Maintenance and Safety:
IMPORTANT SAFETY INSTRUCTIONS – PLEASE DO NOT DISCARD THESE INSTRUCTIONS
READ THE INSTRUCTIONS COMPLETELY. FAILURE TO FOLLOW INSTALLATION INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, INJURY, OR DEATH. THE MANUFACTURER ASSUMES NO LIABILIY FOR CLAIMS RESULTING FROM THIS.
DANAGERS, WARNINGS, CAUTIONS, AND NOTICES ARE DEFINED PER ANSI Z535
DANGER: TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE AND TEST THAT POWER IS OFF BEFORE WIRING
WARNING: ELECTRIC SHOCK: NO OPERATOR SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED PERSONNEL
WARNING: VERIFY WITH LOCAL AUTHORITIES THAT THE LOCATION WHERE THE PEDESTAL IS
TO BE INSTALLED IS FREE FROM UNDERGROUND PIPLINES OR ELECTRICAL EQUIPMENT
WARNING: DO NOT USE THIS PRODUCT IF INPUT POWER WIRES IS FRAYED, BROKEN
INSULATION, OR ANY OTHER SIGNS OF DAMAGE
CAUTION: THE ELECTRICAL VEHICLE SUPPLY EQUIPMENT (EVSE) PEDESTAL MUST BE WIRED
PER THE NATIONAL ELECTRICAL CODE (NEC) AND LOCAL CODES
CAUTION: THE EVSE CHARGING STATION AND ELECTRICAL WIRING SHOULD BE INSTALLED
BY AN ELECTRICIAN IN ACCORDANCE WITH THE LOCAL ELECTRICAL CODES AND
REGULATIONS
CAUTION: GROUNDING: TO ENSURE THE SAFE OPERATION OF THE PEDESTAL, IT MUST BE
CONNECTED TO A GROUNDING CIRCUIT COMPLIANT WITH LOCAL BUILDING CODES
CAUTION: HANDLE PARTS WITH CARE. ALWAYS USE PROPER PERSONAL PROTECTIVE
EQUIPMENT (PPE) DURING THE INSTALLATION
RUN DEDICATED BRANCH CIRCUITS (ONE BREAKER PER EVSE CHARGING STATION), AS PER NEC 625 AND LOCAL BUILDING CODES
WHEN MOUNTING THE PEDESTAL IN PARKING SPACES OR PARKING GARAGES, APPROPRIATE ANTI- COLLISION PROTECTION MUST BE INSTALLED. REFERENCE LOCAL BUILDING CODES
TO ENSURE THAT THE EVSE CHARGING STATION AND PEDESTAL ARE INSTALLED PER AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS FOR ACCESSIBLE DESIGN GUDELINES, REFER TO CODE OF FEDERAL REGULATIONS DOCUMENT 28 CFR PART 36, SECTIONS 4.2 AND 4.4
IF YOU HAVE QUESTIONS ABOUT THE INSTALLATION, CONTACT EVOCHARGE TECHNICAL SUPPORT. IF YOU ARE UNSURE ABOUT A PROCEDUREDO NOT ATTEMPT TO PERFORM IT
THIS INSTALLATION INSTRUCTIONS SOLELY FOR THE PEDESTAL. DEPICTIONS OF THE EVOCHARGE EVSE ARE FOR REFERENCE ONLY. REFER TO THE EVOCHARGE EVSE INSTALLATION MANUAL INCLUDED WITH CHARGER UNIT OR AVAILABLE ON EVOCHARGE.COM
Technical Data and Specifications
Standards and Certifications:
Compliant with Americans with Disabilities Act (ADA) recommended charger
connect height of less than 48” and greater than 24”
Included Parts and Required Tools (Single charger install)
Required Tools (Not Included): T30 & T20 Torx Bit, 7/16” & 1/2″ Socket/Ratchet, and
Torque Wrench
Additional Parts Required (Not Included): EVSE, Stainless Steel Anchor Bolts,
Stainless Steel Hex Nuts and Washer, 1-inch x 90-Degree and Straight* Liquid
Tight Adaptor, 1-inch Flexible Liquid Tight, and Silicone Sealant
- Part is not referenced in this installation manual. Refer to EVSE installation manual.
Pedestal Installation
Anchor and Conductor Installation Wet Concrete:
The installer can use a prefabricated anchor included with the installation
kit offered by EvoCharge (EVC0901) or use stainless steel L or J type anchor
bolts with a diameter no greater than ½ inch. Reference Figure 2 for bolt
spacing.
The requirements below are the manufacturer’s minimum recommendations only. The location, dimensions, and composition of the concrete pad for supporting the pedestal should always comply with local building codes.
Use an electrical conduit of the appropriate size to bring the electrical cables to the center of the concrete anchors. Pull conductors from the service equipment to the pedestal installation site, leaving 5 feet of wire exposed. Reference Figure 3.
Hex nuts and washers are to be placed on the anchor bolts below the pedestal to adjust the vertical alignment, should the concrete pad not be level. A gap will be present between the concrete pad and pedestal base. Seal the gap with silicone sealant. Apply silicone per the manufacturer’s recommendations. Reference Figure 4.
Grounding: Verify grounding requirements with state, local, and national electrical codes and standards.
Pedestal Assembly:
Conduit and Liquid Tight Adaptors are sold separately in the installation kit (EVC9001). Insert the 90-degree Liquid Tight Adaptor into the access cover, as shown in Figure 7 (left). Tighten the locking nut to manufacture’s recommend torque value. When installing the thread forming screws, follow the sequence in Figure 9 and tighten all screws to 13 inch-pounds.
Fig. 6: Installation of Liquid Tight Adaptors and EVSE Cable Holster
Fig. 7: Access Cover Installation with Second EVSE
Installing Access Panel for Single EVSE Installation:
Fig. 8: Single EVSE Installation
Fig. 9: Order For Fastening Screws (Tighten to 13 inch-pounds)
Mounting EVSE:
Fig 10: Install Mounting Bracket (Tighten to 13 inch-pounds)
Fig 11: Slide the EVSE Onto the Mounting Bracket
Install Conduit:
Use the fabricated conduit included with the installation kit (EVC0901).
Otherwise, cut the Flexible Liquid Tight Conduit to the required length to
properly engage adaptors.