APG DST-2421 DST Mid-Range Ultrasonic Sensor Installation Guide
- June 8, 2024
- APG
Table of Contents
APG DST-2421 DST Mid-Range Ultrasonic Sensor
Description
The DST series is APG’s line of ultrasonic sensors used in conjunction with a DCR controller to give you a simplified, stand-alone system. The transmit and receive circuit is built into the sensor and digitally communicates the detected distance to the DCR controller. This allows the sensor to be separated from the DCR controller by up to 2000 feet (610 meters) with no signal loss.
How To Read Your Label
Each label comes with a full model number, a part number, and a serial number. The model number for your DST will look something like this:
- SAMPLE: DST-2421-C10
The model number tells you exactly what you have. You can also call us with the model, part, or serial number and we can help you. You’ll also find all hazardous certification information on the label.
Warranty
This product is covered by APG’s warranty to be free from defects in material and workmanship under normal use and service of the product for 24 months. For a full explanation of our Warranty, please visit https://www.apgsensors.com /about-us/terms-conditions. Contact Technical Support to recieve a Return Material Authorization before shipping your product back.
Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone.
Dimensions
Installation Guidelines
Your DST should be installed in an area–indoors or outdoors–which meets the following conditions:
- Ambient temperature between -30°C and 60°C (-22°F to +140°F)
- Ample space for maintenance and inspection
Additional care must be taken to ensure:
- The sensor has a clear, perpendicular sound path to the surface being monitored.
- The sensor is mounted away from tank or vessel walls and inlets.
- The sound path is free from obstructions and as open as possible for the 9° off-axis beam pattern.
- The sensor is tightened by hand to avoid cross-threading.
Important: For the user interface guide and sensor configuration, see the DCR-1006A user manual.
IMPORTANT: Refer to section 10 for Hazardous Location Wiring.
Connecting to a DCR
DCR-1006A wiring terminals are accessible by unscrewing and then lifting off the front (top) face.
Sensor Wiring
NOTE: For programming the DCR-1006A controller, please see the DCR-1006A User Manual.
General Care
Your ultrasonic sensor is very low maintenance and will need little care as long as it was installed correctly. However, in general, you should periodically inspect your DST sensor to ensure the sensor face is free of any buildup that might impede the function of the sensor. If sediment or other foreign matter becomes trapped on the sensor face, detection errors can occur.
If you need to remove the sensor, be sure to store it in a dry place at a temperature between -40° and 180° F.
Repair Information
If your DST ultrasonic sensor needs repair, contact us via email, phone, or online chat on our website. We will issue you an RMA number with instructions.
- Phone: 888-525-7300
- Email: sales@apgsensors.com.
- Online chat at www.apgsensors.com.
Hazardous Location Wiring
Installation In Class I Division 2 Groups C and D ClassLone 2 A Ex nA IIB.
-
Hazardous Area
-
Non-Hazardous Area
-
WARNING
POTENTIAL ELECTROSTATIC CHARGING HAZARD – Clean only with a damp cloth -
AVERTISSEMENT
Surtace non conductrice du boitier peuvent être facturės par MEDIA non conductrice, CLEAN avec un chiffon humide -
Install in accordance with Section 18 of the CEC or Article 500 of the NEC.
-
CSA-listed or NRTL/UL-listed conduit seal at locations A & B.
-
The cable is potted into the sensor and runs continuously from the sensor through the Hazardous area and into the Non-Hazardous area.
-
Electrical equipment connected to associate ted Paratus should n0t generate more than c50 V RMS.
-
Tampering or replacement WIth non-factory components may adversely affect the state use of the system.
Automation Products Group, Inc.
1025 West 1700 North
Logan, Utah USA
888.525.7300