DiLusso TH602MSL Telescopic Hood 600MM Instruction Manual
- June 8, 2024
- DiLusso
Table of Contents
TH602MSL Telescopic Hood 600MM
Instruction Manual
TELESCOPIC HOOD
INSTALLATION MANUAL
USER MANUAL
TH602MSL Telescopic Hood 600MM
Read this manual carefully before operation to avoid risk of accident or
damage to the appliance
Images in this manual are for reference only, refer to physical unit for exact
dimensions.
Congratulations on the purchase our cooker hood. Before installing and/or
using the cooker hood carefully read all the instruction.
IMPORTANT NOTES
**** The instructions for use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance.
INSTALLATION
The manufacturer will not be held liable for any damages resulting from
incorrect or improper installation.
The minimum safety distance between the cooker top and the extractor hood is
650 mm (some models can be installed at a lower height, please refer to the
paragraphs on working dimensions and installation).
Check that the mains voltage corresponds to that indicated on the rating plate
fixed to the inside of the hood.
For Class I appliances, check that the domestic power supply guarantees
adequate earthing.
Connect the extractor to the exhaust flue through a pipe of minimum diameter
125mm. The route of the flue must be as short as possible. Do not connect the
extractor hood to exhaust ducts carrying combustion flumes (boilers,
fireplaces, etc.).
If the extractor is used in conjunction with non-electrical appliances (e.g.
gas burning appliances),a sufficient degree of air circulation must be
guaranteed in the room in order to prevent the backflow of exhaust gas. The
kitchen must have good ventilation to guarantee the entry of clean air. When
the extractor hood is used in conjunction with appliances supplied with
energy other than electric, the negative pressure in the room must not exceed
0,04 mbar to prevent fumes being drawn back into the room by the extractor
hood.
In the event of damage to the power cable, it must be replaced by the
manufacturer or by the technical service department, in order to prevent any
risks.
If the instructions for installation for the gas hob specify a greater
distance specified above, this has to be taken into account. Regulations
concerning the discharge of air have to be fulfilled.
USE
The extractor hood has been designed exclusively for domestic use to eliminate
kitchen smells.
Never use the hood for purposes other than for which it has been designed.
Never leave high naked flames under the hood when it is in operation. Adjust
the flame intensity to direct it onto the bottom of the pan only, making sure
that it does not engulf the sides.
Deep fat fryers must be continuously monitored during use: overheated oil can
burst into flames.
Do not have a naked flame under the extractor hood due to risk of fire.
This appliance is not intended for use by persons (including children) with
reduce physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they are being supervised or given instructions concerning
the use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
“CAUTION: Accessible parts may become hot when used with cooking
appliances”.
MAINTENANCE
Switch off or unplug the appliance from the mains supply before carrying
out any maintenance work.
Clean and/or replace the Filters after the specified time period (Fire
hazard).
****Clean the hood using a damp cloth and a neutral liquid detergent.
The symbol on the packaging indicates that this product may not be treated as household waste. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences on the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
COMPONENTS
Ref. | Qty | Product Components |
---|---|---|
1 | 1 | Hood Body, complete with: Controls, Light, Motor, Filter. |
2 | 1 | Butterfly valve |
3 | 2 | The Activated Charcoal filter (1 / 2 optional ) |
4 | 4 | Screws 5 x 50 |
5 | 4 | Wall Plugs |
DIMENSIONS
INSTALLATION
METHOD 1
Referring to the above diagram, align the position of the hood with the
cabinet. Insert the 4 screws (supplied) into the screw holes and tighten.
Screws should be fastened firmly, ensure that the hood is securely fastened to
the cabinet and is stable before using.
Warning
When cutting or drilling into wall or ceiling, do not damage electrical wiring
or other hidden utilities.
METHOD 2
To mount on the wall, insert and secure 2 screws (supplied) into the relative
position of the 2 screw holes on the back of hood.
Also install screws in the security hole positions, to further stabilise the
hood.
Ensure hood is secure and stable before using.
Warning
Warning
The extractor hood must not be installed and connected to flues where other
appliances are installed and share power connection with other appliances
VENTING MODES
If your hood has dual mode extraction, locate the venting knob on the front
of the motor casing. Select extraction mode.
| Ducted mode: Exhaust is extracted outside the house.
---|---
| Recirculating mode: Exhaust is filtered and recirculated inside.
DUCTED MODE
Insert the butterfly valve into the flue hole, and turn clockwise to
secure. The butterfly valve must be used for ducted mode.
When installing the ducted version, connect the hood to the outlet vent using
either a flexible or rigid pipe ɸ 150 or ɸ 120 mm, the choice of which is left
to the installer.
