resideo FY32 Braukmann Instruction Manual
- June 8, 2024
- resideo
Table of Contents
resideo FY32 Braukmann Instruction Manual
Safety Guidelines
- Follow the installation instructions.
- Use the appliance
- according to its intended use
- in good condition
- with due regard to safety and risk of danger.
- Note that the appliance is exclusively for use in the applications detailed in these installation instructions (see 2 Technical Data). Any other use will not be considered to comply with requirements and would invalidate the warranty.
- Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons.
- Immediately rectify any malfunctions which may influence safety.
Technical Data
Media
Medium| Water, oil, compressed air
and other non-aggressive
mediums
Connections/Sizes
Connection sizes:| 1/4″ – 2″
Pressure values
Max. operating pressure:| 16 bar for water, oil and
compressed air
Operating temperatures
Max. operating temperature
medium:| 150 °C
Specifications
Installation position:| In horizontal or vertical
pipework with blanking plug
downwards
Assembly
Installation Guidelines
It is necessary during installation to observe codes of good practice, to comply with local requirements and to follow the installation instructions. The installation location should be protected against frost and be easily accessible.
Assembly instructions
- Thoroughly flush pipework
- Close valves
- Install the Y strainer
- Where possible, fit in horizontal pipework.
- Seal plug pointing downwards
- Slowly open valves
Maintenance
In order to comply with EN 806-5, water fixtures must be inspected and serviced on an annual basis. As all maintenance work must be carried out by an installation company, it is recommended that aservicing contract should be taken out.
In accordance with EN 806-5, the following measures must be taken:
The strainers should be cleaned or replaced as appropriate for system
conditions.
- Close shut-off valves
- Open seal plug
- Remove strainer
- If this is not done, strainer blockage can occur, resulting in pressure loss and reducing water flow rate
- The strainers are of stainless steel. Red deposits from the pipework do not affect the function or filtering efficiency.
- Reassemble in the reverse sequence.
- Open shut-off valves
Disposal
Observe the local requirements regarding correct waste recycling/disposal!
Spare Parts
For Spare Parts visit homecomfort.resideo.com/europe.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>