FIBARO Smoke Sensor FIBEFGSD-002 Manual
- June 8, 2024
- FIBARO
Table of Contents
- Fibaro Group
- FIBARO Smoke Sensor
- SKU: FIBEFGSD-002
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Fibaro Smoke Sensor sensitivity
- Parameter 2: Z-Wave notifications status
- Parameter 3: Visual indicator notifications status
- Parameter 4: Sound notifications status
- Parameter 10: Configuration of control frames in BASIC command class
- Parameter 11: BASIC ON frame value
- Parameter 12: BASIC OFF frame value
- Parameter 13: Alarm broadcast
- Parameter 20: Temperature report interval
- Parameter 21: Temperature report hysteresis
- Parameter 30: Temperature threshold
- Parameter 31: Excess temperature signaling interval
- Parameter 32: Lack of Z-Wave range indication interval
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Fibaro Group
FIBARO Smoke Sensor
SKU: FIBEFGSD-002
Quickstart
This is a
secure
Alarm Sensor
for
Europe.
To run this device please insert fresh *1 CR123A** batteries.
Please make sure the internal battery is fully charged.
Fibaro Smoke Sensor inclusion:
1. Install the battery. Visual indicator will signal the Z-Wave network
inclusion status (green – device included, red – device not included)
2. Make sure the device is located within direct range of the Z-Wave
controller.
3. Set the main controller into the learning mode (see main controllers
operating manual).
4. Quickly, triple click the B-button, located on Fibaro Smoke Sensors
enclosure.
5. Fibaro Smoke Sensor will be detected and included in the Z-Wave network.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The FIBARO Smoke Sensor is a universal, ultra-light, perfectly designed, optical Z-Wave smoke detector. Fire alarm is signaled by sound, visual indicator blinking and alarm reports sent to the other devices within Z-wave network. The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover, the device has a built-in temperature sensor, which is adjustable to allow detection of fire by exceeding given temperature threshold. The FIBARO Smoke Sensor is a battery powered device designed to be placed on the wall or ceiling. Visual indicator signals fire, operating mode and it is used to check if the device is within the Z-wave network using a built-in Z-Wave range tester. The Smoke Sensor is designed to operate in confined spaces, under normal conditions (lacking of smoke, dust or condensed water vapor).
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1. Make sure the device has the battery installed.
2. Press and hold the B-button for 3 seconds. Visual indicator will glow
white.
3. You will hear a short signal.
4. Release the B-button.
5. Wait until the visual indicator glows yellow, signaling entering the 4th
menu level.
6. Press the B-button briefly to confirm menu level choice. At the same time
you will hear a short beep, the same sound as during the power connection.
Successful reset will be confirmed with the visual indicator changing colour
to red and fading. At the same time, short beep will sound, same as at the
power connection.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Basic activation
- Turn the cover counter-clockwise and open it
- Remove the battery blocker
- Install the sensor’s cover in desired location
- Screw the FIBARO Smoke Sensor into the cover
- Add the device
- Test FIBARO Smoke Sensor’s operation by performing a self-test – press & hold the B-button
- Test the Z-Wave network range assuring the device is within range
Installation notes
- Make sure the alarm sound can be easily audible in other rooms in the building.
- Install the sensor in already decorated, painted rooms.
- Install the sensor at least 1.5m from air conditioners.
- Do not install the sensor in direct sunlight. Keep at least 0.5m distance from light sources.
- Do not install the sensor in places prone to drafts.
- Do not install the sensor in places with high water vapor condensation, e.g. above stoves, ovens, kettles, etc. The device can not be installed in places where the temperature exceeds operational values (0°C – 55°C).
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Quickly, triple click the B-button, located on Fibaro Smoke Sensors enclosure.
Exclusion
Quickly, triple click the B-button, located on Fibaro Smoke Sensors enclosure.
Product Usage
Visual LED indicator
FIBARO Smoke Sensor is equipped with a LED diode, signalling sensor’s operating modes and alarms. In addition the visual indicator may inform of the Z-Wave network range or exceeding the temperature threshold.
Visual indicator signalling modes:
- Indication of alarms
- Added device status is signalled by a single green blink while inserting the battery
- Removed device status is signalled by a single red blink while inserting the battery
- Software update procedure is signalled by blinking in cyan
- Successful software update is signalled with glowing in green
- Unsuccessful software update is signalled with glowing in red
- MENU levels are signalled with glowing in certain colour
FIBARO Smoke Sensor is equipped with the MENU providing direct control over the device.
Press and hold the B-button for at least 3 seconds to enter MENU (visual
indicator will glow white).
Release the B-button – visual indicator will start changing colours in the
sequence.
Inside MENU, each of the positions will be signalled with a LED colour:
- WHITE – entering MENU confirmation
- GREEN – sending device state to associated devices
- VIOLET – Z-Wave network’s range test
- YELLOW – device reset
Confirm your choice with the B-button click.
Range test
FIBARO Smoke Sensor has a built-in Z-Wave network main controller’s range tester.
To make Z-Wave range test possible, the device must be added to the Z-Wave controller. Testing may stress the network, so it is recommended to perform the test only in special cases.
Follow the below instructions to test the main controller’s range:
- Press and hold the B-button
- Wait for the visual indicator to glow white and short acoustic signal to sound
- Release the B-button
- Wait for the visual indicator to glow violet
- Press the B-button again, briefly
- Visual indicator will indicate the Z-Wave network’s range (range signalling modes described below)
- To exit Z-Wave range test, press the B-button briefly
Z-Wave range tester signalling modes:
Visual indicator pulsing green – Smoke Sensor attempts to establish a direct
communication with the main controller. If a direct communication attempt
fails, the device will try to establish a routed communication, through other
modules, which will be signalled by visual indicator pulsing yellow.
Visual indicator glowing green – Smoke Sensor communicates with the main
controller directly.
Visual indicator pulsing yellow – Smoke Sensor tries to establish a routed
communication with the main controller through other modules (repeaters).
Visual indicator glowing yellow – Smoke Sensor communicates with the main
controller through the other modules. After 2 seconds the device will retry to
establish a direct communication with the main controller, which will be
signalled with visual indicator pulsing green.
Visual indicator pulsing violet – Smoke Sensor does communicate at the maximum
distance of the Z-Wave network. If connection proves successful it will be
confirmed with a yellow glow. It is not recommended to use the device at the
range limit.
Visual indicator glowing red – Smoke Sensor is not able to connect to the main
controller directly or through another Z-Wave network device (repeater).
Note: Communication mode of the Smoke Sensor may switch between direct and one using routing, especially if the device is on the limit of the direct range.
Fire detection
FIBARO Smoke Sensor responds to the physical presence of a smoke. The device checks every 10 seconds for a smoke. Once the level of smoke exceeds value set in advanced parameter 1, Smoke Sensor triggers an alarm.
Optical smoke detector used in FIBARO Smoke Sensor has 3 levels of sensitivity, compliant with EN 14604:2005. By default, the detector is set to the middle sensitivity level. Sensitivity level depends on the parameter 1 settings (modified only through the main Z-Wave controller).
Fire alarm is signaled by:
- sending an appropriate alarm command to the Z-Wave controller
- sending an appropriate alarm command to associated devices
- intermittent sound
- visual indicator blinking red
Once the fire alarm has ceased, the sensor checks whether the smoke has actually disappeared before getting back to normal operation, i.e. performing a self test each 10 seconds and checking for presence of smoke.
Note: FIBARO Smoke Sensor is a multiple use device, however, for greater safety, it is recommended to replace the device with a new one after a fire occurrence.
Note: If fire alarm is triggered, but the level of smoke did not exceed concentration equal to three times of the sensitivity set in parameter 1 (the individual levels of sensitivity are printed on the device casing), user can mute sound alarm by holding the B-button (temporarily reducing the sensor’s sensitivity).
Note: Visual indicator will still indicate an alarm state by blinking red. If smoke level concentration is greater than three times of the sensitivity set in parameter 1, mute will automatically turn off and the device will alarm fire again (using visual and audible indicator).
Excess temperature detection
Apart from detecting presence of smoke, FIBARO Smoke Sensor has an additional function of informing of exceeding the programmed temperature threshold. The function is disabled by default in parameter 2 settings.
Excess temperature warning is defined by user in parameter 30 – set to 55°C by default. Excess temperature level can be also signaled by visual indicator glow (parameter 3) and short beep (parameter 4). Parameter 20 should not be set to 0 because such setting disables temperature measurements.
Malfunction detection
FIBARO Smoke Sensor can automatically detect a malfunction. The device performs a test every 10 seconds. If malfunction is detected (e.g. damaged smoke chamber) an intermittent sound signal will start and alarm will be sent to the Z-Wave network controller.
Once trouble alarm has been detected, it is recommended to dismount the sensor and:
- check the power source (replace battery)
- check whether the Smoke Sensor is exposed to direct light
Note: If a malfunction alarm is continually reported, it is recommended to replace FIBARO Smoke Sensor with new one or contact with guarantor if the product warranty is still valid.
