Yale Locks & Hardware nexTouch Push Button Lever Lock NTB612-ZW2 Manual
- June 8, 2024
- Yale Locks & Hardware
Table of Contents
- Yale
- nexTouch Push Button Lever Lock
- SKU: NTB612-ZW2
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Silent Mode on/off
- Parameter 11: One Touch Locking
- Parameter 12: Privacy Button
- Parameter 15: Reset to Factory Defaults
- Parameter 18: Door Propped Timer
- Parameter 19: DPS Alarm
- Parameter 2: Auto Relock On/Off
- Parameter 21: Eco Mode On/Off
- Parameter 3: Auto Relock Time
- Parameter 4: Wrong Code Entry Limit
- Parameter 5: Language
- Parameter 7: Shut Down Time (after wrong code entries)
- Parameter 8: Operating Mode
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Yale
nexTouch Push Button Lever Lock
SKU: NTB612-ZW2
Quickstart
This is a
secure
Door Lock – Keypad
for
.
Please make sure the internal battery is fully charged.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Unlock whats next in security with nexTouch commercial keypad door locks from Yale. The nexTouch keyless electronic door lock combines a modern look with durability that is perfect for your multi-family property, small business office space, retail space, hotel, airport, restroom, or mixed-use commercial building. All nexTouch Locks are easy to use and install, and allow you to manage access with up to 500 unique PIN codes. The nexTouch is ANSI/BHMA Grade 1 Certified and weather resistant.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | Z-Wave Plus Lifeline |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Silent Mode on/off
Level control, 1 = High Volume, 2 = Low Volume, 3 = Silent.Default is 2 or
Low Volume
Size: 1 Byte, Default Value: 2
SettingDescription
1 – 3 | Level |
---|
Parameter 11: One Touch Locking
0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0
SettingDescription
255 | One Touch Locking On |
---|---|
0 | One Touch Locking Off |
Parameter 12: Privacy Button
0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0
SettingDescription
255 | Privacy Button On |
---|---|
0 | Privacy Button Off |
Parameter 15: Reset to Factory Defaults
01 = Lock will execute Reset To Factory.No default value
Size: 1 Byte, Default Value: 0
SettingDescription
255 | Reset to Factory On |
---|---|
0 | Reset to Factory Off |
Parameter 18: Door Propped Timer
10 to 2540 second. This value is represented as seconds X 10.(ie a value of
4 would mean a door propped timer of 40seconds) Set to 0x00 to disable Door
Propped Alarm. Default= 0x00 (off)
Size: 1 Byte, Default Value: 0
SettingDescription
10 – 255 | Seconds |
---|
Parameter 19: DPS Alarm
0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door
condition alarms for locks thatsupport a door position sensor. Any lock that
does notsupport DPS will always report 0x00.
Size: 1 Byte, Default Value: 0
SettingDescription
255 | DPS Alarm On |
---|---|
0 | DPS Alarm Off |
Parameter 2: Auto Relock On/Off
0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0
SettingDescription
255 | Auto Relock On |
---|---|
0 | Auto Relock Off |
Parameter 21: Eco Mode On/Off
0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to
lower power mode of operationwith reduced sound and led brightness.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Eco Mode Off |
---|---|
127 | Eco Mode On |
Parameter 3: Auto Relock Time
10 to 180 seconds default is 30 seconds
Size: 1 Byte, Default Value: 30
SettingDescription
10 – 180 | Seconds |
---|
Parameter 4: Wrong Code Entry Limit
3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5
SettingDescription
3 – 10 | Times |
---|
Parameter 5: Language
1=English, 2=Spanish, 3=French default is 1= English
Size: 1 Byte, Default Value: 1
SettingDescription
1 | English Language |
---|---|
2 | Spanish Language |
3 | French Language |
Parameter 7: Shut Down Time (after wrong code entries)
10 to 180 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60
SettingDescription
10 – 180 | Seconds |
---|
Parameter 8: Operating Mode
00 = normal mode (this is the default mode)01 = vacation mode, keypad
lockout02= privacy mode, no keypad. RF Unlock will work
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Normal Mode (Default) |
---|---|
1 | Vacation Mode (Keypad Locked Out) |
2 | Privacy Mode (Keypad Locked, RF Unlock Functional) |
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Door Lock – Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 255 FW: 1.78:32.33 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-22067110 |
Z-Wave Product Id | 0x0129.0x8101.0x0B0C |
Color | Antique Brass |
IP (Ingress Protection) Rated | ok |
Outdoor Use | ok |
Door Lock Type | Deadbolt |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Door Lock Logging
- Door Lock V2
- Firmware Update Md V3
- Manufacturer Specific V2
- Notification V4
- Powerlevel
- Schedule Entry Lock V3
- Security
- Time Parameters
- Time V2
- User Code
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.