OSS-CPCIe3-3U-10GbE-x4-QUAD Ethernet Adapter Installation Guide
- June 9, 2024
- OSS
Table of Contents
- OSS-CPCIe3-3U-10GbE-x4-QUAD Ethernet Adapter
- Getting Started
- Unpacking
- Description of Parts
- Module Installation
- SFP module and Cable Installation
- Turning ON the Device
- LED Panel Indicator
- Verify Device Installation
- Troubleshooting
- Contacting Technical Support
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CPCIe3-3U-10GbE-x4-QUAD Ethernet Adapter
Installation Guide
OSS-CPCIe3-3U-10GbE-x4-QUAD Ethernet Adapter
INSTALLATION GUIDE
OSS-CPCIe3-3U-10GbE-x4-QUAD
www.onestopsystems.com
Getting Started
This installation guide tells you step by step how to install the module. You will find instructions for the following procedures:
- Unpacking
- Description of Parts
- Module Installation
- SFP module and Cable Installation
- Turning ON the Device
- SFP module and Cable Installation
- LED Panel Indicator
- Verify Device Installation
Unpacking
Check and identify the standard supplied item. Inspect the card / module to
make sure it is free from physical defects / damages.
Description of Parts
Side
Module Installation
-
Turn the chassis off and unplug the chassis from AC power.
-
Before inserting the module, inspect the chassis slot to ensure there aren’t any bent pins in the slot connectors.
-
Set the injector /ejector handle in down position.
Caution:
To avoid damaging the module, do not touch exposed board end connectors or components on the printed circuit board when installing the module. -
Slowly insert the module in the chassis slot by placing the module card edges into the top and bottom card guides. With the injector/ejector handle in the down position, carefully slide the module to the rear of the chassis. Caution:
Ensure that the module is aligned perpendicularly to the chassis as you begin sliding it in. Otherwise, it’s possible for components on the module (or on adjacent modules) to be damaged by contact between modules. -
When you begin to feel resistance from the backplane connectors, push up on the injector/ejector handle to complete insertion of the module and latch it into place.
-
Secure the module front panel to the chassis using the captive front panel mounting screws. The module has two captive mounting screws.
a. 1st mounting screw on top
b. 2nd mounting screw (bottom) beneath the injector/ejector
SFP module and Cable Installation
Carefully insert SFP+ Cable (Fiber or Cat6) to any available port on the module.
5.1 Supported SFP and SFP module
What are the SFP+ and SFP module requirements for the Intel® Ethernet
Converged Network Adapter X520 Series?
Check Intel website for further information on the supported SFP and SFP
modules.
https://www.intel.com/content/www/us/en/support/articles/000005528/network-
and-i-o/ethernet-products.html
Turning ON the Device
Once the SFP modules are inserted correctly, you can turn ON the expansion
unit.
After the expansion unit is powered UP, the LED located on the front module
will illuminate depending on the link connection (either 1G or 10G).
LED Panel Indicator
- 10g: Indicates 10G link
- 1g: Indicates 1G link
Verify Device Installation
8.1 Linux
On Linux operating system, to verify or check if the device is detected or
not, type the command below on the terminal window
$ lspci –tv | grep 82599
See output below, four Intel 82599ES are detected. $ lspci –D | grep ‘Network|Ethernet’
See output below, four Intel 82399ES are detectedTo find out the
device assigned name, type the command below on the terminal window.
$ lspci – c network –businfo
See output below, four 82599ES are detected and each has their corresponding
device name (i.e. enp9s0f0) The following two photos below represent the
device slot address /B/D/F (Bus#, Device#, Function#) and its corresponding
physical SFP port on the card. ![OSS-CPCIe3-3U-10GbE-x4-QUAD Ethernet Adapter
- fig 13](https://manuals.plus/wp-content/uploads/2023/01/OSS-CPCIe3-3U- 10GbE-x4-QUAD-Ethernet-Adapter-fig-13.png)
The OSS-PXIE-10GBe-QUAD uses a PLX PEX 8732. You can check or query the PEX
8732 by using the command below on the terminal window
$ lspci –v | grep –I ‘PEX 8732’. See output below
8.1 Windows
Verify hardware device in Windows Operating System. As your Windows computer
starts up, you will see a small message box pop-up in the lower-right corner
of the screen to alert you that Windows has found new hardware.
Find the ‘My Computer’ icon and “right-click” on it. Then select ‘Manage’ from
the pop-up menu.
- Next, click on ‘Device Manager’ in the left most Computer Management window.
- Finally, click on the View Menu and select View Devices by Connection
- Open ACPI (BIOS) → Open PCI Bus→ Click the ‘+’ or ‘>” sign several times until you reach a PCI Express Root Port Complex.
- Then click or collapse all the ‘+’ or ‘>’ until you see multiple subsets of PCI standard PCI-to-PCI bridge. See screenshot below.
Right click the PCI standard PCI-to-PCI bridge with your mouse, then select properties. Select the “Details” tab, below the “Property”, select “Compatible Ids”, it will show the Vendor Device of 8732. This is the PEX 8732 chip on the card.
- All four “PCI standard PCI-to-PCI bridge” devices will have the same PCI\VEN DEV 8732
Collapse or click the ‘+’ or ‘>’ sign next to PCI standard PCI-to- PCI bridge and you will find four instances of Intel 82599 10 Gigabit Dual Port Network Connection devices, see screenshot below. The following four screenshots represent the “Bus#, Device#, Function#” and its corresponding physical SFP port on the card.
Troubleshooting
9.1 Device is not detected or recognized
- Shutdown the system
- Disconnect the SFP module and cables
- Disconnect the power from the unit
- Remove the OSS-529 module from the unit
- Check the slot inside the unit for damaged pins
- Re-insert the OSS-529 module
- Secure the OSS-520 module
- Reconnect the SFP module and cables
- Turn ON the unit
9.2 Device is recognized but the front LED indicator is not coming ON
- Re-seat the SFP module and cables
- Make sure you are using a compatible SFP modules and cables. Go to Chapter 5 section 1 (Supported SFP modules)
- Replace or swap the SFP module and cables
- Re-install the driver for the Intel82599
- Replace the OSS-520 card with a known good card
9.3 Intel82599 devices are showing UP with a Yellow Exclamation mark
- Install or re-install the Intel82599 driver
- Reboot the system after installing the driver
- Re-install OS
- Install Operating System updates.
9.4 Broken OSS-529 board
-
If you received a brand new DOA (Dead on Arrival) board, please contact OSS to RMA board and request for a replacement.
-
If you have an out of warranty board, please contact OSS Sales team and buy a new replacement board.
• Standard warranty is 1 year, unless you have an SLA or extended warranty coverage. -
If you purchased a second-hand / used board and it is broken, please contact OSS Sales team to buy a replacement.
• Note: Purchasing a second-hand / used product is not covered under warranty.
Contacting Technical Support
Our support department can be by phone at 1 760-745-9883. Support is available Monday through Friday, 8:00 AM to 5:00 PM PT. When contacting One Stop Systems Technical Support, please be sure to include the following information:
- Name
- Company Name
- Phone Number
- Fax Number
- Email Address
- Model Number| 7) Serial Number
- Computer Make
- Computer Model
- Operating System and Version
- Make/Model of accessories attached to the tablet
- Detailed description of the problem
---|---
- You can also visit our web site at: www.onestopsystems/support/
- OSS Sales Contact: sales@onestopsystems.com
- OSS Support Contact: support@onestopsystems.com
For a quick response, use the Technical Support and RMA Request Form available
in the Support Section of the website. Simply complete the form with all
required information. Please make sure that your problem description is
sufficiently detailed to help us understand your problem.
For example: Don’t say “Won’t boot up.” Do say “Tried all the steps in the
Troubleshooting Section and it still won’t boot up.”
For faster diagnosis of your problem, please run the two utility programs
described in the following sections and include the diagnostic files they
generate with your email.
10.1 Returning Merchandise to One Stop Systems
If factory service is required, you must contact OSS Service Representative to
obtain a Return Merchandise Authorization (RMA) number. Put this number and
your return address on the shipping label when you return the item(s) for
service. One Stop Systems will return any product that is not accompanied by
an RMA number. Please note that One Stop Systems WILL NOT accept COD packages,
so be sure to return the product freight and duties-paid.
Ship the well-packaged product to the address below:
RMA # ____
One Stop Systems
2235 Enterprise Street, Suite#110 92029
USA
It is not required, though highly recommended, that you keep the packaging
from the original shipment of your One Stop Systems product. However, if you
return a product to One Stop Systems for warranty repair/ replacement or take
advantage of the 30-day money back guarantee, you will need to package the
product in a manner similar to the manner in which it was received from our
plant. One Stop Systems cannot be responsible for any physical damage to the
product or component pieces of the product (such as the host or expansion
interfaces for the PCIe expansion chassis) that are damaged due to inadequate
packing. Physical damage sustained in such a situation will be repaired at the
owner’s expense in accordance with Out of Warranty Procedures. Please, protect
your investment, a bit more padding in a good box will go a long way to
insuring the device is returned to use in the same condition you shipped it
in. Please call for an RMA number first.
2235 Enterprise Street
Suite#llO, Escondido CA 92029
Toll-Free: +1(800)285-8900 US
Main: +l 760-745-9883
Fax: +l 760-745-9824
www.onestopsystems.com