Self-test may be triggered manually:
- Make sure the device is powered
- Press and hold the B-button
- The visual indicator will glow white and the short alarm will sound
- Keep holding the B-button
- After 3 seconds from the first beep smoke chamber operation will be checked
Triggering fire alarm and beep mean positive result and should occur within 10 seconds. No fire alarm means that the sensor is malfunctioning.
Note : When the self-test is triggered manually the Smoke Sensor sends control command to the Z-Wave network controller. The procedure will be performed at least as long as the B-button is not released (will be completed in up to 10 seconds after releasing the B-button).
Note: Any service or repair must be carried out by the manufacturer. The expiry date of the device is indicated on its back.
Lack of Z-Wave range detection
When included in the Z-Wave network, FIBARO Smoke Sensor tests the network communication. By default the procedure is performed at each temperature report depending on parameters 20 and 21 settings. In addition, Z-Wave network communication test is performed during waking up. Lack of the Z-Wave network communication may be signaled by an intermittent alarm sound and visual indicator blinking violet.
By default sound and visual signals are disabled but you can enable it by changing values of parameters 3 and 4.
Once a FIBARO Smoke Sensor has reported no Z-Wave network communication, it is recommended to wake up the device by clicking the B-button. If it does not stop the alarm, Z-Wave networks operation and the main controllers operation need to be verified.
FIBARO Smoke Sensor will cancel the Z-Wave network communication alarm once it communicates with the network after manual or automatic wake up.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Available settings: 0 or 21 600 – 65 535 (in seconds, 6h – 18h)
Default setting: 21 600 (6h)
At each wake up Smoke Sensor communicates with the main controller, updates
parameters settings and the software if necessary. The Smoke Sensor will wake
up at defined time interval and will ALWAYS try to communicate with the main
controller. After each failed communication attempt, the sensor will retry to
establish connection with the main controller after 60 seconds. After 3 failed
attempts, the lack of the Z-Wave range alarm will be triggered. Longer time
interval means less frequent communication and thus a longer battery life. The
Z-Wave range alarm will be cancelled automatically, after first successful
connection. Change of wake up interval value does not affect alarms or trouble
signals operation.
Setting to 0 disables sending Wake Up Notification frame. Wake up may be still performed manually by a single B-button click or by sending Node Info frame (triple click the B-button).
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline. |
---|---|---|
2 | 5 | Trigger: Smoke alarm – association group, value depends on the |
configuration. Type of frame sent by the device when the association group is
activated: BASIC_SET.
3| 5| Trigger: Tamper – association group. Type of frame sent by the device
when the association group is activated: NOTIFICATION_REPORT.
4| 5| Trigger: Smoke alarm ZW3 – association group for ZW3 backward
compatibility. Type of frame sent by the device when the association group is
activated: SENSOR_ALARM_REPORT.
5| 5| Trigger: Tamper ZW3 – association group for ZW3 backward compatibility.
Type of frame sent by the device when the association group is activated:
SENSOR_ALARM_REPORT.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Fibaro Smoke Sensor sensitivity
There are 3 levels of sensitivity to smoke presence. Level 1 means the
highest sensitivity. Rising the parameter value lowers the sensitivity to
smoke presence.
Size: 1 Byte, Default Value: 2
SettingDescription
1 | HIGH Sensitivity |
---|---|
2 | MEDIUM Sensitivity |
3 | LOW Sensitivity |
Parameter 2: Z-Wave notifications status
This parameter allows to activate excess temperature and/or enclosure
opening notifications sent to the main controller.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | all notifications disabled |
---|---|
1 | enclosure opening notification enabled |
2 | exceeding temperature threshold notification enabled |
3 | all notifications enabled |
Parameter 3: Visual indicator notifications status
This parameter allows to activate visual indications but does not apply to
major alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | all notifications disabled |
---|---|
1 | enclosure opening notification enabled |
2 | exceeding temperature threshold notification enabled |
4 | lack of Z-Wave range notification |
Parameter 4: Sound notifications status
This parameter allows to activate sound signals but does not apply to major
alarms, such as FIRE, TROUBLE and LOW BATTERY ALARM.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | all notifications disabled |
---|---|
1 | enclosure opening notification enabled |
2 | exceeding temperature threshold notification enabled |
4 | lack of Z-Wave range notificatio |
Parameter 10: Configuration of control frames in BASIC command class
This parameter defines which frames will be sent in the 2-nd Association
Group (FIRE ALARM). The values of BASIC ON and BASIC OFF frames may be defined
as described in further parameters.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | BASIC ON & BASIC OFF enabled |
---|---|
1 | BASIC ON enabled |
2 | BASIC OFF enabled |
Parameter 11: BASIC ON frame value
BASIC ON frame is sent in case of smoke presence detection and Fire
Alarmtriggering. Its value is defined by the parameter.0 turn off the device.
Size: 2 Byte, Default Value: 255
SettingDescription
0 – 99 | set the device to 1-99% |
---|---|
255 | set the last status |
Parameter 12: BASIC OFF frame value
BASIC OFF frame is sent in case of Fire Alarm cancellation. Its value is
defined by the parameter.0 turn off the device1-99 set the device to 1-99%255
set the last status
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 99 | set the device to 1-99% |
---|---|
255 | set the last status |
Parameter 13: Alarm broadcast
A value other than 0 means that alarms are being sent in broadcast mode,
i.e. to all devices within a FIBARO Smoke Sensor’s range.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | broadcast inactive |
---|---|
1 | FIRE ALARM broadcast (2nd & 4th Association Group) active; enclosure |
opening notification broadcast (3rd & 5th Association Group) inactive
2| FIRE ALARM broadcast (2nd & 4th Association Group) inactive; enclosure
opening notification broadcast (3rd & 5th Association Group) active
3| FIRE ALARM broadcast (2nd & 4th Association Group) active; enclosure
opening notification broadcast (3rd & 5th Association Group) active.
Parameter 20: Temperature report interval
Time interval between consecutive temperature reports.
Report is sent when new temperature value is different from the one previously
reported – according to the set hysteresis (parameter 21). Temperature reports
can be also sent as a result of polling.
Size: 2 Byte, Default Value: 1
SettingDescription
0 | reports inactive |
---|---|
1 – 8640 | [10s-24h] Default setting: 1 (10 seconds) |
Parameter 21: Temperature report hysteresis
The temperature report will only be sent if there is a difference in
temperature valuefrom the previous value reported, defined in this parameter
(hysteresis).Temperature reports can be also sent as a result of polling.
Size: 1 Byte, Default Value: 10
SettingDescription
1 – 100 | (multiply by 0.1) [0.1°C – 10°C] Default setting: 10 (1°C) |
---|
Parameter 30: Temperature threshold
Temperature value measured by the built-in temperature sensor above which
the excess temperature notification is sent (visual indication/sound/Z-Wave
report). CAUTION: Parameters 30, 31 and 32 are associated with parameters 2, 3
and 4 settings. Their modification may have no effect if configured
functionality is not activated in the corresponding parameter.
Size: 1 Byte, Default Value: 55
SettingDescription
1 – 100 | (1°C – 100°C) |
---|
Parameter 31: Excess temperature signaling interval
Time interval of signaling (visual indication/sound) excess temperature
level. CAUTION: Parameters 30, 31 and 32 are associated with parameters 2, 3
and 4 settings. Their modification may have no effect if configured
functionality is not activated in the corresponding parameter.
Size: 2 Byte, Default Value: 1
SettingDescription
1 – 8640 | (multiply by 10 seconds) [10s-24h] |
---|
Parameter 32: Lack of Z-Wave range indication interval
Time interval of signaling (visual indication/sound) lack of Z-Wave range.
CAUTION: Parameters 30, 31 and 32 are associated with parameters 2, 3 and 4
settings. Their modification may have no effect if configured functionality is
not activated in the corresponding parameter.
Size: 2 Byte, Default Value: 180
SettingDescription
1 – 8640 | (multiply by 10 seconds) [10s-24h] |
---|
Technical Data
Dimensions | 65x65x28 mm |
---|---|
Weight | 42 gr |
Hardware Platform | ZM5202 |
EAN | 5902020528265 |
IP Class | IP 20 |
Battery Type | 1 * CR123A |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-15070004 |
Z-Wave Product Id | 0x010F.0x0C02.0x1002 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Sensor Alarm
- Application Status
- Association
- Association Group Information
- Basic
- Battery
- Configuration
- Crc 16 Encap
- Device Reset Locally
- Firmware Update Md
- Manufacturer Specific
- Multi Channel Association
- Sensor Multilevel
- Notification
- Powerlevel
- Security
- Version
- Wake Up
- Zwaveplus Info
Controlled Command Classes
- Basic
- Time Parameters
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>