VIKING E-1600BLT2IPEWP VoIP Tower Phones Instruction Manual

June 4, 2024
VIKING

Designed, Manufactured and Supported in the
USAPRODUCT MANUAL

VoIP Tower Phones
ADA Compliant VoIP Emergency Tower Phones December 22, 2021

ADA Compliant VoIP Tower Phones with

Blue LED Beacon and Strobe Light
The E-1600-BLTIPEWP, E-1600BLT2IPEWP, E-1600-ASTIPEWP and E-1600AST2IPEWP ADA Compliant VoIP Emergency Tower Phones are designed to provide quick and reliable handsfree communication for SIP VoIP phone systems with PoE. The tower phones meet ADA requirements for emergency telephones and can be programmed from any touch-tone phone or PC on the same LAN or remotely using a static IP address. The phones can dial up to 5 programmable emergency numbers. In addition, the E-1600BLT2IPEWP and E-1600AST2IPEWP feature a second “INFO” button that will dial up to 5 non-emergency numbers.
At the simple push of a button, the Tower Phone will initiate a call to your emergency personnel and send a digital announcement to identify the location of the emergency call. In addition, the tower phone’s bright LED strobe light will instantly begin flashing to deter further activity and make it fast and easy for Police or Security personnel to locate the site of the emergency. The strobe light can also be programmed to provide a continuous-on lower intensity beacon when the emergency phone is not in use. All four Tower Phone Models are equipped with Enhanced Weather Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. EWP products are designed to meet IP66 standards and may feature foam rubber gaskets, sealed connections, gel-filled butt connectors, as well as potted circuit boards with internally sealed, field-adjustable trim pots and DIP switches for easy on- site programming. For more information on EWP, see DOD 859.
Installation requires the assistance of a Network Administrator / IT Technician.

VIKING E 1600BLT2IPEWP VoIP Tower Phones

Features

  • Automatic polling and programming software included

  • SIP compliant (see page 2 for compatible SIP servers and IP phone systems)

  • Outbound Proxy, Authentication ID, Peer to Peer, VLAN Tagging

  • PoE powered (class 1, <4 Watts)

  • Automatic Noise Canceling (ANC) for operation in noisy environments

  • VoIP eliminates the need for “Push to Talk” mode

  • Network downloadable firmware

  • Meets ADA requirements for Emergency Phones:
    – Automatically lights the “Call Connected” LED
    – Transmits a location I.D. or voice announcement
    – Grade 2 Braille label for the visually impaired

  • Non-volatile digital voice announcer with 28 seconds of voice memory

  • Handsfree operation

  • Marine grade 316 stainless steel prevents faceplate/push button corrosion

  • Dials up to 5 emergency numbers

  • E-1600BLT2IPEWP and E-1600AST2IPEWP can also dial up to 5 additional non-emergency “INFO” numbers

  • Cycles through backup phone numbers on busy or no-answer

  • Comes standard with Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating, see DOD 859

  • Hangs up on busy signal, time-out or touch-tone command

  • Remotely programmable

  • Extended temperature range of -40°F to 140°F

  • Optional PB-100 Polling System available (DOD 232)

  • Diagnostics for the testing microphone, speaker, and relay.

Applications

  • Campus Security Sites
  • Area of Refuge sites
  • Parking Ramps/Lots
  • Automated Tellers (ATM)
  • Entryways
  •  Roadside Emergency Sites
  • Stairwells in Public Buildings

www.VikingElectronics.com Information: 715-386-8861

Specifications

Phone Power: PoE class 1 (<4 Watts)
Beacon/Strobe Power: 120VAC / 12VDC power adapter (included)
Maximum Sound Pressure: 90 dB SPL @ 1m
Dimensions: See Installation and Specifications
Operating Temperature: -40°F to 140°F (-40° C to 60° C)
Humidity: Up to 100%
Audio Codecs: G711u, G711a, G722
Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with auto cross over
Connections: (1) RJ45 10/100 Base-T, (3) gel-filled butt connectors

VoIP SIP System Compatibility

For compatibility and vendor-specific detailed configuration instructions, see the Viking VoIP SIP System Compatibility List, DOD 944. To open and download this PDF file:
Scan the QR code below to open and download the Viking VoIP SIP System Compatibility List
– OR –

  1. Go to www.vikingelectronics.com and enter 944 in the search box
  2.  Click Application Note (DOD 944) to open and download the PDF

https://www.vikingelectronics.com/wp- content/uploads/documents/application_note/VoIP-Compatibility944.pdf

Important: Exclusion from this list means only that compatibility has not been verified, it does not mean incompatibility. If you have questions, please call Viking Electronics at 715-386-8861.

Definitions

Client: A computer or device that makes use of a server. As an example, the client might request a particular file from the server.
DHCP: Dynamic Host Configuration Protocol. In this procedure, the network server or router takes note of a client’s MAC address and assigns an IP address to allow the client to communicate with other devices on the network. DNS Server: A DNS (Domain Name System) server translates domain names (ie: www.vikingelectronics.com) into an IP address.
Ethernet: Ethernet is the most commonly used LAN technology. An Ethernet Local Area Network typically uses twisted pair wires to achieve transmission speeds up to 1Gbps.
Host: A computer or device connected to a network.
Host Name: A hostname is a label assigned to a device connected to a computer network that is used to identify the device in various forms of network communication.
Hosts File: A file stored in a computer that lists host names and their corresponding IP addresses with the purpose of mapping addresses to hosts or vice versa.
Internet: A worldwide system of computer networks running on IP protocol that can be accessed by individual computers or networks.
IP: Internet Protocol is the set of communications conventions that govern the way computers communicate on networks and on the Internet.
IP Address: This is the address that uniquely identifies a host on a network.
LAN: Local Area Network. A LAN is a network connecting computers and other devices within an office or building.
Lease: The amount of time a DHCP server reserves an address it has assigned. If the address isn’t used by the host for a period of time, the lease can expire and the address can be assigned to another host.
MAC Address: MAC stands for Media Access Control. A MAC address, also called a hardware address or physical address, is a unique address assigned to a device at the factory. It resides in the device’s memory and is used by routers to send network traffic to the correct IP address. You can find the MAC address of your E-1600-BLTIPEWP/E-1600BLT2IPEWP phone printed on a white label on the top surface of the PoE LAN port.
Router: A device that forwards data from one network to another. In order to send information to the right location, routers look at IP Address, MAC Address and Subnet Mask.
RTP: Real-Time Transport Protocol is an Internet protocol standard that specifies a way for programs to manage the real-time transmission of multimedia data over either unicast or multicast network services.
Server: A computer or device that fulfills requests from a client. This could involve the server sending a particular file requested by the client.
Session Initiation Protocol (SIP): Is a signaling communications protocol, widely used for controlling multimedia communication sessions such as voice and video calls over Internet Protocol (IP) networks. The protocol defines the messages that are sent between endpoints, which govern the establishment, termination and other essential elements of a call.
Static IP Address: A static IP Address has been assigned manually and is permanent until it is manually removed. It is not subject to the Lease limitations of a Dynamic IP Address assigned by the DHCP Server. The default static IP Address is: 192.168.154.1
Subnet: A portion of a network that shares a common address component. On TCP/IP networks, subnets are defined as all devices whose IP addresses have the same prefix. For example, all devices with IP addresses that start with 100.100.100. would be part of the same subnet. Dividing a network into subnets is useful for both security and performance reasons. IP networks are divided using a subnet mask.
TCP/IP: Transmission Control Protocol/Internet Protocol is the suite of communications protocols used to connect hosts on the Internet. TCP/IP uses several protocols, the two main ones being TCP and IP. TCP/IP is built into the UNIX operating system and is used by the Internet, making it the de facto standard for transmitting data over networks.
TIP: Telephone Internet Service Provider
WAN: Wide Area Network. A WAN is a network comprising a large geographical area like a state or country. The largest WAN is the Internet.
Wireless Access Point (AP): A device that allows wireless devices to connect to a wired network using Wi-Fi, or related standards. The AP usually connects to a router (via a wired network) as a standalone device, but it can also be an integral component of the router itself. Wireless Repeater (Wireless Range Extender): takes an existing signal from a wireless router or access point and rebroadcasts it to create a second network. When two or more hosts have to be connected with one another over the IEEE 802.11 protocol and the distance is too long for a direct connection to be established, a wireless repeater is used to bridge the gap.

Features Overview

VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG

Installation and Specifications

VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG 1

Step 1.| Mount the tower phone approximately 42” above the floor to a flat, sturdy surface using 5/16 hardware. Note: Flat washers should be used on the main mounting bolts for additional strength.
---|---
Step 2.| Locate the strobe light panel and attach red, black and green 42” wire extensions with butt connectors then pass the red, black and green wires from the strobe panel through the gasket and the upper hole in the tower.
Step 3.| Mount the strobe panel to the tower using the four security screws provided. Attention: To make sure water drain notch between stobe and panel is facing down, attach strobe panel with wires exiting left side of panel.
Step 4.| Locate the phone panel. Using the gel-filled butt connectors, wire the Strobe Light to the Phone panel as shown on Page 6.
Step 5.| Connect CAT 5 or greater Ethernet cable to RJ45. (See Page 8)
Step 6.| Mount the phone panel to the tower using the remaining four security screws.

Wiring

IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line. It is recommended that a surge protector be installed to protect against such surges. VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG
2

Programming the SL-2 Stobe / Beacon

The SL-2 can be user programmed as a Beacon only, Strobe only or Beacon/Strobe. The brightness setting can be programmed separately for the Strobe or Beacon and one of 4 different Flash Patterns can be programmed for the strobe (see Strobe Flash Patterns, on page 7). Note: The SL-2 is factory default programmed as a steady on beacon with a
single flash strobe when activated. The beacon and strobe are set to their brightest settings. All programming should be done prior to connecting to the 2 amp relay contacts on the 1600-IP PCB. A. Accessing the Programming Mode
(Optional, the SL-2 is factory programmed to the Beacon/Strobe Mode and brightest Beacon/Strobe settings).

Step 1. Apply 10-15 VDC power to the Red (+) and Black (-) wires.
Step 2. Touch and hold the Green (Control) wire to the Black (-) wire for 3

seconds. The strobe should flash twice.
You are now in Programming mode. Note: Once in the programming mode, if a programming command
has not been entered for 20 seconds the strobe will flash 3 times indicating the unit has exited programming
and returned to the Run Mode.

B. Programming Desired Features (after accessing the Programming Mode as shown on page 6)
Select the Feature: Momentarily touch the Green (Control) wire to the Black (-) wire 1 to 10 times to select which feature to program, see Programming Features List to the right. The strobe should momentarily flash each time the Green (Control) wire has touched the Black (-) wire.
Features 1-3 & 6-10: After selecting Programming Features 1-3 or 6-10, wait 3 seconds and the strobe should flash 2 times indicating that feature has been programmed. You can now exit programming or move on to programming the Beacon or Strobe brightness settings. Setting Strobe Brightness (factory set to 6/Brightest): After selecting Programming Feature 4 (Strobe Brightness), wait 3 seconds and the strobe should begin flashing in the preprogrammed flash pattern. Touch and hold the Green (Control) wire to the Black (-) wire. The SL-2 will begin flashing the strobe cycling through 6 different brightness settings from lowest to highest. When the SL-2 flashes at the desired brightness level immediately remove the Green wire from the Black. The SL-2 should flash twice indicating the selected brightness level has been set.
Setting Beacon Brightness (Factory set to 6/Brightest): After selecting Programming Feature 5 (Beacon Brightness), wait 3 seconds and the beacon will light at its preprogrammed beacon brightness setting. Touch and hold the Green (Control) wire to the Black (-) wire. The SL-2 will begin stepping through 6 different beacon brightness settings from lowest to highest. When the SL-2 lights at the desired beacon brightness level immediately remove the Green wire from the Black. The SL-2 should flash twice indicating the selected brightness level has been set.
Exiting Programming: To exit programming simply wait 20 seconds from the last programming command and the unit will flash 3 times. This indicates the SL-2 has exited
the programming mode and is now in the Run mode. Note: To eliminate waiting 20 seconds, you can also exit programming after the last programming command by touching and holding the Green (Control) wire to the Black (-) for 3 seconds. The strobe will flash 3 times indicating the unit has exited the programming mode and is now in the Run mode.
Programming Features List

Number Description
1 Beacon/Strobe (factory default)
2 Strobe Only
3 Beacon Only
4 Strobe Brightness 1-6 (factory default = 6, brightest setting)
5 Beacon Brightness 1-6 (factory default = 6, brightest setting)
6 Single Flash Strobe (factory default)
7 Double Flash Strobe
8 Quad Flash Strobe
9 Flicker Flash Strobe
10 Reset to Factory Default Settings

C. Strobe Flash PatternsVIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG
3

Typical Installation on SIP Based VoIP Phone System

Viking
E-1600-BLTIPEWP
Emergency Phone

VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG 4

  • Note: A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles) an ethernet to fiber media converter can be used.

PC Requirements

  • IBM compatible personal computer with: Windows 7, 8 or 10
  • Adobe Acrobat Reader 8 or higher
  • VoIP Tower Phone hardware
  • Available LAN with PoE (class 1, < 4 watts)
  • Ethernet cable ( CAT5 min.)
  • 1 MB minimum free hard drive space for installation
  • 16MB of free physical RAM

PC Programming

Download and install the programming software

  1. Go to www.vikingelectronics.com and enter E-1600-BLTIPEWP in the search box
  2. Click E-1600-BLTIPEWP in the search results
  3. Scroll down the page to Downloads, click IP Programming Software
  4. Install the programming software by saving or opening the file and then clicking on setup Viking IP Programming.exe
  5. Follow the prompts on your screen to complete the software installation
  6. To start the Viking IP Programming application, click on the Viking IP Programming icon on your desktop. The Main screen will appear, allowing the user to program any VoIP Tower Phone connected to that LAN.
    Note: PC must be connected to the same LAN as the VoIP Tower Phone.

A. Connect / Disconnect
Open the “Viking IP Programming” software on the PC and the start screen shown below will appear. Any Viking IP phones that are connected to the network will appear on the list. Simply select the VoIP Tower Phone on the list and click on the “Connect” button at the bottom or double-click the selected phone. If the security code of the selected phone is still set to default (845464), the PC software will not require entering a security code to connect to the phone. VoIP Tower Phones have a default name of “VIKING_MK64_Vik02”, so if many phones are connected to the same network that all have the default name, MAC addresses must be used to identify each phone. When finished programming, click on the “Disconnect” button at the bottom. Closing the program will also automatically disconnect the unit.VIKING E 1600BLT2IPEWP VoIP Tower Phones -
FIG5 B. Manually Muting SIP/Network Failure Alarm Beeps (3 beeps repeated every 30 seconds)
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30 seconds and turn the Call/Call Connected LED on and off once per second indicating a SIP registration failure, failure to receive an echo reply from a pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and holding the Call button for 5 seconds (2 beeps will then be heard) or by clicking the “Mute Alarm Until Next Failure” tab in the Viking IP programming software. The LED will continue to flash allowing you to troubleshoot the failure.
C. Configuring the VoIP Tower Phone Network Settings

Step 1.| Open the “Viking IP Programming” software on a windows PC that is connected to the same LAN as the VoIP Tower Phone to be programmed.
---|---
Step 2.| The window in the upper left corner of the menu will show you each VoIP Tower Phone that is connected to that LAN. Select the unit with the same MAC address shown on the label located on the top of the Ethernet connector on the VoIP Tower Phone.
Step 3.| Click the “Connect” button. If a pop up window appears, enter the unit’s security code (factory set to 845464) then click “OK”.
Step 4.| The program will then read and display the VoIP Tower Phone’s IP and programming settings.
Step 5.| Click on the “IP Settings” tab.
Step 6.| Select the appropriate value Static IP Settings or DHCP for “Set Unit IP Address via”. Note: changing the IP address will cause you to have to reconnect to the unit. Enter the values for the fields in “if DHCP fails” or “Static IP Settings” as needed.
Step 7.| Set the “Unit Name”, “Logging / Time Server Settings” as needed.
Step 8.| Select Peer-Peer in the “SIP Server / Peer to Peer Settings” to use the unit in Peer to Peer mode. Select Server to register with a SIP registrar server and fill in the “Outbnd Proxy” (SIP Outbound Proxy Server Address, “ip:port”), “Authentic. ID” (SIP Authentication ID), “Username” (SIP Username,

), “Password” (SIP Password), and “Caller ID” (SIP Caller ID) with values from your VoIP provider.

VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG 6

Example 1: On-Premise SIPPhone System
(Panasonic TDE 100/200)| Example 2: Cloud BasedService Provider (Voip.ms)| Example 3: Cloud-Based Service Provider requiring
Outbound Proxy and Authentication ID (Ring Central)
---|---|---
| |

D. Configuring VoIP Tower Phone VLAN Settings

Step 1. Click on the “VLAN” tab
Step 2. Disable or enable VLAN tagging by setting the value of “VLAN

Tagging”.
Step 3.| Set the VLAN tag ID by selecting an integer (1 to 4094) in “ID for all packets”.
Step 4.| Set the Priority Code Point (PCP) value for all not SIP and RTP packets in the “PCP for all packets” input (0 is default, priorities are from low to high: 0, 1, 2, 3, 4, 5, 6, 7). Set the “PCP for SIP packets” (3 is default). Set the “PCP for RTP packets” (5 is default).

VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG 10 E. Manually Resetting the Security Code to Enter Programming

Step 1.| Power down the VoIP Tower Phone by disconnecting the LAN Cable (RJ45 plug).
---|---
Step 2.| Press and hold the call button, then reconnect the LAN Cable (RJ45 plug).
Step 3.| Continue to hold Call button until you hear 2 beeps, (approximately 6 seconds). Then release the button. The LED will remain off for the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2 beeps), indicating when to release button.
Step 4.| The security code is now reset to 845464 (factory default).
Step 5.| You can now enter programming by following the steps in section A.

F. Manually Resetting All Network Parameters to Factory Default

Step 1.| Power down the VoIP Tower Phone by disconnecting the LAN Cable (RJ45 plug).
---|---
Step 2.| Press and hold the Call button, then reconnect the LAN Cable (RJ45 plug).
Step 3.| Continue to hold t he Call button until you hear 2 beeps, (approximately 6 seconds). Continue to hold reset button until you hear 4 more beeps, approximately 6 seconds later, then release the button. The LED will remain off for the first 3 seconds, flash slowly for 3 seconds (2 beeps), fast flash for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4.| You can now enter programming by following the steps in section A.

Programming Features Index

DESCRIPTION Section Page
ComectOtscennect A 9
VLAN Seines D 11
Unit Name 1 13
SIP Server 2 13
Peat Peer &dings 3 13
Outtourd Proxy 5 13
Autnereicaoon 0 6 13
Rellizier Fats 7 13
Speed Dial NUfnterS 8 10
Stokely code (factory hi lo 045404) 9 14
ID Hunter 10 I4
Access Code (1 . 0 Odic blank – disabled, factory Sal to 123450) 11 14
Audo Fite 12 14
ReCOrOino Emergency Announce/To-al hem an alone 13 14
Internal / External Relay (factory set to Internal) 14 15

Relay Mode (Door Strike. Outbound Call. In / Onsand Cat Deonaell, LV-IK Contra. Ring. Red ann. factory set to Dooretaxe ]| 15| 15
Relay AcIlvalon Canmand (I a2 cligits. factory sotto SonNOM Rehm Mode must be set to Doorstieto| 16| 16
Relay Activation Time (0 5.99  seconds. factory set to 3 seconds)| 17| 10
Relay BOLT Vahan. II – 3 a Disabled. factory set to 3)| 18| 16
Reay Latch Commands (Enabled or Disabled. factory sal to Enabled) NOTE: Reray Mole musE be set 10 Door Strike| 19| 10
Aremating Svelich A011041| 20| 16
Speaker Mode (ON. OFF / Solent Monitor or OFF until Answered. factory set lo ON)| 21| 10
Speaker Volume (0 – S. faddy Set to 1)| 22| 16
FUN: Yawn° (0. 9. factory set to 5)| 23| 10
Microphone Volume (0 – S. 0 4 Auto. Nasty set lo 5)| 24| 17
Toult.14ten Delay (VOX) (0 1 . 0.9 hornet, factory Set 100 D SeCOndal| 25| 17
bland Audio Call Prowess (Enabled. Disabled. factory set to Enabled)| 26| 17
In-Sand Audio Detect SenativItY II – 9. I – mourn. 9 – maxima-0 factory set to 5. power Cycle unn after Senna)| 27| 17
Repeal Announcement Cipta| 28| 17
Lap Counter ( 1 . 9 or 13.1saded. factory set to Dahled)| 29| 17
Call Lenge”. Time Out (di bled or 1 – 9 minutes. factory sell 3 mins)| 30| 17
Inbound Cal Mode r Dleatried. Auto Answer. Auto Answer.Secure. Ring. Rini: nen AGC. Factory rat to Auto Anxwer I| 31| l7
Ring Cadence (faclorty sal to Normal. 2 secretes on 4 seconds on)| 32| 18
Dial Next Number on RNA r Rib No Areareo(drsabled. 1 . 9 – number of rings. factory set 10 7)| 33| l8
Dial Ned NuMber on may (disabled Of enabled. factory set to enabled)| 34| 18
Send ID Marlton as (RFC 2033 or in Band OTMF. Factory set to RFC 20331| 35| l8
Call LED Mode (OFF. Enby Plume. Emergency Phone or Emergency Outbound only. Wiry set to Entry Prone)| 36| 19
Cal LEO Control (Aulornalle or enter
to Pent factory set to Automate)| 37| 19
Mute Current/ Next Atom| 38| 19
Permanent Harm Mute (factory set to Alarm Tones Enabled)| 39| 20
IP Firmware| 40| 20
Um Firmware| 41| 20
ImearbEsecd| 42| 20
Clear Phone Servings| 43| 20
Clear IP SetUngs| 44| 20
Oizonoslics (used to check mt. Shaker and relay OperatiOnS)| 45| 20

Programming Features

  1. Unit Name
    Up to a 31-character unit name can be assigned to the VoIP Tower Phone being programmed.

  2. SIP Server
    Enter the IP address or URL of your SIP server or service provider in this field. The SIP server IP address is limited to 74 characters. Note: If an alternate SIP server IP address is programmed, the IP address for the SIP server and alternate SIP server will be limited to 31 characters. Note: If the outbound proxy is not required, enter the SIP server IP address into the Outbound Proxy field.

  3. Peer-to-Peer Settings
    When set to Peer to Peer mode, a SIP server is not used. The unit should be programmed with a Static IP Address and Username, a password is not used. Caller ID can be programmed if needed. Simply call the unit by entering the programmed “username@192.168…(Static IP address for the unit)”. The static IP address is normally programmed into a page button on the VoIP telephones.

  4. Outbound Proxy
    If your SIP provider requires an outbound proxy IP address enter it in the Outbound Proxy field. If the outbound proxy is not required enter the SIP server IP address into the Outbound Proxy field. Note: If not required, this field must match your SIP server IP address.

  5. Authentication ID
    If your SIP provider requires an Authentication ID, enter it in the Authentic. ID field. If Authentication ID is not required, leave this field blank.

  6. Register Fails (Re-Resolve or Alternate Server)
    When registered to a SIP server in the event that registration is lost you can program the unit to re-resolve using the current SIP server IP address or route pages through an alternate SIP server. With Alternate Server selected enter the IP address of the alternate SIP server in the field next to the Register Fails drop-down box. Note: With an alternate SIP server IP address programmed, the IP address for the SIP server and alternate SIP server will be limited to 31 characters.VIKING E 1600BLT2IPEWP VoIP Tower Phones -
FIG12 Note: A majority of the features below can also be Touch Tone (In-Band DTMF) programmed. See DOD 949.

  7. Speed Dial Phone Numbers
    Note: Up to 79 digits can be stored in each of the 5 speed dial phone number positions. The number programmed in the first location under “Speed Dial Numbers” is the telephone or extension number that is dialed when the call button is pressed. Additional numbers (if programmed) will be dialed when there is no answer and the Dial Next No. on Ring No Answer feature is enabled. The VoIP Tower Phone will also detect busy and move on (Dial Next Number on Busy Enabled). The VoIP Tower Phone will cycle through the programmed Speed Dial numbers until answered.

  8. Security Code
    The security code allows the user/installer to program the VoIP Tower Phone. It is recommended that the factory set security code be changed. Factory Setting: 845464
    Note: The security code must be 6 digits and cannot include a Q or a #.

  9. ID Number:
    The ID Number (1 – 6 digits) is used by emergency personnel to identify the location of the caller and is given out when the receiving party presses a Q. This ID number is transmitted as In-Band DTMF. This can be cleared out by leaving the field blank. Factory Setting: 987654

  10. Access Code
    The Access Code is used for remotely operating the relay (Doorstrike, Mag- Lock, etc) by calling into the unit. This code provides basic security and only allows the operation of the relays and not the ability to change any of the programming parameters. Once entered, any of the “Remote Access Operation Commands” can be used. The code can be 1 – 6 digits in length and cannot contain a “Q” or “#” or match the numbers used for the security code. Simply call the VoIP Tower Phone (set to auto-answer/auto-answer secure), the unit will automatically answer the line and output one beep. You then enter the programmed 1 – 6 digit access code, 2 beeps should be heard. You can now enter any “Remote Access Operation Commands” (see page 21). This code will also enable audio to/from the speaker and the caller. The access code can be cleared (by leaving the field blank) if this additional level of security is not required. Factory Setting: 123456

  11. Audio File (optional)
    The VoIP Tower Phone Emergency Announcement can be uploaded with any user- edited WAV file. See “WAV File Guidelines” below. Alternatively, the announcement can be recorded via a telephone call (See section 12 below). WAV File Guidelines:

1 The WAV file should be 8 or 16 bit PCM mono or stereo.
2 Sampling rates of 8k,16k or 32kHz are acceptable.
3 The WAV file may be stereo or multi-channel, but only the Left Channel will

be loaded.
4| When saved, wave files will be converted to 8KHz, mono, 16 bit, PCM.
5| The internal flash memory can hold up to 28 seconds of recorded audio.

Note: Applications such as Sound Forge, Audacity, and Windows Sound Recorder can be used to create the WAV files.

  1.  Recording Emergency Announcements from a Phone
    Step 1.| Call into the VoIP Tower Phone with a Touch-Tone phone and access programming by entering the security code (845464 is the factory default).
    ---|---
    Step 2.| Enter 4, wait for the tone and then begin recording (28 seconds of record time is available).
    Step 3.| Enter # to stop the recording. Playback (for reviewing) is automatic.
    Step 4.| Enter
    5 to review the announcement again.
    Step 5.| If you choose to not use a voice announcement, enter *3 to clear the recording.

Example: “Hudson Elementary School, classroom number 216 needs assistance. Press the star (*) key on your telephone to hear this announcement again.”
VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG 14

  1. Relay Internal / External
    With the relay set to “Internal”, the VoIP Tower Phone will activate its onboard relay for door strike/gate control. The Relay should be set to “External” for higher security installations when using a Viking remote model RC-4A relay controller to activate the door strike / gate controller (see DOD 582). Factory Setting: Internal

  2. Relay Mode
    Door strike Mode. When programmed for Doorstrike Mode the relay will momentarily activate for the preprogrammed relay activation time after detecting the correct relay activation command (one or two digit touch tone) from the called party.
    Outbound Call Mode. When programmed for Outbound Call Mode the relay will activate continuously for the duration of any outbound call from the Emergency/Entry phone. This mode is useful for activating strobe lights for Emergency VoIP phones.
    Inbound/Outbound Call Mode. When programmed for Inbound/Outbound Call Mode the relay will activate continuously for the duration of any inbound or outbound call to or from the Emergency/Entry phone. This mode is useful for turning on IR flood lights, VoIP phones with cameras, etc.
    Doorbell Mode. When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call from the Emergency/Entry phone. This mode is useful for activating a door chime, etc. When activating door chimes, a 0.5 – 1 second relay activation time is recommended. LV-1K Control Mode. When programmed for LV-1K Control Mode the relay will activate continuously while the Emergency/Entry phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, activating LV-1K’s flashing LED and audible beep signals.
    Ring Mode. When programmed for Ring Mode the relay will continuously activate while the ringing extension is called. This mode is useful for activating a Viking model SL-2 strobe light, etc. Ring Flash Mode. When programmed for Ring Flash Mode the relay will momentarily turn on and off in a 400ms on/off cadence while the ringing extension is called. This mode is useful for activating a Viking LPL-1 Remote Visual Indicator, etc. Factory Setting: Door Strike

  3. Relay Activation Command
    The one or two-digit code stored in the Relay Activation Command is the touch tone command that the person being called must enter on their phone in order to momentarily activate the relay to control a door strike, mag-lock, gate controller, or another device. The code can contain the characters 0 – 9, # or Q. The code cannot match a relay latching command (Q1, Q0). The code must be entered while the remote phone is communicating with the Speakerphone. Factory Setting: QQ

  4. Relay Activation Time
    The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary touch tone command is entered. This number can range from 0.5 – 99 seconds. This also affects timing in Doorbell Mode. Factory Setting: 5 seconds

  5. Relay Buzz Volume
    The relay activation tone is a buzzing sound that is heard from the speaker when the door strike relay is activated. After the called party enters the correct relay activation command, the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound (relay activation tone) while the door strike relay is activated. The tone (buzz) length will match the relay activation time up to a maximum of 5 seconds. The tone (buzz) can be programmed to three different volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled. Factory Setting: 3

  6. Relay Latch Commands
    When set to “Enabled” the Remote Access Operation Commands (Q0 to Q1) to Un- Latch or Latch the relay are enabled. These can be entered on a Inbound call after the access code is dialed (if programmed). When set to “Disabled” the Remote Access Operation Commands (Q0 to Q1) to Un-Latch or Latch the relay are disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of inadvertently entering a latch command leaving a gate open/closed, etc. Factory Setting: Enabled

  7. Alternating Switch Action (Panic Button Mode)
    With Alternate Switch Action Enabled the CALL button alternately connects and disconnects calls. With Alternate Switch Action Disabled the CALL button connects calls only. Pressing the button again after the call has been initiated will not terminate the call. Factory Setting: Enabled

  8. Speaker Mode
    The Speaker Mode can be set to one of the following three modes. Factory Setting: ON OFF/Silent Monitoring Mode: In the “OFF” mode the speaker is disabled at all times. However, the speaker can be enabled after communication has been established by entering the touch tone command “9#”. The speaker will remain on for the duration of the call. ON (factory setting): In the “ON” mode the speaker is enabled during Inbound and Outbound calls. OFF Until Answered: In the “OFF Until Answered” mode the speaker will remain silent during dialing and will not turn on until the called party has answered.

  9. Speaker Volume
    The Speaker volume can be set from 0 – 9, 0 = lowest volume setting, 9 = highest volume setting. Adjusting this will set the volume level for incoming/outgoing Phone calls. Factory Setting: 3

  10. Ring Volume
    When set to Ring or Ring with AGC, The E-1600-IP Series Phone will output a loud ring when it is called. The level can be adjusted from 0 – 9. Factory Setting: 5

  11. Microphone Volume / Automatic Noise Cancelling Mode
    The microphone volume can be set from 1 – 9, 1 = lowest volume setting, 9 = highest volume setting. Alternatively, the microphone can be placed in the “Auto” Automatic Noise Cancelling mode. With the mic in Auto mode, when background noise increases, the mic gain will automatically decrease. When background noise decreases the mic gain will automatically increase. The Auto mode is useful in applications where the background noise level can change drastically. Factory Setting: 5

  12. Talk / Listen Delay (VOX)
    This feature selects switching time between talk and listens to modes (VOX switching time). The Talk/Listen Delay can be programmed from 0.1 – 0.9 seconds. Factory Setting: 0.5 seconds

  13. In-Band Audio Call Progress
    The In-Band Audio Call Progress Detection can be set to enable or disabled. In-Band Audio Call Progress detection should be enabled in applications where you are making an outbound call through your VoIP phone system and are relying on In-Band analog audio for ringback or busy detection. Factory Setting: Enabled.

  14. In-Band Audio Detect Sensitivity
    The In-Band Audio Detection level (Sensitivity) can be set from 1 – 9, 1 = minimum setting, 9 = highest setting. Increasing or decreasing the sensitivity may be required in applications where you are making an outbound call through your VoIP phone system and are relying on In-Band analog audio detection. Factory Setting: 5

  15. Repeat Announcement Option
    The VoIP Tower Phone can be programmed to play the announcement from 1 – 9 times or to continuously repeat the announcement every 6 seconds until a Touch Tone Q is detected from the distant party. The call-connected LED will turn on automatically after the announcement has stopped repeating. Factory Setting: 1 (play the announcement 1 time)

  16. Lap Counter
    With the lap counter disabled, if the VoIP Tower Phone is programmed to dial the next number on ring-no-answer and/or busy signal, the VoIP Tower Phone will continuously call its programmed phone numbers forever until the call is answered.
    The lap counter is a programmable counter that determines how many times the VoIP Tower Phone will cycle through its list of up to 5 Speed Dial phone numbers, before it stops the dialing process and hangs up. When all of the programmed phone numbers have been dialed, the lap counter is incremented and the dialing process repeats. When the lap counter has been met, the dialing process stops and the VoIP Tower Phone hangs up. Factory Setting: Disabled

  17. Call Length Timeout
    This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute up to a maximum of 9 minutes or disabled. With the call length disabled, the VoIP Tower Phone must rely on a call-ended signal, busy signal, Ring No Answer limit, or touch-tone # to hang- up. Factory Setting: 3 minutes

  18. Inbound Call Mode
    The Inbound Call Mode determines how the VoIP Tower Phone handles incoming SIP calls. One option is to generate a loud ring sound through the speaker. The VoIP Tower Phone can also auto answer a SIP call to transmit a page, control the relay or listen to transmit audio from the microphone. The last option is the silent monitor mode, which allows callers to listen to the transmit audio from the microphone. The “secure” options for auto answer require the callers to dial the access code in order to transmit a page, activate the relay or activate the optional RC-4A relays. Factory Setting: Auto Answer Disabled – Inbound SIP calls are not allowed.
    Auto Answer – Inbound SIP calls are auto answered on the first ring. This can also be used for Silent Monitoring by changing the Speaker Mode to ‘OFF/Silent Monitor”, See page 16. For more security use the Auto Answer Secure Mode.
    Auto Answer Secure – In the “Auto Answer – Secure” mode, the phone will automatically answer an incoming call on the first ring. The unit will then output 2 beeps but will not go into two-way voice mode. After the 2 beeps are heard, you will have 10 seconds to enter the pre-programmed 1-6 digit Access Code (see section 10 on page 14). When the correct code in entered, 2 beeps will be heard and the unit will enable the Two-Way Mode (mic and speaker audio). After the correct Access Code is entered, any of the “Remote Access Operation Commands” can be used (see Operation, section B on page 21). Note: If the wrong Access Code is entered or more than 10 seconds have elapsed, the phone will output 3 beeps and disconnect. Ring: In the “Ring” mode the speaker phone will not automatically answer an incoming call but will output a loud ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. There are four available ring cadences. Ring with AGC: In the “Ring with AGC” mode the speaker phone will not automatically answer an incoming call but will output a loud ring signal out of the speaker in a 2 seconds on, 4 seconds off ring pattern. The phone will automatically increase or decrease the ring volume based on background ambient noise. The call can then be answered by momentarily pressing the call button.

  19. Ring Cadence
    The Ring cadence can be programmed to one of 4 different cadences. Factory Setting: Normal Ring Normal Ring (single ring, 2 seconds on 4 seconds off) factory setting
    Double Ring (double ring, 1 second on 0.5 seconds off 1 second on 3.5 seconds off) Short-Short-Long (triple ring, 0.5 seconds on 0.5 seconds off 1 second on 3 seconds off) Short-Long-Short (triple ring, 0.5 seconds on 0.5 seconds off 1 second on 0.5 seconds off 0.5 seconds on 3 seconds off)

  20. Dial Next Number on Ring No Answer
    If enabled and a ring-no-answer is detected, the VoIP Tower Phone will dial the next programmed Speed Dial number after the programmed amount of rings. A momentary press of the call button will dial the first programmed Speed Dial number. Factory Setting: 7 (will redial after 7 rings)

  21. Dial Next Number on Busy
    If enabled and a busy is detected, the speakerphone will dial the next programmed Speed Dial number. A momentary press of the call button will dial the first programmed phone number. Factory Setting: Enabled

  22. Send ID Number as
    The I.D. number can be transmitted as RFC 2833 or as In-Band DTMF. Factory Setting: RFC 2833

  23. Call LED Mode
    The “Call” LED on the VoIP Tower Phone can be programmed to one of four different modes.
    Factory Setting: Entry Phone
    OFF Mode: Useful for silent monitoring applications. In this mode the LED will not light during normal operation. It will only light (blink) if it cannot register with the programmed SIP server or while manually resetting all network parameters to factory default.
    Entry Phone Mode: The LED will remain ON in the idle state, turn off while the button is pressed, blink during dialing, light steady when the call is answered, then turn OFF momentarily when the call is completed. Emergency Phone Mode: The LED will remain OFF in the idle state, blink during dialing, light steady when the call is connected, then turn OFF when the call is completed. Emergency Phone Outbound Only: On outbound calls, the LED will remain OFF in the idle state, blink during dialing, light steady when the call is connected, then turn OFF when the call is completed. On inbound calls, the LED will remain off. This is useful for silent monitoring on inbound calls.

  24. “Call” LED Control
    During outbound SIP calls the “CALL” LED can be programmed to light automatically when the called party has answered or only light after the called party has entered a touch-tone “Q”. Factory Setting: Automatic VIKING E 1600BLT2IPEWP VoIP Tower Phones - FIG15

  25. Mute Current / Next Alarm
    A network failure alarm will be indicated by providing 3 beeps every 30 seconds. A network failure indicates the unit is not registered to the SIP server or there is a communication failure with the gateway. The three beeps can be muted by clicking on “Mute Current / Next Alarm”. The Status LED will continue to flash to assist in troubleshooting. The alarm beeps can also be permanently disabled. See Permanent Alarm Mute.

  26. Permanent Alarm Mute
    Selecting “Alarm Tones Disabled” will mute all alarm tones indefinitely. To re-enable alarm tones select “Alarm Tones Enabled”. Factory Setting: Alarm Tones Enabled

  27. IP Firmware
    If new VoIP Tower Phone firmware is available, after opening the programming software a pop window will come up asking you if you would like to update firmware. An alternative method of updating can be done by clicking the IP firmware “Update IP” button. You can then browse to the folder that contains the PIP file for updating the unit’s IP firmware. This method is typically only used when Viking Technical Support has sent you updated IP firmware

  28. Unit Firmware
    If new VoIP Tower Phone firmware is available, after opening the programming software a pop up window will ask if you would like to update firmware. Another way to update is accomplished by clicking the Unit firmware “Update Unit” button. You can then browse to the folder that contains the HEX file for updating the unit’s firmware. This method is typically only used when Viking Technical Support has sent you updated firmware.

  29. Import / Export
    The Import / Export feature is useful for backing up all the VoIP Tower Phone’s programming or for importing programming when installing multiple units with a majority of the same programming.

  30. Clear Unit Settings
    Clicking on the “Clear Unit Settings” button in programming will reset all of the Programming Features back to their factory default settings. Note: This command will not change or reset your IP settings.

  31. Clear IP Settings
    Clicking on the “Clear IP Settings” will reset all of the IP settings back to their factory default settings. This also clears paging Group settings and Addresses. Note: This will not effect any speaker or paging settings.

  32. Diagnostics
    The Diagnostics section in the Viking IP Programming can be used to test the functionality of the mic, speaker and the onboard relay. Note: This will not work when relay mode is set to external or Alarm.

Operation

A. “HELP” Button
When the “HELP” button is pressed, the VoIP Tower Phone dials a pre-programmed telephone number. The Call Connected LED momentarily flashes during dialing. In the event the line is busy or there is a ring-no-answer, the unit can be programmed to call additional phone numbers.
The phone then cycles through up to 5 pre-programmed emergency numbers until the call is answered. When the call is answered, the digital voice announcer will automatically play to identify the location of the emergency call. The phones are factory programmed to play the announcement once, and then automatically light the “Call Connected” LED to show that handsfree communication to emergency personnel is established. The Q key will send the I.D. number (if programmed), and play the announcement again. The distant party will know the location of the emergency call by either the voice announcement or by decoding the touch tone I.D. number. Once the “Call Connected” LED is on, the # key can be used to force the phone to hang-up.
B. “INFO” Button (E-1600BLT2IPEWP)
When the “INFO” button is pressed (E-1600BLT2IPEWP only), the phone goes off- hook and dials the first “INFO” phone number programmed. If a busy signal is detected or the call goes unanswered, the phone will cycle through all five “INFO” phone numbers until the call is answered. When answered, handsfree communication is established. Note: The voice announcement is for Emergency/Help calls only and will not play on a call initiated from the “INFO” button.
C. Remote Access Operation Commands
The following commands can be entered after answering an inbound call from the emergency phone. The commands can also be entered on an outbound call to the emergency phone. After the emergency phone auto answers the call, two beeps will be heard. If the access code has been disabled, you can now enter the Remote Access Operation Commands below. If an Access code has been programmed, enter the Access code digits. With the correct code entered, two beeps will be heard and you can now enter the Remote Access Operation Commands below.

Feature Tone Tone Command Description
ActivateRelay QQ or Momentarily activate relay (1 or 2 digits,

factory set to QQ).
Un-Latch Relay| 0| Un-latch (deactivate) the relay.
Latch Relay| 1| Latch (continuously activate) the relay.
Disconnect| #| Disconnects or forces the emergency phone to hang up.
Send ID and Play Message| *| Send I.D. number (if programmed) and plays the announcement.

  • Note: Latching commands must be enabled (Q6) in programming.

Troubleshooting

If the unit cannot register with the programmed SIP server, the LED will blink on and off every two seconds, and three error beeps will be heard every 30 seconds until communication is restored. This alerts a potential user of a problem with the device that will prevent an emergency phone call from being made.
You may silence the error beeps, per instance, by pressing and holding the HELP button for 5 seconds or by clicking the “Mute Alarm Until Next Failure” button in the Viking VoIP Programming Software (see section B on page 9). The error beeps automatically re-enable once the unit is registered, to alert of any new problems that arise.

Related Products

ADA Compliant VoIP Emergency Phones with Built-In Dialer and Digital Voice Announcer
The 1600-IP Series ADA-Compliant VoIP Emergency Phones are designed to provide quick and reliable hands-free communication for SIP VoIP phone systems with PoE. All 1600-IP Series phones meet ADA requirements for elevator/ emergency telephones and can be programmed from any Touch Tone phone or PC on the same LAN. The phones can dial up to 5 programmable emergency numbers. In addition, the E-1600-20-IP, E-160022-IP, E-1600-52-IP and E-1600-TP2IPEWP feature a second “INFO” button that will dial up to 5 non-emergency numbers.
The 1600-IP Series phones can be programmed to automatically deliver a digital announcement to identify the location of the emergency call. Alternatively, a DTMF Touch Tone code may also be delivered. A “Call Connected” LED can be initiated manually or automatically. All programming parameters, including phone numbers and location numbers, are stored in non-volatile memory, requiring no batteries. All units are PoE-powered. For outdoor installations where the unit is exposed to precipitation or
condensation, select 1600-IP Series phones are available with Enhanced Weather Protection (EWP). EWP products feature foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards. For more information, see DOD 859.VIKING E
1600BLT2IPEWP VoIP Tower Phones - FIG20

Warranty

IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT VIKING TECHNICAL SUPPOAT RT:715-386-8666
Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better service, before you call please:

  1. Know the model number, the serial number and what software version you have (see serial label).
  2. Have the Product Manual in front of you.
  3. It is best if you are on site.

RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:

  1. The customer must contact Viking’s Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a
    a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.

  2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. The original product boxes are not designed for shipping – an overpack box is required to prevent damage in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to:
    VIKING ELECTRONICS 1531 INDUSTRIAL STREET HUDSON, WI 54016

  3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.

  4. RA number on carton: In large printing, write the RA number on the outside of each carton being returned.

RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):

  1. The customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
  2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer’s input and troubleshooting, a Return Authorization (RA) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
  3. After obtaining the RA number, return the approved equipment to your distributor. Please reference the RA number on the paperwork being shipped back with the unit(s), and also the outside of the shipping box. The original product boxes are not designed for shipping – an overpack box is required to prevent damage in transit. Once your distributor receives the package, they will replace the product over the counter at no charge. The distributor will then return the product to Viking using the same RA number.
  4. The distributor will NOT exchange this product without first obtaining the RA number from you. If you haven’t followed the steps listed in 1, 2 and 3, be aware that you will have to pay a restocking charge.

TWO-YEAR LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking’s Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number. This warranty does not cover any damage to the product due to lightning, over-voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO THE PURCHASER, OR ANY OTHER PARTY, FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD HEREUNDER. EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING’S OPTION, REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
If trouble is experienced with the E-1600-BLTIPEWP / E-1600BLT2IPEWP / E-1600-ASTIPEWP / E-1600AST2IPEWP phone, for repair or warranty information, please contact: Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 715-386-8666
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such tests in off-peak hours, such as early morning or late evenings.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
CANADA
This class A digital apparatus complies with Canadian ICES-003.
Product Support:715-386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

DOD 249
Printed in the U.S.A
ZF303710 REV E

Documents / Resources

| VIKING E-1600BLT2IPEWP VoIP Tower Phones [pdf] Instruction Manual
E-1600BLT2IPEWP, VoIP Tower Phones, E-1600BLT2IPEWP VoIP Tower Phones
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals