FLUKE 771 Milliamp Process Clamp Meter Owner’s Manual

June 9, 2024
FLUKE

FLUKE 771 Milliamp Process Clamp Meter

FLUKE-771-Milliamp-Process-Clamp-Meter-product

Key features

  • Measures 4 to 20 mA signals without breaking the loop
  • Best in class with 0.2% accuracy
  • Delivers 0.01 mA resolution and sensitivity
  • Measures mA signals for PLC and control system analog I/O
  • Detachable clamp for measurements in tight locations

Product Overview

Save time by measuring 4-20 mA signals without breaking the loop.

The Fluke 771 delivers all the basic functionality you would expect in a milliamp clamp meter. It measures 4-20 mA signals without “breaking the loop,” allowing you to measure low-level DC current without having to take systems offline for troubleshooting, saving downtime and money. You can also use it to measure output signals from transmitters without breaking the loop when maintaining and troubleshooting processes and automation equipment. This saves time and avoids disrupting critical processes so you can avoid expensive downtime. You can also measure 10 to 50 mA signals in older control systems using the 99.9 mA range.

Added convenience
Designed to make troubleshooting easier, the Fluke 771 includes a detachable clamp that can be attached to the wire you’re testing while you move the meter—connected by the extension cable—to a better viewing position. This is especially helpful for taking readings in tight locations. With the dual backlit display showing both the mA measurement and the percent of a 4 to 20 mA span you can quickly understand what your system is doing, and a built-in LED spotlight lets you illuminate hard-to-see wire in dark enclosures. You can also capture and display changing measurements using the Hold function making it easier to verify and record measurements.

Specifications

Specifications

Diameter of measurable conductor| 0.177 in or 4.5 mm max|
Operating temperature| -10 to 50°C
Storage temperature| -25 to 60°C
Operating humidity| < 90% @ < 30°C, < 75% @ 30 to 55°C
Operating altitude| 0 to 2000 m
IP rating| IP 40
Size| 59 x 38 x 212 mm (2.32 x 1.5 x 8.35 in)
Weight| 260 G, (9.1 oz)
Vibration| Random 2 g, 5 to 500 Hz
Shock| 1 m drop test (except the jaw)


EMI/RFI

| Meets EN61326-1
For current measurement w/ JAW, add 1 mA to specification for EMC field strengths of 1 V/m up to 3 V/m.


Temperature coefficient

| 0.01% °C

(< 18°C or > 28°C)

Power, battery life| (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical


Warranty

| Three years for electronics

One year for cable and clamp assembly

Functional Specifications



mA measurement (measured by clamp)

| Resolution/range| 0 to 20.99 mA|
Accuracy| 0.2% + 2 counts
Resolution/range| 21.0mA to 100.0 mA
Accuracy| 1% + 5 counts

Ordering information

Fluke 771
Fluke 771 Milliamp Process Clamp Meter

Includes:

  • Soft Carrying Case
  • Users Manual

Fluke. Keeping your world up and running.

Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.

For more information call:
In the U.S.A. 800-443-5853
In Canada (800) 36-FLUKE
From other countries +1 425-446-5500
www.fluke.com.

©2022 Fluke Corporation.
Specifications are subject to change without notice.
03/2022

Modification of this document is not permitted without written permission from Fluke Corporation.

https://www.fluke.com/en-us/product/calibration-tools/ma-loop- calibrators/fluke-771.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals