DANCOVER st18122 Storage Tent PRO 4m Series PVC/PE User Manual
- June 9, 2024
- DANCOVER
Table of Contents
DANCOVER st18122 Storage Tent PRO 4m Series PVC/PE
Safety Advice
Attention
In some countries approval is needed to set up a tent larger than 75 m2. It is
your responsibility to comply with local rules and regulations and to ensure
that the tent is assembled correctly.
In case of bad weather conditions, it is your responsibility to ensure the
tent is safely secured and that the tent does not cause damage to others.
Do not use open fire, welding equipment or other sources which can ignite,
inside or close to the tent.
The tent must be safely secured. We recommend you secure your tent with straps
and pegs as soon as it is assembled.
Make sure to check if the tent is covered by your home contents insurance.
Tents must be evacuated under extreme weather conditions.
In the event of snow, always remove snow from the roof of the tent regularly
to prevent snow from building on the roof, as heavy snow can cause the tent to
collapse.
In the event of rain, there is a risk of rain puddles building up on top of
the roof of the tent. Heavy rain puddles can cause the roof to collapse. It is
your responsibility to ensure rain puddles do not build up. As a precaution,
make sure the roof of the tent is stretched out properly and adequately over
the side frames of the tent and remove rain water regularly.
Do not unpack or repack your tent in freezing temperatures. In case of
temperatures below zero, always unpack and repack your tent indoors to avoid
the risk of cracking parts.
The tent must be totally dry before you repack and store it to avoid mildew.
Note: Dancover warranty applies only to the normal use of the Product, normal wear and tear excepted, in accordance with written use instructions or manual. The warranty does not apply to damage caused by accident, abuse, misuse, or modification of the Product.
Warranty Information
Please visit dancovershop.com for information on warranty.
Please always check our website for the latest safety advice and manual.
Warning
- In order to avoid being rusted by air, oil is covered on the surface of the pipes. Before setting up the tent, please remove the oil carefully first to keep the cover clean.
- Take note that the tent needs to be handled carefully to avoid damage.
- Do not force the frames as they may be damage in the process.
- Tents are meant as temporary shelter, and must be evacuated under extreme weather conditions.
Please, select a suitable site for the tent to avoid the damage of underground sprinkler systems, water, gas or electrical lines.
Part no. | 4x10m | 4x12m | ||
---|---|---|---|---|
1 | Middle leg 1600mm 50-50 | 4 | 6 | |
2 | Frame pole 1880mm 38-38 | 39 | 46 | |
3 | Frame pole 1780mm 50-50 | 12 | 14 | |
4 | Frame pole 2030mm 50-50 | 8 | 10 | |
5 | Ceiling rail 2025mm 32-32 | 2 | 2 | |
6 | Diagonal support 1720mm 32-32 | 6 | 6 | |
7 | Roof support 1715mm 25-25 | 6 | 7 | |
8 | Frame pole 2030mm 50-50 | 4 | 4 | |
9 | Diagonal support 800mm 32-32 | 4 | 4 | |
10 | Female doorbar 2025mm 32-32 | 2 | 2 | |
11 | Lower leg 1600mm 50-50 | 8 | 8 |
12
| Strengthen bar 1480mm 32-32| | 2| 2
13| Strengthen bar 1845mm 32-32| | 2| 2
A| 3-way connector 54-42/3 rings|
| 6| 6
B| 4-way connector 54-42/4 rings| | 12| 15
14| 3-way conntector 54-42| | 4| 4
15| 4-way connector 54-42| | 8| 10
16| 3-way connector for corner| | 2| 2
17| 3-way connector for corner| | 2| 2
18| 3-way connector for sidewall| | 8| 10
19| 2-way connector for enwall| | 2| 2
20| Ceiling rail 1430mm 32-32| | 2| 2
21| Bracket| | 12| 14
22| Ground bracket| | 10| 12
23| Strengthen bar 1855mm 25-25| | 20| 24
24| Turnbuckle for door 5130mm| | 4| 4
25| Turnbuckle for roof 2840mm| | 20| 24
26| Turnbuckle for side 3870mm| | 20| 24
27| Peg 10x350mm| | 20| 24
28| Spiral peg| | 4| 4
29| Small peg| | 44| 50
30| Bungeeball long| | 60| 60
31| M6 wingnut| | 24| 26
32| Screw M6x30mm| | 12| 14
33| Screw M6x45mm| | 10| 10
34| Screw M6x65mm| | 2| 2
35| M6 nut| | 4| 4
36| Spanner| | 2| 2
37| Tie down| | 4| 4
38| Steel clip| | 70| 82
39| Screw M8x50mm| | 78| 92
40| Screw M8x65mm| | 80| 92
41| M8 nut| | 158| 184
42| Peg 16x600mm| | 18| 22
43| M12 washer| | 4| 4
44| M12 nut| | 4| 4
45| Screw M12x48mm| | 2| 2
46| Screw M12x65mm| | 2| 2
47| Sheaved block 1 wheel| | 2| 2
48| Sheaved block 2 wheel| | 2| 2
50| Roof| | 1| 1
51| Endwall|
| 2| 2
4×10-12×3.5m storage pro| Part 31| Part 32| Part 33| Part 34| Part 35| Part
39| Part 40| Part 41| Part 43| Part 44| Part 45| Part 46
---|---|---|---|---|---|---|---|---|---|---|---|---
M6 Wing nut| M6x30 Screw| M6x45 Screw| M6x65 Screw| M6 Nut| M8x50 Screw (Ø42)|
M8x65 Screw (Ø54)| M8 Nut| M12 Washer| M12 Nut| M12x48 Screw| M12x65 Screw
4×10| 4×12| 4×10| 4×12| | | | 4×10| 4×12| 4×10| 4×12| 4×10| 4×12| | | |
Used for Part 7 and Part 21| | | 12| 14| | | | | | | | | | | | |
Used for Part 6 and Part 20| | | | | 2| | | | | | | | | | | |
Used for Part 5 and Part 10| | | | | 2| | | | | | | | | | | |
Used for Part 6 and Part 9| | | | | 4| | | | | | | | | | | |
Used for Sheaved block 1wheel Part 47| | | | | 2| | 2| | | | | | | | | 2|
Used for Sheaved block 2 wheel Part 48| | | | | | 2| 2| | | | | | | | | | 2
Used for M6x30| 12| 14| | | | | | | | | | | | | | |
Used for M6x45| 10| 10| | | | | | | | | | | | | | |
Used for M6x65| 2| 2| | | | | | | | | | | | | | |
Used for 2-way connector 19| | | | | | | | 4| 4| | | | | | | |
Used for 3-way connector A| | | | | | | | 6| 6| 12| 12| | | | | |
Used for 4-way connector B| | | | | | | | 24| 30| 24| 30| | | | | |
Used for 3-way connector 14| | | | | | | | 4| 4| 8| 8| | | | | |
Used for 3-way connector 16| | | | | | | | 4| 4| 2| 2| | | | | |
Used for 3-way connector 17| | | | | | | | 4| 4| 2| 2| | | | | |
Used for 3-way connector 18| | | | | | | | 16| 20| 8| 10| | | | | |
Used for 4-way connector 15| | | | | | | | 16| 20| 16| 20| | | | | |
Used for Part 6 and Part 11| | | | | | | | | | 4| 4| | | | | |
Used for Part 9 and Part 11| | | | | | | | | | 4| 4| | | | | |
Used for M8x50| | | | | | | | | | | | 78| 92| | | |
Used for M8x65| | | | | | | | | | | | 80| 92| | | |
Used for M12x48| | | | | | | | | | | | | | 2| 2| |
Used for M12x65| | | | | | | | | | | | | | 2| 2| |
| 24| 26| 12| 14| 10| 2| 4| 78| 92| 80| 92| 158| 184| 4| 4| 2| 2
Select a flat surface at ground for the tent, unpack the carton and check all
the parts including tubes, tent and accessories… etc. are present and the same
as the list.
Assemble the framework of rooftop by joining the portion (A, B) together with
poles (2, 4, 8) NO. 11 is on four corners for diagonal pipe.
To ensure the screw fixed to every pole tightly. And then use the turnbuckle
set which is diagonally across through each section as below.
Attach one end of supported pole (3) to the joints. If you want the rope pull
at the opposite side than shown in the drawing then switch sheaved block (47)
and (48)
Attach the other supported poles (1, 2, 11) to the joints, built-up the
framework. NO. 11 is on four corners for diagonal pipe.
You facilitate the assembly and dismantling by pulling the roof with ropes on
tent frame. Use the steel clips to fasten the cover to the frame. Each section
we offer bracket and nail to fasten the frame to ground.
Spread the wall panel and door panel attach to framework by using the bangee cords clasping the frame to grommets that is construct over the wall panel and door panel to ensure stability. Also use the short pegs to fix the doors to the ground.