Thank you for purchasing our humidifier YK-MH-2118.
Please read this manual carefully before using and keep it for future reference.
All pictures shown are for illustration purposes only.
Actual products may vary due to product enhancement.

Safety Guide

Please do not disassemble or transform the machine.
Please do not let the machine be strongly impacted.
Please stop the machine before moving it.
Please don’t connect the socket that exceeds the rated voltage and don’t use the extension cable to avoid fire or electric shock.
When the plug or wire is abnormally hot, please stop using it.
Please do not unplug the power plug with wet hands, otherwise, it may cause electric shock or injury.
Please do not block the outlet or add water to the mist outlet which may cause water leakage, deformation or failure.
Please do not use acidic detergent in the main body. If the detergent remains, it may produce toxic gas.
Children should use it under the supervision of adults.
Please do not deliberately inhale the spray mist, especially for people with sensitive respiratory tract.
Please do not put essential oil into the main body/water tank, which may cause water leakage deformation or failure.
Please do not insert your fingers or other things into the water inlet or air outlet or the gap which may cause damage to the machine or electric shock.
When not in use for a long time (more than 24 hours), please pour out the water in the water tank and sink to prevent mold or impurities from harming your health.
Please leave it at room temperature for 30 minutes before the first use to avoid damage to the water tank due to sudden temperature changes.
Please use it at normal room temperature (5°C~40°C).
When the room temperature is lower than 0°C, please pour out the water in the water tank and sink to avoid freezing and damaging the machine.

Components

YOKEKON YK MH 2118 Large Humidifiers - Components

Placement

Please place the humidifier in a horizontal position, at least 50 cm away from walls, furniture, furnace, household appliances, etc.
Please do not use it in the following occasions to avoid water leakage, signal interference or injury, etc.
Direct sunlight.
On the unstable platform.
With high temperatures humidity and dust.
Near the air conditioner, furnace, heater and stove.
Near the radio and other objects that emit radio waves.
Under the table, or on the carpets bedding, etc.
Near mobile phones, computers and other precision instruments.

Installation

  1. Take off the main body, take out the remote control and other accessories in the water tank.YOKEKON YK MH 2118 Large Humidifiers - Take off the main body
  2. Remove the insulating plastic sheet before using the remote control.YOKEKON YK MH 2118 Large Humidifiers - insulating plastic sheet
  3. Remove the protective bag from the water pump.YOKEKON YK MH 2118 Large Humidifiers - Remove the protective bag
  4. Place the main body on the water tank properly.

Water Filling & Accessories Assembly

YOKEKON YK MH 2118 Large Humidifiers - Water Filling

  • Open the lid and add water from the top.
  • Remove the main body and add water to the water tank directly.

Distilled water or RO water is recommended.
Please add water below 40°C.
Please do not exceed the maximum water mark.
Please do not allow water enter the mist outlet or water may enter the inside and cause the machine to malfunction.
Please do not add mineral water, plasma water or tap water that has not been used for a long time. If mold or impurities grow, it may cause health problems.
When the water is insufficient, the machine will prompt water shortage and automatically shut down. Please refill with water and turn it on.

YOKEKON YK MH 2118 Large Humidifiers - Accessories
Assembly

Control Panel & Remote Control

POWER| Touch the button and the display lights up and the humidifier starts to work.
---|---
MAX-MIN| The mist volume can be adjusted in three levels: low, medium, high.
HUMIDITY| The humidity can be set between 40-90% in increments of 5%. The humidifier will automatically stop spraying mist when the surrounding humidity reaches the set value.
SLEEP| Touch the button to enter sleep mode, and the display will be dimmed. Touch any button to exit sleep mode, and the display will light up.
TIMER| The timer can be set for 1-12 hours in increments of 1 hour. The humidifier will shut down automatically when the time reaches the set value.
****UV| Touch the UV button to turn on/off the sterilization feature.

