swim fun 1812 Salt Chlorinator Instruction Manual
- June 9, 2024
- swim fun
Table of Contents
swim fun 1812 Salt Chlorinator
INSTALLATION DIAGRAM
- Cell
- Electronics unit
- Electrode
- Bracket
- Electrical power supply
- Copper cable
- Filter
- Ground rod
- Heat pump
- Filtration pump
ELECTRONICS UNIT
Interface
ELEMENT | STATUS | MEANING |
---|---|---|
Red LED | Continuously on | Electronics unit powered off |
Flashing | Alarm activated | |
Green LED | Continuously on | Production in progress |
__
Screen
| Default display| Production setpoint
Flashing display| Information awaiting validation, or alarm
Frozen display| Confirmed information
Switching on
- When connecting the electronics unit to a power supply :
- After about a minute, production starts automatically, according to the setpoint displayed on the screen.
- If the electronics unit is powered off (screen off, red LED on) :
- Press at least twice on the upper control key. After about a minute, production starts automatically, according to the setpoint displayed on the screen.
Switching off
Set the production setpoint to 00 using the top key (no confirmation required)
: after a few seconds, the screen turns off and the red LED comes on.
Adjustment of the inversion frequency of the current supplying the cell (optional)
Water hardness (°f)| 0 to 2| 2 to 5| 5 to 8| 8 to 12| 12 to 20| 20 to
40| 40 to 60| > 60
---|---|---|---|---|---|---|---|---
Water hardness (mg/L)| 0 to 20| 20 to 50| 50 to 80| 80 to 120| 120 to
200| 200 to 400| 400 to 600| > 600
Reversal frequency (h)| 16| 14| 12| 10| 8| 6| 4| 2
- Press and hold down the bottom key, until the message In is displayed.
- Press the bottom key : the current setting flashes.
- Select an inversion frequency using the top key.
- Confirm with the bottom key : the display freezes for a moment
Setting the production setpoint
- Possible settings : from 00 to 10, in increments of 1.
- Default setting : 10.
Boost mode (optional)
- Boost mode sets the production setpoint to its maximum for 24 hours, but can be stopped at any point.
- This function is used when chlorine is urgently needed
- Boost mode continues after powering off the electronics unit.
- When the Boost mode terminates or stops, production continues according to the initial setpoint.
- Switching on : Press the bottom key : the message bo appears.
- Switching off : Press the top key.
Cover” or “Ext” socket (optional)
The socket marked “Cover” or “Ext” (depending on the model of the electronics unit) is used to connect a flow sensor, or an external control, or a cover position switch.
Pre-configuration
- Press and hold down the bottom key, until the message In is displayed.
- Press on the top key x times until the message CG is displayed.
- Press the bottom key (one of the following displays will flash).
- Using the top key, move to position :
- CF, for connection to a flow sensor
- CE, for connection to an external control
- Co, for connection to a cover position switch
- oF to deactivate the “Cover” socket (default setting).
- To confirm, press the bottom key : the display freezes for a moment
Production operation depending on the type of element connected
If flow sensor or external control (default configuration in NO switch) :
- When the switch is activated, production follows the setpoint as shown on the screen.
- When the switch is not activated, production is stopped. The message oF appears.
If cover position switch (default configuration in NO switch) :
- When the switch is activated, production is reduced by 25 % in relation to the setpoint. The message Co appears.
- When the switch is not activated, production follows the set point as shown on the screen.
To switch from a NO switch (normally open) to an NC switch (normally closed), or vice versa :
- Carry out steps 1 to 4 below.
- Press and hold down the 2 keys: the current switch flashes nO or nC.
- Using the top key, select an nO or nC switch.
- Confirm with the bottom key : the display freezes for a moment
Alarms
- Any alarm that is activated : – immediately displayed on the screen.
- Any alarm that is activated : – automatically and instantly stops production.
- Any alarm that is activated : – manually dismissed pressing and holding down the bottom key.
Message
displayed
| Fault
detected
| Cause| Checks and solutions
---|---|---|---
A1
|
Production anomaly
| Low water| Check that the pipe at cell level is completely filled with water, and
the flow is sufficient.
Low salt
| – Check the salt levels in the pool using a recent testing kit.
– Top up the salt, if necessary, so as to achieve a salt content of 5 kg/m3 (or 2.5 kg/m3 if Low Salt equipment).
Problem in the cell
| – Check that the electrical connections to the terminals of the cell are sufficiently tight and not oxidised.
– Check that the cell’s power cable connector is correctly connected to the electronics unit.
– Check that the cell is not scaled.
– As a last resort, replace the cell.
Problem in the
electronics unit
| Contact a professional to repair the electronics unit
A2
|
Short- circuiting of the equipment
|
Problem in the cell
| – Check that the electrical connections to the terminals of the cell are sufficiently tight and not oxidised.
– Check that the cell’s power cable is in good condition.
– As a last resort, replace the cell.
Problem in the
electronics unit
| Contact a professional to repair the electronics unit
ACTIVATING/DISABLING ALARM A1 :
- Press and hold down the bottom key, until the message In is displayed.
- Press the top key x times, until the message AL is displayed.
- Press the bottom key (one of the following displays will flash.
- Using the top key, move to position On to activate alarm A1 or to oF to disable alarm A1.
- To confirm, press the bottom key : the display freezes for a moment
GUARANTEE
Before contacting your dealer, please have the following to hand :
- your purchase invoice.
- the serial no. of the electronics unit.
- the installation date of the equipment.
- the parameters of your pool (salinity, pH, chlorine levels, water temperature, stabilizer level, pool volume, daily filtration time, etc.)
Every effort and all our technical experience has gone into designing this equipment. It has been subjected to quality controls. If, despite all the attention and expertise involved in its manufacture, you need to make use of our guarantee, it only applies to free replacement
Guarantee period (proven by date of invoice)
- Electronics unit : 2 years.
- Cell : – 1 year minimum outside the European Union (excluding warranty extension).
- Cell : – 2 year minimum in the European Union (excluding warranty extension).
- Repairs and spare parts : 3 months.
The periods indicated above correspond to standard guarantees. However, these can vary depending on the country of installation and the distribution network.
Scope of the guarantee
The guarantee covers all parts, with the exception of wearing parts that must
be replaced regularly. The equipment is guaranteed against all manufacturing
defects within the strict limitations of normal use.
AFTER-SALES SERVICES
All repairs will be performed in the workshop. Shipping costs in both
directions are at the user’s own expense. Any downtime and loss of use of a
device in the event of repairs shall not give rise to any claim for
compensation. In all cases, the equipment is always sent at the user’s own
risk. Before taking delivery, the user must ensure that it is in perfect
condition and, if necessary, write down any reservations on the shipping note
of the carrier. Confirm with the carrier within 72 hours by recorded letter
with acknowledgement of receipt. Replacement under guarantee shall in no case
extend the original guarantee period
Guarantee application limit
In order to improve the quality of their products, the manufacturer reserves
the right to modify the characteristics of the products at any time without
notice. This documentation is provided for information purposes only and is
not contractually binding with respect to third parties. documentation.
Installation, maintenance and, more generally, any servicing of the
manufacturer’s products should only be performed by professionals. This work
must also be carried out in accordance with the current standards in the
country of installation at the time of installation. The use of any parts
other than original parts voids the guarantee ipso facto for the entire
equipment
The following are excluded from the guarantee :
- Equipment and labour provided by third parties in installing the device.
- Damage caused by installation not in compliance with the instructions.
- Problems caused by modifications, accidents, misuse, negligence of professionals or end users, unauthorised repairs, fire, floods, lightning, freezing, armed conflict or any other force-majeure events.
- Any equipment damaged due to non-compliance with the instructions regarding safety, installation, use and maintenance contained in this documentation will not be covered by the guarantee.
- Every year, we make improvements to our products and software. These new versions are compatible with previous models. The new versions of hardware and software cannot be added to earlier models under the guarantee
Implementation of the guarantee
For more information regarding this guarantee, contact your dealer or our
After-Sales Service. All requests must be accompanied by a copy of the
purchase invoice.
Legislation and disputes
This guarantee is subject to French law and all European directives or
international treaties in force at the time of the claim, applicable in
France. In case of disputes concerning its interpretation or execution, the
High Court of Montpellier (France) shall have exclusive jurisdiction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>