These instructions are for Vitodens 100 Compact boilers serving central heating and hot water. The weather compensation outdoor sensor can only be used in conjunction with the cylinder demand box supplied. [This is not needed if the installation is for central heating only – without hot water. In this case, use outdoor sensor kit Z006506 instead.] Y-Plan mid-position valves (eg Honeywell V4073A) must be wired to operate as a W-Plan, as described.
Use the Internal wiring diagram overleaf for plug in timers or base stations.
Use the External wiring diagram overleaf for separately mounted equipment.
A room thermostat may be connected in addition to the outdoor sensor.
The outdoor sensor kit (Z007933) consists of:

  • Outdoor sensor
  • Connection lead
  • Cylinder control box

Functions and operating conditions in weather compensated mode
In weather compensated mode, the boiler temperature is regulated subject to the outside temperature. Installation of the outside temperature sensor:

  • North or north-western wall, 2 to 2.5m above ground level; in multi storey buildings, in the upper half of the second floor
  • Not above windows, doors or ventilation outlets
  • Not immediately below balconies or gutters
  • Never render over
  • 2-core lead, max 35m length with a cross-section of 1.5mm2

Option 1: outdoor sensor with external time control

VIESSMANN-Z007933-Outdoor-Compact-Sensor-1

Option 2: outdoor sensor with internal time control (Viessmann accessories)VIESSMANN-Z007933-Outdoor-Compact-Sensor-2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

VIESSMANN User Manuals

Related Manuals