Danfoss Hydronic Controller 10 DANEHC10 Manual

June 8, 2024
Danfoss

Danfoss

Hydronic Controller 10

SKU: DANEHC10

Quickstart

This is a ****

Barrier Operator
for
Europe
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
Press the button

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

Danfoss Link HC is part of the wireless control system” for heating systems in residential buildings,” controlled by the central controller Danfoss Link” CC.” The Danfoss Link HC enables the control of” of hot water underfloor heating systems.” The system offers a wide range of” Extended functions for optimum comfort” and energy saving and also allows for” the individual room temperature control.”
The Danfoss Link HC includes the following Functions: 2-way radio transmission, up to 10 short-circuit-proof outputs for 24 V” NC or NO actuators, relays for the pumps and pumps” Boiler control, self-diagnostic program,” Contact for the absence function, Heating/Cooling function, regulation according to the ON/OFF or” PWM principle (pulse width modulation) etc.” The system can be configured from up to three Danfoss Link HC” up to 30 outputs for larger systems can be connected to the system.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

– Disconnect the Hydronic Controller from the power supply.”

– Wait until the green LED goes out.

– Press and hold the installation button (9) and hold it down.

– Reconnect the power supply while holding down the installation button.

– Release the button as soon as the power LED (10) lights up.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Hydronic Controller

Mount the Hydronic Controller horizontally upright.

Mounting on Wall: Remove the front and side covers. Mount the controller with screws and plugs.

24V Actuators

– Connect the two actuator cables to the output (4).

– Fix the cable (8).

Note! ” NC (Normally Closed) configuration of the actuator output is preset.

Relays for pump and heater control

– Connect the pump and heater control cables to the respective output (2/3).

– Fix the cable (7).

Note! ” The pump and heater relays are floating contacts and can therefore NOT be used for” a direct power supply can be used. The maximum load is 230 V and 8 A/2 A.

Power supply

Connect all actuators before connecting the device to the power supply!” After you have installed all actuators, pump and heater controls as well as other inputs, connect the power plug of the Hydronic Controller to a 230V power source.”
Note! ” If the mains plug is disconnected from the power supply cable during installation, make sure that it is reconnected in accordance with the applicable guidelines.

External antenna (not included)

An external antenna is used as an amplifier if the transmission is interrupted by the use of an external antenna in a” large buildings, heavy constructions or metal barriers, e. g. if the Hydronic” controller is installed in a metal cabinet or box.

– Break out the plastic plug above the antenna connection of the Hydronic Conntrollers.”

-” Connect the external antenna (A).

– Position the antenna on the other side of the obstacle.


Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Press the button

Exclusion

Press the button

Product Usage

1. Output LED‘s
2. Boiler Relay
3. Pump Relay
4. Output 1 – 10
5.” Front cover release button
6. Input 1 – 3 (not use)
7.” Cable attachment for relay
8. Cable attachment for outputs
9. Connect button
10. Power – LED”
A. External antenna

LED indicator

Green ” …” The Hydronic controller has been added to a Z-Wave network.
Green flashing ” …” The Hydronic Controller has NOT been connected to a Z-Wave network.
Fast green flashing ” … Connection to the network is established. This process can also be carried out so quickly that no flashing to is recognizable.
Red ” …” The instrument is reset to the factory settings.
Red flashing ” …” Error mode for one or more thermostats.

Output LED 1 – 10

Off ” …” The valve for the chain is closed.
Green ” …” The valve for the chain is open.
Green flashing ” …” There is an error in the chain or an indication is required.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Valve Type (root only)

__
Size: 1 Byte, Default Value: 0

SettingDescription

0 Normally closed
1 Normally open

Parameter 2: Heat Load Strategy (root only)

__
Size: 0 Byte, Default Value: 0

SettingDescription

0 Stacking
1 Spreading

Parameter 3: PWM period

__
Size: 1 Byte, Default Value: 2

SettingDescription

0 Short (15 min)
1 Medium (30 min)
2 Long (60 min) (default)

Technical Data

Dimensions 325 x 78 x 47 mm
Weight 518.23 gr
Hardware Platform ZM3102
EAN 5702425190506
IP Class IP 30
Voltage 230 V
Load 35 VA
Device Type Barrier Operator
Network Operation Not Z-Wave+
Z-Wave Version 4.55.00
Certification ID ZC08-16010004
Z-Wave Product Id 0x0002.0x0248.0xA030
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Association
  • Association Group Information
  • Basic
  • Configuration
  • Device Reset Locally
  • Indicator
  • Manufacturer Specific
  • Multi Channel
  • Multi Channel Association
  • Notification
  • Switch Binary
  • Thermostat Mode
  • Thermostat Setpoint
  • Version

Controlled Command Classes

  • Sensor Multilevel

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.