The operation of remote control is the same as the control panel.
Please remove the insulating plastic sheet before using the remote control.
When turning on the UV light, do not look directly at it for a long time, otherwise it may cause eye discomfort.

Maintenance

YOKEKON YK MH 2118 Large Humidifiers - Maintenance

Tilt the main body to this side and pour out the water. Take care not to wet the ground.| Clean the water tank with the sponge weekly.| Clean the sink with the sponge weekly.

When not in use for a long time (more than 24 hours), please pour out the water in the water tank and sink to prevent mold or impurities from harming your health.
Be sure to pull out the power plug before maintaining the humdifier.
Do not directly flush the whole machine with water to avoid short circuits and failure.
With the use of tap water, minerals and organics may adhere to it, which may cause the function of humidifier to decline or malfunction. If the dirt is not easy to clean, the cloth can be soaked in neutral detergent before wiping.
The residue of detergent in the sink and tank should be cleaned up before use.
Make sure the main body is completely dry before use.

FAQ

Q: After the power is turned on, the display does not light up.

– A: There may be water entering the circuit board. Please air-dry the main body for one day. If it still can’t be turned on, please contact customer service by email.

Q: Low mist output.

– A: When the ambient humidity exceeds the set value, the machine will stop spraying mist automatically. But if the atomizer is damaged, please contact customer service by email.

Q: Red light flashing.

– A: Please open the sink and check whether the water can be pumped up. If not, check whether the water pipe has fallen or broken. None of the above, contact customer service by email.

Q: Abnormal noise.

– A: There is too little water in the tank, or the ground is not stable. Please fill water and place the humidifier on a flat and stable surface.

Q: The humidity value is not completely consistent with the room humidity.

– A: There is a built-in humidity sensor in the main body. The humidity difference of 5-10 is within the normal range. If not, please contact customer service by email.

Q: There is white powder around the humidifier.

– A: Tap water contains certain minerals, may adhere to the object, please do not worry and clean the water tank regularly. Keep the precision instrument away from the humidifier to avoid damage to them.

Q: There is scale in the water sink or tank.

– A:  Tap water contains certain minerals, may adhere to the object, please do not worry and clean the water sink and tank regularly.

Q: Interference with TV remote control signal.

– A: Keep the humidifier 1m away from the TV or other objects that emit radio waves.

Q: The floor is wet or there is water around the humidifier.

– A: Humidity is too high, or the humidifier is placed in a non-ventilated place, so the mist can not be fully evaporated.

Q: The fire on the stove turned red.

– A: Because the composition of the tap water reacts with the flame(Flame reaction), please keep the humidifier away from the stove.

Q: Why didn’t the humidifier generate mist ?

– A: It needs to wait 40-60 seconds to generate mist every refilling.

Product Specifications

YOKEKON YK MH 2118 Large Humidifiers

Product Name Ultrasonic Humidifier
Model Number YK-MH-2118
Operation Mode Low    Medium   High
Rated Power 110W
Rated Voltage 110V-240V~
Max Mist Output 2000mL/h
Noise ≤35dB
Tank Capacity 4.49Gal / 17L
Size 2952251150mm
N.W. 4.2Kg
Safety Functions 1-12 hours timer

Waterless auto shut-off
Automatic shutdown when falling

Warranty Period
Our company provides a one-year warranty, which starts from the date of purchase.
When returning the product, please confirm that the product is intact, and the packing boxes and accessories are complete.
Non-Warranty Policy
The following conditions are not covered by the warranty.
Over the warranty period.
Damage caused by natural disasters and other force majeure.
Any damage caused by use not in accordance with the requirements in the User Manual.
Failure or damage caused by forced use of the product.
The user disassembles or repairs the product without authorization.
Warranty Requirements

  1. Please provide the warranty card and the order number.
  2. Please describe the problems in details with pictures or videos.
  3. Send e-mail to service@yokekon.com

Sorry that warrant service would not be available if you are unable to provide the above information.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals