BOSCH Atino Line Laser Instruction Manual

June 14, 2024
Bosch

BOSCH Atino Line Laser

BOSCH-Atino-Line-Laser-product

Product Information

  • Brand: Bosch Power Tools
  • Model: Atino
  • Manufacturer: Robert Bosch Power Tools GmbH
  • Country of Origin: Germany
  • Website: www.bosch-pt.com

Specifications

  • Battery Life: Minimum 5 hours
  • Weight: 0.26 kg
  • Laser Type: 630-650 nm, < 5 mW

Product Usage Instructions

Mounting

Battery Installation/Replacement

  1. Make sure to follow the correct polarity as indicated inside the battery compartment.
  2. If the battery is weak, the LED ring (2) will blink yellow three times after turning on. The device can still operate for approximately 15 minutes.

Attaching the Tool

Refer to the illustrations in the front section of the user manual for reference.

Pad Replacement and Attachment

Gelpad Replacement

  1. To replace the pads, rotate the gelpad holder (14) counterclockwise and remove the gelpad (15) and holder from the tool.
  2. Place the pinpad (6) and rotate it clockwise until it is securely fastened. To switch from pinpad to gelpad, follow the same steps.

Attaching with Gelpad

Requirements: The surface must be dry and firm.

  1. Place the tool on the surface: Rotate the protective cap (16) of the gelpad counterclockwise and remove it. Remove the protective film from the gelpad before first use.

Initial Setup

  1. Turn on the device.

Laser Line Leveling

The leveling state is indicated by the LED ring (2):

  • Red: Not level. Adjust until the laser line is horizontal or vertical.
  • No LED ring, laser line is on: The laser line is leveled.

Calibrating Laser Line

  • If the laser line is not aligned properly, perform the calibration again.

Safety Instructions

All instructions must be read and observed in order for the measuring tool to function safely. The safeguards integrated into the measuring tool may be compromised if the measuring tool is not used in accordance with these instructions. Never make warning signs on the measuring tool unrecognisable. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL WHEN TRANSFERRING IT TO A THIRD PARTY.

  • Warning:  If operating or adjustment devices other than those specified here are used or other procedures are carried out, this can lead to dangerous exposure to radiation.
  • The measuring tool is delivered with a laser warning sign (marked in the illustration of the measuring tool on the graphics page).
  • If the text of the laser warning label is not in your national language, stick the provided warning label in your national language over it before operating for the first time.

Do not direct the laser beam at persons or animals and do not stare into the direct or reflected laser beam yourself. You could blind somebody, cause accidents or damage your eyes.

  • If laser radiation hits your eye, you must close your eyes and immediately turn your head away from the beam.
  • Do not make any modifications to the laser equipment.
  • Do not use the laser goggles (accessory) as protective goggles. The laser goggles make the laser beam easier to see; they do not protect you against laser radiation.
  • Do not use the laser goggles (accessory) as sunglasses or while driving. The laser goggles do not provide full UV protection and impair your ability to see colours.
  • Have the measuring tool serviced only by a qualified specialist using only original replacement parts. This will ensure that the safety of the measuring tool is maintained.
  • Do not let children use the laser measuring tool unsupervised. They could unintentionally blind themselves or other persons.
  • Do not use the measuring tool in explosive atmospheres which contain flammable liquids, gases or dust. Sparks may be produced inside the measuring tool, which can ignite dust or fumes.

Keep the magnet away from implants and other medical devices, e.g. pacemakers or insulin pumps. The magnet generates a field that can impair the function of implants and medical devices.

  • Keep the measuring tool away from magnetic storage media and magneticallysensitive devices. The effect of the magnets can lead to irreversible data loss.

Product Description and Specifications

Please observe the illustrations at the beginning of this operating manual.

Intended Use

  • The measuring tool is intended for determining and checking horizontal and vertical lines on vertical surfaces. On horizontal or inclined surfaces, the non-levelled laser line can be used as reference.
  • The measuring tool is suitable for indoor use.
  • This product is a consumer laser product in accordance with EN 50689.

