HILTI KB-TZ2 SS304 Kwik Bolt TZ2 Wedge Anchor Instruction Manual
- June 8, 2024
- HILTI
Table of Contents
HILTI KB-TZ2 SS304 Kwik Bolt TZ2 Wedge Anchor
Operating Instructions
|
Anchor Diameter [inch]
---|---
Symbol| Setting Information| Units| ¼| ⅜| ½|
⅝| ¾| 1
| Hollow Drill Bit| –| –| –| ✔| ✔| ✔| ✔
| Dust Removal Systems| –| ✔| ✔| ✔| ✔| ✔| ✔
AT-System
| Adaptive Torque System**| –| –| ✔| ✔| ✔| –| –
| Diamond Core Bit| –| –| ✔| ✔| ✔| ✔| –
| Drill Bit Diameter| [inch]| ¼| ⅜| ½| ⅝| ¾| –
| Effective Embedment Depth| [inch]| 1½| 1½| 2| 2½| 2| 2½| 3¼| 2¾| 3¼| 4| 3¼|
3¾| 4¾| 4| 5¾
| Nominal Embedment Depth| [inch]| 1¾| 1⅞| 2½| 3| 2½| 3| 3¾| 3¼| 3¾| 4½| 4|
4½| 5½| 4⅝| 6⅜
| Minimum Hole Depth in Base Material| [inch]| 2| 2| 2¾| 3¼| 2¾| 3¼| 4¼| 3¾|
4¼| 4¾| 4¼| 4¾| 5¾| 5| 6¾
| Installation Torque
Concrete
| carbon steel| [ft-lb]| 4| 30| 50| 40| 110| 185
SS304, SS316| [ft-lb]| 6| 30| 40| 60| 125| 185
| Installation Torque
Grout-Filled CMU
| carbon steel| [ft-lb]| 4| 15| 25| 30| 50| –
SS304, SS316| [ft-lb]| 6| 15| 25| 35| 50| –
| Fixture Hole Diameter| [inch]| 5⁄16| 7⁄16| 9⁄16| 11⁄16| 13⁄16| 1⅛
WS
| Wrench Size| [inch]| 7⁄16| 9⁄16| ¾| 15⁄16| 1⅛| 1½
Use only carbide-tipped masonry drill bits complying with ANSI B212.15.1994
* For steps 1a or 1b, make sure to drill deep enough to achieve h0,
taking into account the depth of debris remaining in the hole.
** AT-System not applicable for grout-filled CMU and wood fastening
applications.
For UL Listing, the ⅝” anchor is rated up to 10 NPS at a minimum of 3-¼”
nominal embedment. UL Listing does not cover the ¼” and 1″ anchor sizes.