KPL PIR-Z-Wave IX32-Z-Wave Manual PIR-Z-Wave

October 28, 2023
KPL

KPL

PIR-Z-Wave

SKU: IX32-Z-Wave

Quickstart

This is a ****

Alarm Sensor
for
U.S. / Canada / Mexico
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The Z-Wave sensor is equipped with Z-Wave500 series main control chip. It is a passive infrared intrusion sensor that adopts Energy Integration Logical Processing, Random Dynamic Time Segmentation & Digital Signal Processing Technologies. With precise columnar Fresnel lens, it can increase its energy receiving efficiency and sensitivity without false alarm. In conjunction with advanced software technology, it will make an accurate judgement between real intruder & interference factors that may cause false alarm. Superior ability to detect & prevent false positives. The pulse number is optional, suitable for kinds of residential constructions, preventing false positive & false negative that other ordinary indoor sensors cannot do. Its performance is far beyond other ordinary PIR alarms. Besides, we use large capacity built-in battery & special power saving solution, battery working life is up to 3 years.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 1| It will send NOTIFICATION_REPORTto the device in Lifeline group when the PIR sensor is triggered/ recovered , tamper switch is triggered / recovered. When in low battery status, PIR sensor will send BATTERY_REPORT to Lifeline group device periodically.The PIR sensor will send. DEVICE_RESET_LOCALLY_NOTIFICATION to Lifeline group device when the device recovers to factory settings.
---|---|---
2| 2| When the PIR sensor is triggered, it will send BASIC SET command to control these devices in Group2.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Basic Set

If there is any device under Association Group2, the PIR sensor will send Basic Set = value command to control that device when the PIR sensor is alarm.
Size: 1 Byte, Default Value: 255

SettingDescription

1 – 100| Decimalism 1-100,Used for quantitative control of other z-wave devices, like adjusting the brightness of lights.
---|---
255| Decimalism 255,To control other devices that only receive basic set value = 0xff.

Parameter 2: Turn Off Light Time Configuration

If there is any device under Association Group2, the PIR sensor will send Basic Set = value command to Group2, and send Basic Set = 0x00 command to turn-off light after 5 x t seconds.
Size: 1 Byte, Default Value: 4

SettingDescription

1 – 24| Decimalism 1-24,To control the time to turn off the lights.The basic step value of time is 5 seconds.If the value is set to 4,start timing when the lights are turned on,turn off the lights after 4*5 seconds =20 seconds
---|---

Parameter 3: PIR Sensor Alarm Elimination Time Configuration

Min set time is 5s. If the configuration is 1, that means it will eliminate alarm after 5 seconds, if t, will eliminate alarm after 5 x t seconds.
Size: 1 Byte, Default Value: 4

SettingDescription

1 – 24| Decimalism 1-24,Used to set to send the eliminate alarm time after PIR alarm.The basic step value of time is 5 seconds,If the value is set to 4,send the eliminate alarm message after alarm 4 * 5 seconds = 20 seconds
---|---

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 5.36
Z-Wave Version 6.51.09
Certification ID ZC10-19076690
Z-Wave Product Id 0x0214.0x0005.0x0003
Supported Notification Types Home Security
Sensors Motion/No Motion (Binary)
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Sensor Binary V2
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)