Hank Smart Plug HKZW-SO01 Manual
- June 8, 2024
- HANK
Table of Contents
- Hank
- Smart Plug
- SKU: HKZW-SO01
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 151: Threshold of change in wattage
- Parameter 152: Threshold of change in wattage percentage
- Parameter 171: Intervals of sending METER REPORT (for wattage)
- Parameter 172: Intervals of sending METER REPORT (for kWh)
- Parameter 173: Intervals of sending METER REPORT (for voltage).
- Parameter 174: Intervals of sending METER REPORT (for current).
- Parameter 20: Overcurrent protection
- Parameter 21: Setting Smart Plugs load status after re-power on
- Parameter 24: Notification when Load status changed
- Parameter 27: Indicator modes
- Technical Data
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hank
Smart Plug
SKU: HKZW-SO01
Quickstart
This is a ****
On/Off Power Switch
for
U.S. / Canada / Mexico.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
Set the Z-Wave network main controller into learning mode. Short press the
Z-button, the LED will keep turning on or off, which indicates the inclusion
is successful.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Smart Plug is a Z-Wave Switch plugin module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report wattage consumption or kWh energy usage.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press and hold the Z-button for more than 20 seconds, the LED will blink faster and faster when the button is pressed. If holding time more than 20seconds, the LED indicator will be on for 3 seconds then it blinking slowly, which indicates the reseting is successful. Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Set the Z-Wave network main controller into learning mode. Short press the Z-button, the LED will keep turning on or off, which indicates the inclusion is successful.
Exclusion
Set the Z-Wave network main controller into remove mode. Triple click the Z-button, the LED will blink slowly, which indicates the inclusion is successful.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Group 1 is assigned to the Lifeline association group and every device
has 5 nodes to associate. When the switch is turned on or off , the switch
will send a basic report of its status to the nodes in association group 1. To
change what kind of signal is sent to the nodes in group 1, please see the
detailed description of configuration parameter 24.
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 151: Threshold of change in wattage
The value here represents minimum change in wattage (in terms of wattage)
for sending a METER REPORT (for wattage) to the associated device (Group
Lifeline).
Size: 2 Byte, Default Value: 50
SettingDescription
0 | The function is disabled |
---|---|
1 – 65535 | The minimum change value in wattage for sending a meter report to |
the associated device
Parameter 152: Threshold of change in wattage percentage
The value here represents minimum change in wattage percent (in terms of
percentage) for sending a METER REPORT (for wattage) to the associated device
(Group Lifeline).
Size: 1 Byte, Default Value: 10
SettingDescription
0 | The function is disabled. |
---|---|
1 – 255 | The minimum change value in wattage percent for sending a meter |
report to the associated device
Parameter 171: Intervals of sending METER REPORT (for wattage)
The time interval of sending Meter Report (for wattage) to the associated
device (Group Lifeline).
Size: 4 Byte, Default Value: 30
SettingDescription
5 – 2678400 | The time for sending a meter report |
---|---|
0 | The function is disabled. |
Parameter 172: Intervals of sending METER REPORT (for kWh)
The time interval of sending Meter Report (for kWh) to the associated device
(Group Lifeline).
Size: 4 Byte, Default Value: 300
SettingDescription
5 – 2678400 | The time for sending a meter report |
---|---|
0 | The function is disabled. |
Parameter 173: Intervals of sending METER REPORT (for voltage).
The time interval of sending Meter Report (for voltage) to the associated
device (Group Lifeline).
Size: 4 Byte, Default Value: 0
SettingDescription
5 – 2678400 | The time for sending a meter report |
---|---|
0 | The function is disabled |
Parameter 174: Intervals of sending METER REPORT (for current).
The time interval of sending Meter Report (for voltage) to the associated
device (Group Lifeline).
Size: 4 Byte, Default Value: 0
SettingDescription
0 | The function is disabled |
---|---|
5 – 2678400 | The time for sending a meter report |
Parameter 20: Overcurrent protection
Smart Plug keep detecting the load current, once the current exceeds 16.5A
for more than 5 seconds, smart plug’s load will turn off.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | The function is disabled |
---|---|
1 | The function is enabled |
Parameter 21: Setting Smart Plugs load status after re-power on
Define Smart Plugs load status after re-power on.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | last status |
---|---|
1 | Always on |
2 | Always off |
Parameter 24: Notification when Load status changed
Smart Plug can send notifications to association device (Group Lifeline)
when state of smart plugs load changed.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | The function is disabled. |
---|---|
1 | Send BASIC REPORT |
2 | Send BASIC REPORT only when Load condition is changed not by Z-WAVE |
Command, such as short pressing.
Parameter 27: Indicator modes
After Smart Plug being included into a Z-Wave network, the LED in the device
will indicate the Smart Plugs load status.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | The LED will follow the status (on/off) of its load |
---|---|
1 | When the state of Switchs load changed, The LED will follow the status |
(on/off) of its load, but the red LED will turn off after 5 seconds if there is no any switch action.
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.03 |
Z-Wave Version | 6.51.07 |
Certification ID | ZC10-16065124 |
Z-Wave Product Id | 0x0208.0x0101.0x0005 |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>