Introduction
This product kills harmful bacteria with high-temperature steam and helps you to sterilize various kinds of baby feeding supplies safely and quickly. This product can hold 6 baby bottles of any brand and any size, or even supersized baby bottles. Besides, it can also accommodate other baby feeding products, such as complementary food bowls, cups and spoons. This product has multiple functions: warming milk, reheating foods, steaming eggs, and sterilizing/drying baby bottles and utensils.
Feature Diagram
- The above illustrations are for reference only.
Specifications
- Model Number: NU-MX100P
- Power Source: 220 – 240 V ~ 50 – 60 Hz
- Input power Sterilizer: 550 W
- Input power Dryer: 170 W
- Outside dimensions (H x W x D): 373 mm x 304 mm x 232 mm Weight (approx.): 2.5 kg
- Specifications subject to change without notice.
For the batch number (model number) and manufacturer, refer to the identification plate of the product.
Usage
Control Panel
- Follow as below steps before first using:
- Measure 90 ml water with the measuring cup (maximum 200 ml) and pour it into the water storage tank of the base.
- Place the body on the base and cover it with the lid.
- Insert the power supply cord, turn on the power supply, press the Power Pad “ ” to activate the product.
- Press the Sterilizing Pad “ ” to start the sterilization mode.
- The product starts to generate steam when the water temperature reaches 100℃, and automatically shuts down when the water is completely boiled away.
- After sterilizing, allow to cool for 3 minutes, and then disconnect the power and unplug.
- Remove the lid and the body, pour out the remaining water in the water storage tank of the base, and dry the product for normal use next time.
Milk Warming Function
- Measure 90 ml water with the measuring cup (maximum 200 ml) and pour it into the water storage tank of the base.
- Place the body on the base, put the container (baby bottle, cup or bowl) with milk and water on a stable place in the body, and then cover it with the lid.
- Turn on the power supply, press the Power Pad “
- Press the Warm-milk Pad “ ” , and then press the Pads “ ” and “ ” to select the desired time of 3-15 minutes. *The default setting to milk warming is 6 minutes.
- If there is no further operation in 3 seconds, it will enter working state after a “Beep” sound.
- The product heats the water in the water storage tank quickly to turn it into steam for heating. The product will beep 3 times and the indicator will flash after the program.
Referential Time Chart for Warming Milk
Water volume| Milk volume| Time for 5 ℃ cold milk| Time
for 20 ℃ milk at room temperature
---|---|---|---
90 ml| 60-120 ml| 3 minutes| 3 minutes
120-180 ml| 5 minutes| 3 minutes
180-270 ml| 6 minutes| 4 minutes
270ml| 7 minutes| 5 minutes
- Data prepared by Panasonic with test conditions – ambient temperature 25℃, one PP material 300 ml wide-neck bottle, and indicated milk temperature and milk volume in chart.
Note:
You may turn off the product manually and take out the baby bottle when the
milk temperature is appropriate.
- Drip the milk on the back of your hand to test the temperature before feeding
Reheating/Steaming Function
- Measure 90 ml water with the measuring cup (maximum 200 ml) and pour it into the water storage tank of the base.
- Place the body on the base, put the container with food (of proper volume) on a stable place in the body, and then cover it with the lid.
- Turn on the power supply, press the Power Pad “
- Press the Reheating/Steam Pad “ ” to enter this program, and press the Pads “ ” and “ ” to select the desired time of 3-15 minutes.
- The default setting for reheating/steaming is 6 minutes.
- If there is no further operation in 3 seconds, it will enter working state after a “Beep” Sound.
- The product heats the water in the water storage tank quickly to turn it into steam for heating. The product will beep 3 times and the indicator will flash after the program.
- The food should not be heated for too long.
Sterilizing Function
- Measure 90 ml water with the measuring cup (maximum 200 ml) and pour it into the water storage tank of the base.
- Place the body on the base, put the baby bottles, teats and other small items to be sterilized in the body of the product, and cover it with the lid.
- Turn on the power supply, press the Power Pad “
- Press the Sterilizing Pad “ ” to enter this program, and the product will enter working state after a “Beep” if there is no further operation in 3 seconds.
- The product will beep 3 times and the indicator will flash after the water is dried up and the program finishes.
Note: The water storage tank of the base can hold water up to 200 ml. It
is recommended that at least 90 ml of water should be added. The more water is
added, the longer the working time will be. The product can work for about 20
minutes at most or until it automatically shuts down.
Referential Chart for Added Water and Approximate Sterilization Duration
Added water volume | 90 ml | 120 ml | 150 ml | 200 ml |
---|---|---|---|---|
Sterilization duration | 7-10 mins | 10-13 mins | 12-17 mins | 18-23 mins |
- Data prepared by Panasonic with test conditions – ambient temperature 25℃, three 250 ml wide-neck bottles and nipples, three 250 ml narrow-neck bottles and nipples, and indicated water volume in chart.
- There is still residual heat on the sterilized items when the product just finishes the work. Pay attention to the residual heat before use.
Drying Function
- Place the body on the base, put the baby bottles, teats and other small items to be dried in the body of the product, and cover it with the lid.
- Turn on the power supply, press the Power Pad “
- Press the Drying Pad “ ” to enter this program, and press the Pads “ ” and “ ” to select the desired time of 40, 60 or 80 minutes.
- The default setting time for drying is 40 minutes.
- If there is no further operation in 3 seconds, it will enter working state after a “Beep” Sound.
- The product will beep 3 times and the indicator will flash after the program.
Sterilization/Drying Function
- Measure 90 ml water with the measuring cup (maximum 200 ml) and pour it into the water storage tank of the base.
- Place the body on the base, put the baby bottles, teats and other small items to be sterilized/dried in the body of the product, and cover it with the lid.
- Turn on the power supply, press the Power Pad “
- Press the Sterilizing/Drying Pad “ ” to enter this program, and press the Pads “ ” and “ ” to select the desired drying time of 40, 60 or 80 minutes.
- The default setting time for drying is 40 minutes.
- The product will start the sterilization mode after 3 seconds without further operation and a “Beep” sound. After the water is dried up and the sterilization finishes, the product will automatically enter the drying mode and continue to work.
- The product will beep 3 times and the indicator will flash after the program.
Note:
- The water storage tank of the base can hold water up to 200 ml. It is recommended that at least 90 ml of water should be added. The more water is added, the longer the working time will be. The product can sterilize for about 20 minutes at most or until it automatically enters the drying mode.
- The default drying time is 40 minutes, you can select the above-mentioned time according to your needs.
- There is still residual heat on the sterilized items when the product just finishes the work. Pay attention to the residual heat before use.
Graphical operation steps
Maintenance
- Water to use
It is recommended to use pre-boiled or filtered water to reduce the generation of scale.
- Cleaning water storage tank
It is recommended to descale the product every 1-2 weeks to ensure it works at
100% efficiency. The citric acid and white vinegar are good choices to descale
the product, and for the descaling method, you may refer to the instructions
on the package or just do as follows (the following heating function does not
include drying).
When using citric acid: Dissolve 1 packet (10g) of citric acid in 150 ml
of water, pour the solution into the water storage tank of the base, press
“Power” and press “Reheating/Steam”, and let the product work for 1-2 mins.
Cut off the power supply and rest the solution in the tank for 30 mins. Pour
it out, rinse the tank thoroughly and dry. When using white vinegar: Dilute 30
ml of white vinegar with 120 ml of cold water, pour the solution into the
water storage tank of the base, press “Power”, press “Reheating/Steam”, and
let the product work for 1-2 mins. Cut off the power supply and rest the
solution in the tank for 30 mins. Pour it out, rinse the tank thoroughly and
dry.
Cleaning air filter
The filter at the bottom of the base can be removed for cleaning. After
cleaning, re-install it on the base with the silver side outward.
- Before using citric acid, read the instructions carefully. Do not touch eyes. Place it beyond the reach of children.
Q & A
-
What items can be put into the product for sterilization?
Generally, items that can withstand high temperature above 100 °C and release no hazardous substance after being heated can be sterilized (for details, refer to the instructions of these items or consult professionals), such as PP bottle, glass bottle, silicone bottle, pacifier, teether, safe tableware made of safe materials. -
Is there any strict requirements for water quality?
Generally, for sterilization, purified water or treated drinking water is recommended. Untreated tap water has a lot of impurities and is more likely to produce scale. This will increase the cleaning difficulty and may affect the normal operation of the product. -
Why is the sterilization time too short?
The reason why the sterilization time is too short may be the water added is too little. Generally, the recommended minimum amount of water to be added is about 90 ml. It is appropriate to maintain a sterilization time of 10-15 minutes. -
Why are there still water droplets on some items after drying?
The drying effect will be affected if too many items are placed or items are placed too densely or at improper angles. It is recommended to sterilize and dry items in batches, or appropriately increase the drying duration and frequency. -
Why are there still water drops on the inner wall of Body (near the overlap between Lid and Body) after drying cycle completes?
During the drying process, the water steam condenses into water drops trapped in the overlap between Lid and Body, and can’t be fully dried up. When Lid is opened, some water drops slide down the inner wall of Body from the overlap. The water condensation can be reduced by longer drying duration.
Warning
- Read the Operating Instructions carefully before using the product and keep it properly for future reference.
- Before sterilization, clarify the reliability of the item to be sterilized, and make sure that it can withstand high temperature above 100℃ and release no hazardous substance after being heated.
Precautions:
- Check whether the product is damaged and whether the accessories are complete after package is removed.
- Make sure the product is placed on a smooth and steady surface when working.
- When the product works under sterilization mode, boiling hot steam will come out from the lid. Do not place any items on the lid.
- Place the product beyond the reach of children.
- Do not open the lid during the sterilization process. If the sterilization process is stopped within 6 minutes after it starts, the item inside may not be sterilized fully.
- After use, cut off the power and pour out the remaining water in the product.
- Do not sterilize any item without water.
- If the power supply cord is damaged or the machine malfunctions, unplug the power plug immediately, and do not make the defective product in working condition. Immediately request your retailer for inspection or repair to prevent danger.
- This product is not recommended for persons with disabilities, sensory or mental disabilities or personnel (including children) lack of relevant experience and knowledge, unless there is person who guards their safety to supervise and instruct them in the use of this product.
- Take care of children to ensure they will not play with this product.
- Make sure water has been added before powering on the product.
- It is forbidden to immerse the base in water.
- The product has the drying function, and the base is designed with an air outlet. Avoid water entering the air outlet, otherwise, components may be damaged.
- Read the Operating Instructions carefully and use this product correctly
Panasonic Corporation
Website: http://www.panasonic.com
© Panasonic Corporation 2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>