BENETEK Smart Hidden Door Lock with Deadbolt BSL01 Manual
- June 8, 2024
- BENETEK
Table of Contents
- BENETEK
- Smart Hidden Door Lock with Deadbolt
- SKU: BSL01
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BENETEK
Smart Hidden Door Lock with Deadbolt
SKU: BSL01
Quickstart
This is a
secure
Door Lock – Keypad
for
CEPT (Europe).
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
- Ensure the SHDL is powered and the battery is fully charged.2) Set the main controller into the Add device mode (see a main controllers operating manual).3) Triple click Z-Wave button on the Z-Wave module(inside lock body) within 1.5 seconds, the LED will flicker rapidly while inclusion process implement and light on 2 second after processing complete.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
BENETEK smart lock is night lock style with dead bolt, remote, key, RF card, keypad, Z-Wave.Material: The lock was made of zinc alloy. The lock shell is 4mm thick. And the inside structure was made of metal. 304 stainless steel panel, the thickness of 1.5mmWeight:1800g, Power supply method: Four AA alkaline batteries and one 18650 rechargeable backup battery.Batteries lifetime: 2 groups of batteries, Rechargeable battery, Alkaline Batteries: Approximate 1 Year battery life (depend on the usage of the lock)Features of the Latch: Lock Latch length > 25mm, Comply with GA/T73-94 5.16B standard. Latch size: 25x30x15mm, it is even stronger!Low battery indicator: Prompt indicator in low pressure and It will unlock automatically when no electricity(optional)Urgent method:Mechanical damage to unlock(It has mounting hole on the lock for mechanical lock) Working environment:-30~70 Humidity<90% Working current (MAX): <500mAStatic current of battery:<95A Wireless remote distance:10m (Depend on environment)Z-Wave distance(to Z-Wave server): 30m indoorAppearance size: Lock body 152x80x40(mm) Panel: 125x50x25(mm)Voltage of entrance guard: DC 6V~30VVoltage of urgent power supply: DC 5V~6.5V (Optional)Capacity of remote: 25pcs Can expandCapacity of password: 13 setscapacity of card: 104pcs can expandZ-Wave frequency:868.4 MHz – China/Europe, 908.4 MHz – USA, 921.4 MHzAustralia/New Zealand, 869.2 MHz – Russia
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Smart Hidden Door Lock restores factory default automatically when the device is excluded.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
- Ensure the SHDL is powered and the battery is fully charged.2) Set the main controller into the Add device mode (see a main controllers operating manual).3) Triple click Z-Wave button on the Z-Wave module(inside lock body) within 1.5 seconds, the LED will flicker rapidly while inclusion process implement and light on 2 second after processing complete.
Exclusion
- Ensure the SHDL is powered and the battery is fully charged.2) Set the main controller into the Remove device mode (see a main controllers operating manual).3) Triple click Z-Wave button on the Z-Wave module(inside lock body) within 1.5 seconds, the LED will flicker rapidly while exclusion process implement and light on 2 second after processing complete.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| Association Group 1 is assigned to sending SHDL lifeline status to
associated devices, including send Door Lock Operation report frame while SHDL
unlocked and locked, send Battery level report frame while batterylevel is
change.
---|---|---
2| 1| Association Group 2 is assigned to sending the Basic Set Off frame to
associated device (e.g. another SHDL) while the SHDL is unlocked and sending
the Basic Set On frame to associated device while the SHDL is locked with
security transport if SHDL was added to network as security node or with non-
security transport if SHDL was added to network as non-security node.
3| 1| Association Group 3 is assigned to sending the Basic Set On frame to
associated devices with non-security transport while the SHDL is unlocked.
4| 1| Association Group 4 is assigned to sending the Basic Set Off frame to
associated devices with non-security transport while the SHDL is locked.
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Door Lock – Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 33 FW: 1.01 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17115834 |
Z-Wave Product Id | 0x032D.0x3002.0x0006 |
Color | Bronze |
Door Lock Type | Deadbolt Motor Attachment |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Application Status
- Association Grp Info
- Association V2
- Basic
- Battery
- Device Reset Locally
- Door Lock V2
- Manufacturer Specific V2
- Powerlevel
- Security
- Version V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>