pendant
Mounting Instructions
Item No: 30811
start here
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
Shut off electrical Current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead. DO NOT restore current either by fuse, breaker, or switch – until the new fixture is completely wired and in place.
-
Feed wire through stem (S) and canopy (C).
-
Secure stem (S) to coupler (Z) at the top of of fixture.
-
Wiring and mounting of fixture can now be started.
-
To begin installation-Remove mounting plate (A) from canopy (B) by removing the screws on the side of canopy (C)
-
Next secure mounting plate (A) to junction box (J) using two screws (D) (NOT provided)
-
Make electrical connections using IS-18
-
Tuck wires into junction box
-
Secure canopy (B) to mounting plate (A) using screws previously removed (C)
-
Power may now be restored and fixture can be lamped accordingly.
wiring grounding instructions
SAFE TY WARNI NG: READ WIRIN G AND GROUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSU LT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A ) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B ) with appropriately sized twist on connector – see Drawings 1 o r 2.
- Connect negative supply wire (C) (typically white or the ribbed , marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A ) (typically black or the smooth
unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3. -
Connect negative supply wire (C) (typically white or the ribbed , marked side of the two-conductor cord) to negative fixture lead (D).
-
Cove r open end of connector s with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting p late (backplate) and the wall. This will help prevent water fr om entering the out let box . If the wall sur face is lap siding, use caulk and a fixture mounting plat form specially. -
Please refer to the grounding instructions below to completely electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M ) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S ) on fixture mounting strap (M ) and connect to the loo se end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Draw in g 2.
Post-Mount Fixtures
Connect fixture ground wire (E ) (typically copper or green plastic coated) to
power supply ground with app rope irately sized twist-on connector inside
post. Cove r open end of connector with silicone sealant to form a watertight
seal – see Drawing 3.