Product features

The numbering of the product features shown refers to the illustration of the measuring tool on the graphic page.

BOSCH-Atino-Line-Laser-fig-2

BOSCH-Atino-Line-Laser-fig-3

  1. On/off button
  2. Light-up ring
  3. Laser beam outlet aperture
  4. Battery compartment cover
  5. Locking mechanism of the battery compartment cover
  6. Pin pad
  7. Pin
  8. Magnet
  9. Serial number
  10. Tape measure housing
  11. Tape measure
  12. Laser warning label
  13. Addition to the laser warning label
  14. Holder for gel pad
  15. Gel pad
  16. Protective cap for gel pad
  17. Locking marking
  18. Marking aid

Technical data

Line laser /Atino

Article number 3 603 F63 A..
Laser line lengthA) 1.7 m
Levelling accuracy of visible laser line ±0.3°
Length of tape measure 1.5 m
Tape measure measuring accuracy ±2 mm/m
Tape measure accuracy class
Operating temperature +5 °C to +40 °C
Storage temperature –20 °C to +70 °C
Max. altitude 2000 m
Relative air humidity max. 90 %
Pollution degree according to IEC 61010-1 2B)
Laser class 2
Laser type 630–650 nm, < 5 mW
C6 5
Divergence 15 × 15 mrad (full angle)
--- ---
Battery 1 × 1.5 V LR6 (AA)
Operating time at least 5 h
Weight according to EPTA-Procedure 01:2014 0.26 kg
Dimensions (length × width × height) 124 × 115 × 62 mm

A) depending on surface characteristics and ambient conditions
B) Only non-conductive deposits occur, whereby occasional temporary conductivity caused by condensation is expected.

The serial number (9) on the type plate is used to clearly identify your measuring tool.

Assembly

Inserting/Changing the Battery

  • It is recommended that you use alkaline manganese batteries to operate the measuring tool.
  • Do not use lithium-ion batteries. This may result in damage to the measuring tool.

To open the battery compartment cover (4), press on the locking mechanism (5) and remove the battery compartment cover. Insert the battery. When inserting the batteries, ensure that the polarity is correct according to the illustration on the inside of the battery compartment. Close the battery compartment before using the measuring tool. If the battery is running low, the light-up ring (2) will flash yellow three times after the tool is switched on. The measuring tool can be operated for approx. another 15 min.

  • Take the battery out of the measuring tool if you do not intend to use the tool for a long time. When it is stored in the measuring tool for longer periods, the battery can corrode and discharge itself.

Attaching the Measuring Tool

Selecting/changing the pad

The measuring tool can be attached to walls or other vertical surfaces. Depending on the type of substrate, either the gel pad (15) or the pin pad (6) can be used. As a general rule: The gel pad (15) is suitable for smooth surfaces. The pin pad (6) is suitable for coarse or rough surfaces and wallpaper on drywalls. The pin pad cannot be attached to concrete (regardless of the surface).

Substrate for attaching with the

BOSCH-Atino-Line-Laser-fig-8

To change the gel pad, turn the gel pad holder (14) anticlockwise and take the gel pad (15) and holder off the measuring tool. Attach the pin pad (6) and turn it clockwise as far as it will go. The same procedure should also be followed when switching from the pin pad to the gel pad.

Attaching with the gel pad

Requirements

  • The substrate must be dry and firm.
  • The gel pad is not guaranteed to stick to damp, particularly dusty, sharp-edged or highly textured surfaces. If attached to unsuitable surfaces such as these, the measuring tool can fall off and become damaged or damage the substrate.
  • If the gel pad becomes dirty or does not stick to smooth surfaces any more, it must be cleaned or replaced (see “Cleaning the Gel Pad”,).
  • Before every use, select an inconspicuous area lower down on the desired surface to check whether the gel pad will stick to this substrate, and that it can be safely removed without damaging the substrate.
  • Always remove the measuring tool once you have finished taking a measurement, or if the substrate is being worked on in some manner (e.g. drilling, screwdriving, or hammering).

Positioning the measuring tool on the substrate:

  • Turn the protective cap (16) of the gel pad anticlockwise and remove it. Remove the protective film from the gel pad before using it for the first time.
  • Gently press the measuring tool against the substrate until it is firmly affixed. Applying excessive pressure may damage the measuring tool.

Removing the measuring tool from the substrate:

  • Push the measuring tool carefully away from the substrate. Removing the measuring tool from a delicate surface too quickly can damage the substrate.
  • Place the protective cap (16) on the gel pad (15) so that the locking markings (17) on the protective cap and gel pad are pointing towards each other. Then turn the protective cap clockwise all the way.
  • The measuring tool should only ever be transported and stored with the protective cap attached. If the gel pad becomes dirty, it will lose its adhesive strength.

Attaching with the Pin Pad

  • The substrate must be dry and firm.
  • Insert the pins into the recesses on the pin pad. Ensure that the pins are securely affixed to the substrate.
  • Always remove the measuring tool once you have finished taking a measurement, or if the substrate is being worked on in some manner (e.g. drilling, screwdriving, or hammering).

Operation

Starting Operation

Special Safety Instructions for Operation

  • Protect the measuring tool from moisture and direct sunlight.
  • Do not expose the measuring tool to any extreme temperatures or variations in temperature. For example, do not leave it in a car for extended periods of time. In case of large variations in temperature, allow the measuring tool to adjust to the ambient temperature before putting it into operation. The precision of the measuring tool may be compromised if exposed to extreme temperatures or variations in temperature.
  • Avoid substantial knocks to the measuring tool and avoid dropping it. Damaging the measuring tool can cause accuracy to be compromised. Calibrate the measuring tool after it has been dropped or subjected to heavy impact. Check the laser line by comparing it with a known horizontal or vertical reference line.

Switching On/Off

To switch on the measuring tool, briefly press the On/off button (1). The light-up ring (2) flashes green three times when the battery has sufficient capacity. The laser line lights up immediately after switching on the measuring tool.

  • Do not direct the laser beam at persons or animals and do not stare into the laser beam yourself (even from a distance).
  • To switch off the measuring tool, briefly press the on/off button (1) again.
  • Never leave the measuring tool unattended when switched on, and ensure the measuring tool is switched off after use. Others may be blinded by the laser beam.
  • If no button on the measuring tool is pressed for approx. 15 minutes and the housing is not rotated, the measuring tool will automatically switch off to preserve battery life.

Levelling a Laser Line

When attaching the measuring tool vertically, the laser line can either be levelled horizontally to the right (90°) or left (270°), or vertically upwards (0°) or downwards (180°). If the measuring tool is not aligned vertically, the laser line can only be used as a non-levelled reference line. The levelling status is indicated by means of the light-up ring (2):

BOSCH-Atino-Line-Laser-fig-9

Working Advice

Working with the Tape Measure

The zero point of the tape measure (11) is situated in the centre of the marking aid (18), it can be marked directly on the substrate.

Note: The zero point marking can be offset by up to ±1 mm compared to the laser line.

Pull the tape measure housing (10) away from the measuring tool and mark additional points at the required distances at the height of the laser line. Do not pull the tape measure (11) out any further than up to the end of the imprinted scale. You can double the work area by placing the measuring tool in the middle of the work surface and measuring on two sides one after the other. The tape measure will roll itself up again automatically.

Note: Do not let go of the unrolled tape measure (11). Uncontrolled retraction may damage the tape measure.

Calibrating the Laser Line

  • Calibration should be carried out in the following cases:
    • After the tool has been dropped or subjected to heavy impact
    • Every 6 months
  • If necessary, check the levelling of the laser line on a known horizontal or vertical reference line.
  • Always perform a thorough and complete calibration to avoid incorrect measuring results.
    • Attach the measuring tool to a vertical surface.
    • While the measuring tool is either switched on or off, press the on/off button (1) for at least 3 s until the laser beam starts flashing and the light-up ring (2) is no longer lit.
    • Slowly and evenly rotate the housing of the measuring tool once by more than 360°.
  • The rotation should take at least 15 s.
    • The calibration process is completed successfully once the light-up ring (2) lights up green.
    • If the light-up ring (2) lights up red after calibration, the calibration has failed. Restart the calibration.

Maintenance and Service

Maintenance and Cleaning

  • Keep the measuring tool clean at all times.
  • Never immerse the measuring tool in water or other liquids.
  • Wipe off any dirt using a damp, soft cloth. Do not use any detergents or solvents.

Cleaning the Gel Pad

  • Clean the gel pad (15) whenever it has become contaminated with dust or other particles, or if its adhesive strength has been reduced.
  • Only wash the gel pad when it has been detached from the tool.

Rinse the gel pad (15) with water. Wash it as necessary using a common household neutral soap or a detergent. Do not use any cleaning agents that contain alcohol or solvents. Leave the gel pad, holder and protective cap to dry completely. The gel pad must not be warmed up (e.g. through warm air or heating).
If the adhesive strength is still not sufficient even after the gel pad (15) has been cleaned, it should be replaced.

After-Sales Service and Application Service

Our after-sales service responds to your questions concerning maintenance and repair of your product as well as spare parts. You can find explosion drawings and information on spare parts at: www.bosch-pt.com
The Bosch product use advice team will be happy to help you with any questions about our products and their accessories.
In all correspondence and spare parts orders, please always include the 10‑digit article number given on the nameplate of the product.

Great Britain

Disposal

  • Measuring tools, accessories and packaging should be recycled in an environmentally friendly manner.
  • Do not dispose of measuring tools or batteries with household waste.

Only for EU countries

According to the Directive 2012/19/EU on waste electrical and electronic equipment and its transposition into national law, measuring tools that are no longer usable, and, according to the Directive 2006/66/EC, defective or drained batteries must be collected separately and disposed of in an environmentally correct manner. If disposed incorrectly, waste electrical and electronic equipment may have harmful effects on the environment and human health, due to the potential presence of hazardous substances.

Only for United Kingdom

According to The Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) and the Waste Batteries and Accumulators Regulations 2009 (SI 2009/890) (as amended), products that are no longer usable must be collected separately and disposed of in an environmentally friendly manner.

Licenses

Copyright © 2012–2020 STMicroelectronics
All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  • Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  • Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
  • Neither the name of STMicroelectronics nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS “AS IS” AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

EU Declaration of Conformity

Line laser/ Article number

We declare under our sole responsibility that the stated products comply with all applicable provisionsof the directives and regulations listed below and are in conformity with the following standards.

The notified body no. 0071: National Metrology and Testing Laboratory (LNE), 1, rue Gaston Boissier, 75724 Paris Cedex 15, has carried out the testing in accordance with 2014/32/EU, Module D1 and issued the following certificate: no. LNE‑36144 Revision 3, dated 2022‑09‑12. Technical file at: *

BOSCH-Atino-Line-Laser-fig-5

Declaration of Conformity

Line laser/ Article number

  • Atino: 3 603 F63 A00

We declare under our sole responsibility that the stated products comply with all applicable provisions of the regulations listed below and are in conformity with the following standards.
Technical file at: Robert Bosch Ltd. (PT/SOP-GB), Broadwater Park, North Orbital Road, Uxbridge UB9 5HJ, United Kingdom

The Electromagnetic Compatibility Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
The Measuring Instruments Regulations 2016

  • EN 61010-1:2010+A1:2019
  • EN IEC 61326-1:2021
  • EN IEC 63000:2018

The UK Approved Body no. 8521: LNE‑GMED UK, Suite A First Floor, East Wing Focus 31, Mark Road, Hemel Hempstead, Hertfordshire, HP2 7BW, United Kingdom, certifies that the quality assurance system complies with The Measuring Instruments Regulations 2016, module D1 and issued the following certificate: No. UKCA‑38536 Revision 0, dated 2022‑11‑21.

BOSCH-Atino-Line-Laser-fig-6

Robert Bosch Power Tools GmbH

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals