clearwater ESTO Battery-Powered Sensor Basin Mixer Chrome Instruction Manual

June 9, 2024
clearwater

clearwater ESTO Battery-Powered Sensor Basin Mixer Chrome Instruction Manual
clearwater ESTO Battery-Powered Sensor Basin Mixer
Chrome

REMEMBER

Maximum water supply pressure 5 bar ( 75PSI ) Minimum water supply pressure 1 bar Maximum hot water supply temperature 70˚C Recommended hot water supply temperature 65˚C
If these temperatures or water pressure are exceeded, damage to the tap can result. A pressure reducing valve may be required to be fitted in high water pressure situations.
Product Overview

It is very important that you read through the following instructions BEFORE you install and use the tap.

PREPARATION

We strongly recommend installing particle filters and isolation valves to both hot and cold feeds. This will help to prevent premature failure of valves and make any future maintenence easier. Flush the plumbing system before installing the mixer tap. This is to void plumbing residues clogging the mesh of the aerated outlet, or possibly damaging the valve’s washers. This is especially important where extensive plumbing work has been carried out. First shut off your water heating system then, with your mains stop cock closed, open the lowest hot and cold taps in the house and allow to run until the cold storage tank and pipes are empty. (The hot water storage cylinder always remains full).

INSTALLATION

Tools Required (Not Included)

  • Cross-Headed Screwdriver

  • Goggles

  • PTFE Tape

  • Electric Drill

  • Torch

  • Adjustable Spanner

Install the Tap(Figure 1, 2)
Installation Instructions

  • Make sure that sealing washer has been fitted to the flange.
  • Pass all the tails individually through the tap hole. If needed, remove the hot and cold tails, then re-attach from below (hand tight only).
  • Slide the rubber washer and metal washer and fixing nut up the flexible hoses as pictured. Then screw the nut all the way up, making sure the tap is in the correct position before tightening the lock screws.

Connect the Hoses(Figure 3)
Installation Instructions
CAUTION: Risk of restricted water flow and product damage.

  • When installing the hose, please hold the hose with one hand and tighten the hex nut to prevent the hose from twisting as the nut rotates. When tightening the hex nut, please use appropriate force. Do not use excessive force.)
    Note:Supply hoses must not be taut, kinked, or twisted during installation. If the supply hoses must be coiled, maintain an inside diameter of 3”(76 mm).

Connect the Supplies(Figure 3)

  • Assemble the outlet hose to the tap.
  • Connect the supply hose with a red label to the hot supply and the supply hose with blue label to the cold supply. Tighten the supply hoses to the supply mains pipes by using the adjustable spanner.
  • Close the handle and open the isolation valves to check if there is any leakage.
  • Place a bucket under the outlet hose. Turn on the water supplies. Flush hot and cold water into a bucket for 1 minute to remove any debris.

Assemble the Control Box(Figure 4)
Installation Instructions

  • Connect the hose (a) of the control box.
    Note:   1) The (IN) of the control box should be in the upper position.
    2) If you need to disconnect the hose (a), press the blue part on both sides of the black connector to disconnect.

  • Connect the hose (b) and tighten the nut clockwise, make sure the two arrows are fit into each other.

  • Connect the hose (c) to the connector of the control box (the OUT direction).

Connect the Control Box to the Battery Box(Figure 5 Figure 6)
Installation Instructions
Installation Instructions

  • Fit wall plugs into drilled holes on the wall. Put and tighten screws into wall plugs to fix the battery box mounting seat onto the wall.
    Note: The concrete wall must be thicker than 30mm.\

  • Open the battery box to install 4PCS AA batteries (not provided by the manufacturer) in the right direction and insert battery box into battery retainer ring, fix the whole unit into the well-assembled mounting seat on the wall.

  • Connect the control box (d) and battery box (d).

USE GUIDE

  • 10±15%cm Sensor Function
  1. When in use, wave your hand within 10 cm from the window to activate the sensor function
  2. The sensor light flashes multiple times, which indicates the battery power is about to run out Please replace the battery in time; otherwise the sensor function won’t be used soon
  3. The water will automatically shut off if no waving operation is occurred within 3minutes for safe and economic water usage. Wave the hand to activate the sensor again.
    Sensor window

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

TROUBLESHOOTING

Symptoms Probable Causes Recommended Action
Continuous water flow Dirty sensor window Wipe sensor window with soft

fabric
Drops of water accumulate on the sensor window| Gently wipe off drops of water
Sensor function is activatedfar beyond 10cm| Contact customer service
Control box failure| Contact customer service
The flow is too small| Insufficient flow in the water supply| Increase system water supply
Filter of inlet is blocked| Clean dirty filter
Angle valve opening angle is not enough| Reopen the angle valve
LED light is not flickering. No water flow during use.| Dirty sensor window| Wipe sensor window with soft fabric
Power supply is abnormal or power is out.| Check the power supply or the circuit condition
Abnormal circuit board| Contact customer service
Control box failure| Contact customer service
LED light flashes when not in use| Dirty sensor window| Wipe sensor window with soft fabric
Abnormal circuit board| Repair or replace circuit board
LED flashes but no water flow during use| Angle valve is not open or opening angle is not enough| Reopen the angle valve
Incorrect waterway connection| Check the waterway and connect it properly
Solenoid valve failure| Contact customer service
Control circuit board failure| Contact customer service
LED flashes 5 times during use| Battery is about to run out| Replacement battery ASAP
LED flashes 10 times but no water flow| Battery exhausted| Replacement battery

In the unlikely event you find a part missing please contact our Customer Service Helpline on 01684 299555 for immediate despatch of part.

Dimension and Parts

Product DimensionsProduct
Instructions

In the unlikely event you find a part missing please contact our Customer Service Helpline on 01684 299555 for immediate despatch of part.

MAINTENANCE

IF THE FITTING BEGINS TO DRIP

  1. Turn off the water supply .
  2. Loosen the screw behind the handle. Remove the handle and valve.
  3. Carefully clean seating, rubber washer and ceramic disc
  4. Replace valve and handle, then turn on water supply..
  5. If problem persists contact our helpline quoting the product code.

Filter maintenance
Close the check valve, and then turn the knob marked IN counterclockwise on the control box to remove the filter, and clean the filter with a soft brush.
Filter maintenance

Where an aerator is fitted to the outlet of the spout, it will need occasional cleaning. This will be evident when the water flow slows down to an unacceptable level. To accomplish this unscrew the outlet in an anti-clockwise direction and remove the mesh. Immerse the mesh in a suitable descaling fluid overnight, rinse throughly in clean water and re install.

AFTER CARE

To maintain the appearance of this tap, ensure that it is regularly cleaned only using a clean, soft damp cloth. A solution of warm water and a mild liquid detergent may be used where necessary, and then the fitting rinsed thoroughly and wiped dry. Abrasive cleaners, scouring cleaners and acid cleaners must not be used under any circumstances. All bath cleaning powders and liquids will damage the surface of your fitting even the non scratch cleaners. Avoid contact with all solvents and any harsh household chemicals. You will damage the finish and void your guarantee.

GUARANTEE AND LIABILITY

In the unlikely event that you should experience any defect in the material or workmanship of your mixer tap within 5 years of purchase, we will replace the faulty part free of charge. Decorative surface finishes are guaranteed for one year from the date of purchase provided that our advise concerning care has been observed and no scouring agents have been used. This is provided that the mixer or tap has been used for normal domestic purposes in the UK and that the care, installation and maintenance instructions have been observed.
Scuff and scratches caused by normal wear and tear, improper installation or accidental damage are excluded from this guarantee.
You should retain a copy of your dated invoice as proof of purchase to validate any claims under this guarantee.
No other warranties, express or implied, are made, including merchantability or fitness for a particular purpose.

Spare Parts and Service

Contact: Sterling
Phone: 01684 299555
Fax: 01684 290958
Email: [email protected]