CISCO CW9166I-MR Meraki Ultra-High Performance Access Points Installation Guide
- June 8, 2024
- Cisco
Table of Contents
CW9166I-MR Meraki Ultra-High Performance Access Points
Installation Guide
CW9166I-MR Meraki Ultra-High Performance Access Points
Trademarks
Meraki, Meraki CW9166 I-MR, CW91641-MR, Meraki Cloud Controller, and Meraki
Mesh are trademarks of Cisco Systems, Inc. Other brand and product names are
registered trademarks or trademarks of their respective holders.
Statement of Conditions
In the interest of improving internal design, operational function, and/or
reliability, Cisco Systems reserves the right to make changes to the products
described in this document without notice. Cisco Systems does not assume any
liability that may occur due to the use or application of the product(s) or
circuit layout(s) described herein.
Warranty
Meraki, Inc. provides a lifetime warranty on this product. Warranty details
may be found at www.meraki.com/legal.
Scope of Document and Related Publications
The CW91661-MR,CW91641-MR Hardware Installation Guide describes the installation procedure for the CW91661-MR,CW9164I-MR indoor access point. Additional reference documents are available online at www.meraki.comilibrary/product.
CW91661-MR, CW91641-MR Overview
The Meraki CW91661-MR, CW91641-MR is an enterprise-class, dual-concurrent 4×4 MIMO 8o2max indoor access point designed for high-density deployments in offices, schools, hospitals and hotels. When connected to the Meraki Cloud Controller, the CW91661-MR, CW91641-MR enables the creation of ultra-high speed, reliable indoor wireless networks quickly, easily and cost- effectively.
2.1 Package Contents
The CW91661-MR, CW91641-MR package contains the following:
- CW91661-MR,
- CW91641-MR access point
- Mountingplate
- Drop ceiling mounting kit
- Wall screws
- Security screws
- Mounting Template
2.2 UnderstandingtheCW91661-MR, CW91641-MR
CW9166 I-M R, CW91641-M R Operation Temperature: 32° F to 122° F (o °C to
5o ° C)
Your Meraki CW91661-MR, CW91641-MR has the followingfeatures:
- Kensington lock hard point
- Mount plate attachment slots (2x)
- Cable access bay
- Desk mount feet (4x) with M4*5mm pan-head screws
- CW91661-MR, CW91641-MR cable access bay
- Factory Reset Button
- Ethernet port Power supplied by PoE: 42.5-57Vdc, o.847-o.631A or 42.5-57Vdc, 0.776-0.579A
- AC Adapter plug (sold separately) Power supplied by adapter 54Vdc, o.92A
Your CW91661-MR, CW91641-MR mount plate has the following features:
- Access point mounting posts (2x)
- Various mounting holes
2.3 Security Features
The CW91661-MR, CW91641-MR features multiple options for physically securing
the access point after installation:
- Security screw — The accessory kit includes screws that can be used to secure the access point to the mount plate. Engaging the security screw prevents accidental dislodging and theft.
- Kensington lock — The access point contains a hard point that allows it to be secured to any nearby permanent structure using a standard Kensington lock.
2.4 Ethernet Ports
The CW91661-MR, CW91641-MR features an Ethernet RJ45 port that accepts 8o2.3af
power (labeled “PoE”). This port should be used for uplink to your WAN
connection.
2.5 Power Source Options
The CW91661-MR, CW91641-MR access point can be powered using either the Meraki
AC Adapter or 8o2.3af PoE Injector (both sold separately) or a third-party
8o2.3af PoE switch.
2.6 Factory Reset Button
If the button is pressed and held for at least five seconds and then released,
the CW91661-MR, CW91641- M R will reboot and be restored to its original
factory settings by deleting all configuration information stored on the unit.
Pre-Install Preparation
You should complete the following steps before going on-site to perform an
installation.
3.1 Configure Your Network in Dashboard
The following is a brief overview only of the steps required to add an
CW91661-MR, CW91641-MR to your network. For detailed instructions about
creating, configuring and managing Meraki wireless networks, refer to the
Meraki Cloud Controller Manual
(meraki.comilibrary/product).
- Login to http://dashboard.meraki.com. If this is your first time, create a new account.
- Find the network to which you plan to add your APs or create a new network.
- Add your APs to your network. You will need your Meraki order number (found on your invoice if you ordered directly from Meraki) or the serial number of each AP, which looks like Qxxx-xxxx-xxxx, and is found on the bottom of the unit. You will also need your Enterprise Cloud Controller license key, which you should have received via email from shipping@meraki.com.
- Go to the map/floor plan view and place each AP on the map by clicking and dragging it to the location where you plan to mount it.
3.2 Check and Upgrade Firmware
To ensure your CW91661-MR, CW91641-MR performs optimally immediately following
installation, Meraki recommends that you facilitate a firmware upgrade prior
to mounting your CW91661-MR, CW91641-MR.
- Attach your CW91661-MR, CW91641-MR to power and a wired Internet connection. See p.19 of this Hardware Installation Guide for details.
- The CW91661-MR, CW91641-MR will turn on and the Power LED will glow solid orange. If the unit does not require a firmware upgrade, the Power LED will turn white within thirty seconds.
- If the unit requires an upgrade, the Power LED will begin blinking orange until the upgrade is complete, at which point the Power LED will turn solid white. You should allow about an hour for the firmware upgrade to complete, depending on the speed of your intemet connection.
3.3 Check and Configure Firewall Settings
If a firewall is in place, it must allow outgoing connections on particular ports to particular IP addresses. The most current list of outbound ports and IP addresses can be found here: http://tinyurl.com/y79une3
3.4 Assigning IP Addresses to CW91661-MR, CW91641-M Rs
All gateway CW91661-MR, CW9164I-MRs (CW91661-MR, CW9164I-M Rs with Ethernet
connections to the LAN) must be assigned routable I P addresses. These IP
addresses can be dynamically assigned via DHCP or statically assigned.
3.4. I Dynamic Assignment
When using DHCP, the DHCP server should be configured to assign a static IP
address for each MAC address belonging to a Meraki AP. Other features of the
wireless network such as 8o2.tx authentication, may rely on the property that
the APs have static IP addresses.
3.4.2 Static Assignment
Static I Ps are assigned using the local web server on each AP. The following
procedure describes how to set the static IP:
-
Using a client machine (e.g. a laptop), connect to the AP either wirelessly (by associating to any SSID broadcast by the AP) or over a wired connection.
If using a wired connection, connect the client machine to the CW91661-MR, CW91641-MR either through a PoE switch or a Meraki PoE Injector. If using a PoE switch, plug an Ethernet cable into the CW91661-MR, CW91641-MR’s Ethernet jack, and the other end into a PoE switch. Then connect the client machine over Ethernet cable to the PoE switch. If using a Meraki PoE Injector, connect the CW91661-MR, CW91641-MR to the “PoE” port of the Injector, and the client machine to the “LAN” port. -
Using a web browser on the client machine, access the AP’s built-in web server by browsing to http://my.meraki.com. Alternatively, browse to http://lo.128.128.128.
-
Click on the “Static I P Configuration” tab. Log in. The default user name is “admin”. The default password is the AP’s serial number, with hyphens included
-
Configure the static IP address, net mask, gateway IP address and DNS servers that this AP will use on its wired connection. 5. If necessary, reconnect the AP to the LAN.
3.4.3 Static IP via DHCP Reservations
Instead of associating to each Meraki AP individually to configure static IP
addresses, an administrator can assign static IP addresses on the upstream
DHCP server. Through “DHCP reservations”, I P addresses are “reserved” for the
MAC addresses of the Meraki APs. Please consult the documentation for the DHCP
server to configure DHCP reservations.
3.5 Collect Tools
You will need the following tools to perform an installation:
3.6 Collect Additional Hardware for Installation
Installation Instructions
4.1 Choose Your Mounting Location
A good mounting location is important to getting the best performance out of
your CW91661-MR, ONgi641-MR access point. Keepthe following in mind:
- The device should have unobstructed line of sight to most coverage areas. For example, if installing in an office filled with workspaces divided by mid-height cubicle walls, installing on the ceiling orhigh on a wall would be ideal.
- Power over Ethernet supports a maximum cable length of 30o ft ciao m).
- If being used in a mesh deployment, the CW91661-MR, CW91641-M R should have line of sight to at least two other Meraki devices. For more detailed instructions regarding access point location selection, reference the Meraki Network Design Guide (meraki.com/library/product).
4.2 Install the CW91661-MR, CW9i641-MR
For most mounting scenarios, the CW91661-MR, CW91641-MR mount plate provides a
quick, simple, and flexible means of mounting your device. The installation
should be done in two steps. First, install the mount plate to your selected
location. Then, attach the CW91661-MR, CW91641-MR to the mount plate.
!!! This equipment is only suitable for mounting at heights s 2 m !!!
4.2.1 Attach the Mount Plate
The CW9166 I-M R, CW91641-MR mount plate can be used to install your access
point in a wide range of scenarios: wall or solid ceiling, below a drop
ceiling, on various electrical junction boxes, or above a drop ceiling (in the
plenum).
The mount plate contains a variety of hole patterns that are customized for
each installation scenario. The mounting template (included inbox with mount
plate) should be used to drill holes for wall mounts and also to identify the
correct hole patterns in the mount plate that should be used for each type of
mount.
The following images also show the hole patterns that should be used for each
type of mount:
4.2.1.1 Wall or Solid Ceiling Mount Using Mount Plate
Using included screws, attach the mount plate to your mounting wall or
ceiling.
It is recommended that the CW91661-MR, CW91641-MR be mounted to a wall or
solid ceiling using the mount plate for physical security reasons.
If mounting your CW91661-MR to a wall, skip to “Power the CW91661-MR” on P. 20
4.2.1.2 Electrical Junction Box Mount Using Mount Plate
The CW91661-MR, CW91641-MR can be mounted to a 4″ square cable junction box, a
3.5 or 4″ round cable junction box, or various U.S. and European outlet boxes
(mounting screws are not included).
Using appropriate mounting hardware for your specific type of junction box,
attach the mount
4.2.2 Powerthe CW91661-MR, CW91641-MR
If mounting to an electrical junction box, feed the Ethernet cable through
the cable access hole in the Mount Plate.
If mounting to a wall or ceiling, the Ethernet cable will feed through the
cable slot on bottom of the CW91661- MR, CW91641-MR.
4.2.2.1 Powering the CW91661-MR, CW91641-MR with the Meraki AC Adapter
(sold separately)
- Plug the power cord into the CWgi661-MR, CW91641-MR and the other end into a wall outlet.
- Plug an Ethernet cable that is connected to an active Ethernet connection into the Etho port on the CW91661-MR, CW91641-MR.
4.2.2.2 Poweringthe M.410-IVIR with the Meraki 8o2.3at Powerover Ethernet Injector(sold separately)
- Plug the power cord into the PoE Injector and the other end into wall power.
- Plug an Ethernet cable that is connected to an active Ethernet connection into the “IN” port on the injector.
- Route Ethernet cable from the “OUT” port on the injector to the Etho port in the cable bay of the CW91661-MR, CW91641-MR.
4.2.2.3 Powering the CW9166I-MR, CW91641-MR with an 8o2.3at Power over
Ethernet Switch Route Ethernet cable from a port on an active 8o2.3at PoE
switch to the Etho port in the bay of the CW91661-M R, CW91641-M R.
The CW91661-MR is Gigabit Ethernet-capable. To maximize device performance, a
■ Gigabit-capable switch should be used.
4.2.3 MounttheCW91661-MR, CW91641-MR
4.2.3.2 Assemble CW9166 l-M R, CW91641-M R to the Mount Plate
(This section applies to wall and/or solid ceiling, drop ceiling or electrical
junction box mount where you have already installed the mount plate.)
Insert the top latch on the mount plate into the top mount plate attachment
slots on the back of the device. Rotate the bottom of the unit into the bottom
mount plate attachment slot. The unit will click into place.
4.2.3.3 Desk or Shelf Mount
The CW91661-MR, CW91641-MR can be placed on a desk or shelf resting on the
non-scratch rubber feet. The mount plate is not necessary for a desk or shelf
mounting.
4.3 Secure the CW91661-MR, CW91641-MR
Depending on your mounting environment, you may want to secure the CW91661-MR,
CW91641-MR to its mount location. Your CW91661-MR, CW91641-MR can be secured
in several ways. If the CW91661-MR, CW91641-MR has been installed using the
mount plate, it can be secured via security screw (Torx and Philips head
security screws are included; choose one), and/or Kensington lock. If the
mount plate was not used, the CW91661-MR, CW91641-MR can still be secured
using a Kensington lock.
4.3.1 Security Screw
Install the security screw in the lower mount plate tab.
4.3.2 Kensington Lock
Attach a Kensington lock cable to the access point at the hard point on the
side of the device. Attach the other end of the cable to a secure location,
such as a pipe or building fixture.
4.4 Verify Device Functionality and Test Network Coverage
- Check LEDs The LED should be solid white. If it is flashing orange, the firmware is automatically upgrading and the LED should turn green when the upgrade is completed (normally in under thirty minutes). Note: Your CW91 66I-MR, CW9164 I-M R must have an active route to the Internet to check and upgrade its firmware.
- Verify access point connectivity Use any 802.11 client device to conned to the CW91661-MR, CW91641-MR and verify proper connectivity using the client’s web browser.
- Check network coverage Confirm that you have good signal strength throughout your coverage area. You can use the signal strength meter on a laptop, smart phone, or other wireless device.
Troubleshooting
Reference the Meraki knowledge base at http://meraki.com/support/knowledge_base for additional information and troubleshooting tips.
Regulatory
FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
- This de-vice may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to correct the interference by one of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution
Any changes or modifications no expressly approved by Meraki could void the
user’s authority to operate this equipment. This Transmitter must not be co-
located or operation in conjunction with any other antenna or transmitter.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 41 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
IEEE 802.11b or 8o2.11g operation of this product in the USA is firmware-
limited to channels 1 through 11.
FCC regulations restrict the operation of this device to indoor use only. The
operation of this device is prohibited on oil platforms, cars, trains, boats,
and aircraft, except that operation of this device is permitted in large
aircraft while flying above 10,000 feet. Operation of transmitters in the
5.925-7.125 GHz band is prohibited for control of or Communications with
unmanned aircraft systems.
Professional installation is required
If the device is going to be operated in the 5.15 – 5.25 G H z frequency
range, then it is restricted to indoor environment only. This device meets all
other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
Industry Canada Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
Industry Canada Caution
(i) the device for operation in the band 5150-5250 MHz is only for indoor use
to reduce the potential for harmful interference to co-channel mobile
satellite systems;
Industry Canada Radiation Exposure Statement
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 27 cm between the radiator & your body.
Co-location Statement
The transmitter module may not be co-located with any other transmitter or
antenna.
The Country Code Selection feature is disabled for products marketed in the
US/Canada.
For product available in the USA/Canada market, only channel 1-1i can be
operated. Selection of other channels is not possible.
This equipment complies with EU radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance zocm between the radiator & your body.
Operation shall be limited to indoor use only.
Operation on oil platforms, cars, trains, boats and aircraft shall be
prohibited except for on large aircraft flying above 10,000 ft.
EU & UK
The frequency and the maximum transmitted power in EU are listed below:
2412-2472MHz:XX.XX dBm
2402-2480M Hz (BRJEDR): XX.XX dBm
2402-248oM Hz (LE): XX.XX dBm
3180-324oM Hz: XX.XX dBm
3260-332oM Hz: XX.XX dBm
3300-3700: XX.XX dBm
5745-3823MHz: XX.XX dBm
5945-6423MHz: XX.XX dBm
The device is restricted to indoor use only when operating in the 5150 to 535o
MHz frequency range.
CE: The device is restricted to indoor use only when operating in the
5945 to 6423MHz frequency range.
| AT| BE| BG| HR| CH| CY| CZ
---|---|---|---|---|---|---|---
DE| DK| EE| Fl| FR| EL| HU
IE| IS| IT| LI| LV| LT| LU
MT| NL| NO| PL| PT| RO| SK
TR| SI| ES| SE| UK(NI)| |
UK: The device is restricted to indoor use only when operating in the 5925 to 6423MHz frequency range.
| UK
---|---
Hereby, Cisco Systems Inc. declares that the radio equipment type CW91661 series is in compliance with Directive 2014/33/EU. The full text of the EU declaration of onformity is available at the following internet address: https://meraki.cisco.com/compliance/?sortby=most-recent
Copyright © 2020 Cisco Systems, Inc.
All rights reserved. Trademarks
www.ciscosystems.com
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134 USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>