To install a ɸ 120 mm air exhaust connection, insert the reducer flange on the
hood body outlet over the butterfly valve. Fix the ducting using sufficient
pipe clamps (not supplied). Use minimal bends in the ducting for optimal
power, increasing bends may reduce performance of your hood
Ducting can extend either through the wall or the roof. Do not terminate the
vent system in an attic or other enclosed areas.
Remove possible charcoal filters.
RECIRCULATING MODE
The butterfly valve does not need to be installed when using recirculating
mode.
Ensure the venting knob points to recirculating mode and the vents in front of
the hood are not blocked when hood is use. Ensure both charcoal filters and
aluminum filters are installed. Charcoal filters need to be replaced at
regular intervals, refer to Maintenance section.
HOW TO USE
Before using
Check the condition of the appliance:
Check whether there are visible defects.
Check that all parts of the appliance have been securely fitted.
Switching on/off
Pull out the fascia and locate the switches on the right.
There are 2 speeds for the motor and on/off switch of the light.
Motor Operation
[O]=Off
[ ]=Low Power Setting
[ ]=High Power Setting
Light Operation
[ ]=Off
[ ]=On
MAINTENANCE
GREASE FILTERS
CLEANING ALUMINIUM FILTERS
The filters must be cleaned every month of operation, or more frequently for
particularly heavy usage, and can be washed in a dishwasher.
Press the anchoring hinge to release them.
Remove the filters one by one pushing them towards the back side of the hood
unit and simultaneously pulling downwards. Do not bend the filters. Before
fitting them again into the hood make sure that they are completely dry. (The
color of the filter surface may change over time but this has no effect on
the filter’s efficiency).
When re-fitting the filters into the hood ensure they are mounted in the
correct position and the anchoring hinge is at the front.
ACTIVATED CHARCOAL FILTERS (RECIRCULATING MODE)
These filters are not washable and cannot be regenerated, and must be replaced
approximately every 4 months of operation, or more frequently with heavy
usage. Contact the retailer or manufacturer to purchase replacements.
Remove the aluminum filters
Remove the saturated activated charcoal filters.
Fit the new charcoal filters.
Reinstall the aluminum filters.
IMPORTANT
**** When activated carbon/charcoal filters are attached, the suction power
maybe compromised.
LIGHTING
LIGHT REPLACEMENT
Changing the light
Lightning inside the appliance is provided by a 1.5W LED light.
To replace the LED light, proceed as follows:
- Disconnect the appliance from the mains or switch off the circuit breaker.
- Remove the metal filters (see Cleaning and Replacing Filters) .
- Remove the light by levering its fitting from the hood body(this may require pressure or force to be applied) and disconnect the connector of the light.
- Replace the light with a n ew one of the same type, making sure that you connect the light with the light cable correctly.
- Install the metal filter back in place.
| Max power| Voltage| Picture| Lamp Cap| ILCOS D code
---|---|---|---|---|---
Self-ballasted LED modules| 1.5W| 220-240V|
Square/Diameter:33.2mmx120mm
| /| DBS-1.5-H-33.2/120
DISPOSAL OF ELECTRICAL APPLIANCES
The European directive 2012/19/EU on Waste Electrical and Electronic Equipment
(WEEE), requires that old household electrical appliances must not be disposed
of in the normal unsorted municipal waste stream. Old appliances must be
collected separately in order to optimize the recovery and recycling of the
materials they contain, and reduce the impact on human health and the
environment.
The crossed out “wheeled bin” symbol on the product reminds you of your
obligation, that when you dispose of the appliance, it must be separately
collected.
Consumers should contact their local authority or retailer for information
concerning the correct disposal of their old appliance.
TROUBLE SHOOTING
Symptoms | Possible Cause | Action |
---|---|---|
Does not function | No electrical supply | Check that the plug is connected. |
Check that the main switch is turned on.
Poor airflow| Aluminum filters grease clogged| Clean the filters and replace
when it is dry
Charcoal grease filters clogged| Replace charcoal filters with new sets
Motor running but no airflow| Butterfly valve jammed| Contact technician
Motor cuts after a few minutes| High temperature safety device activated| The
kitchen is not sufficiently ventilated
The hood is installed too near the cooking stove| The hood must be at least
65cm from stove
Strong cooking smell| Charcoal filters not installed| In re-circulating mode,
charcoal filters must be installed
Oil dripping onto stove| Aluminum grease filter saturated| Wash the aluminium
grease filters
Aluminum grease filter saturated| Wash the aluminium grease filters
Whirring sound| Foreign object in contact with fan blade| Contact technician
V1.2
P/N:16173000A16207
Documents / Resources
|
DiLusso TH602MSL Telescopic Hood
600MM
[pdf] Instruction Manual
TH602MSL Telescopic Hood 600MM, TH602MSL, Telescopic Hood 600MM, Hood 600MM
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>