Yale Locks & Hardware Yale Real Living Assure Lock Interconnected YRC620-ZW2 Manual

June 8, 2024
Yale Locks & Hardware

Yale

Yale Real Living Assure Lock Interconnected

SKU: YRC620-ZW2

Quickstart

This is a
secure
Door Lock – Keypad
for
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Yale Real Living Assure Lock Interconnected combines electronic deadbolts with the convenience of a passage lever for panic proof egress. From the inside, both the latchbolt and the deadbolt are retracted simultaneously in a single motion for a quick and easy exit. This lock works with Z-Wave technology and also comes in 12 finishes.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Silent Mode on/off

Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent. Default is 1 or High Volume
Size: 1 Byte, Default Value: 1

SettingDescription

1 – 3 Sound level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

SettingDescription

-128 One Touch Locking On
0 One Touch Locking Off

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Privacy Button On
0 Privacy Button Off
0 Normal Mode
1 Vacation Mode
2 Privacy Mode

Parameter 13: Lock Status LED

0x00 = OFF , 0xFF=ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Lock Status LED On
0 Lock Status LED Off

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.No default value
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Reset to Factory ON
0 Reset to Factory Off

Parameter 16: Escape Return Mode

0x00 = OFF, 0xFF = ON default is 0x00 or OFFEnables the Escape Return mode of operation for the lock.
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Escape Return ON
0 Escape Return OFF

Parameter 2: Auto Relock on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Auto Relock On
0 Auto Relock OFF

Parameter 21: Eco Mode on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode of operation with reduced sound and led brightness.
Size: 1 Byte, Default Value: 0

SettingDescription

-128 Eco Mode ON
0 Eco Mode OFF

Parameter 3: Relock Time

10 to 180 seconds default is 30 seconds
Size: 1 Byte, Default Value: 30

SettingDescription

10 – 180 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

SettingDescription

3 – 10 Times

Parameter 5: Language

1=English, 2=Spanish, 3=French default is 1= English
Size: 1 Byte, Default Value: 1

SettingDescription

1 English
2 Spanish
3 French

Parameter 7: Shut Down Time (After wrong codes)

10 to 180 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

SettingDescription

10 – 180 Seconds

Parameter 8: Operating Mode

00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work
Size: 1 Byte, Default Value: 0

SettingDescription

0 Normal mode
1 Vacation mode
2 Privacy mode

Technical Data

Hardware Platform ZM5101
Device Type Door Lock – Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.78:24.00
Z-Wave Version 6.51.07
Certification ID ZC10-19066557
Z-Wave Product Id 0x0129.0x800E.0x1200
Outdoor Use ok
Supported Notification Types Access Control
IP (Ingress Protection) Rated ok
Firmware Updatable Updatable by Consumer by RF
Sensors Open/Closed (Binary)
Door Lock Type Deadbolt Motor Attachment
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Door Lock Logging
  • Door Lock V2
  • Firmware Update Md V3
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Schedule Entry Lock V3
  • Security
  • Time Parameters
  • Time V2
  • User Code
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Yale Locks & Hardware User Manuals

Related Manuals