PCE-MSR 50 Mini Magnetic Stirrer User Manual

June 9, 2024
PCE

PCE-MSR 50 Mini Magnetic Stirrer

PCE-MSR 50 Mini Magnetic Stirrer

User manuals in various languages (français, italiano, español, português, nederlands, türk, polski, русский, 中文) can be found by using our product search on: www.pce-instruments.com

PCE-MSR 50 Mini Magnetic Stirrer 1

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Do not use the magnetic stirrer with flammable, explosive or corrosive media.
  • Place the magnetic stirrer on a smooth and solid surface.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Technical specifications

Max. stirring volume 100 … 1000 ml
Adjustable speed 0 … 1600 rpm
Accuracy of speed ±20 rpm
Platform size Ø 88 mm
Platform material Plastic
Protection class IP21
Power supply 90 … 230 V AC / 5 V DC
Input ≤15 W
Dimensions 125 x 110 x 70 mm
Weight Approx. 0.5 kg

Delivery contents

  • 1 x magnetic stirrer PCE-MSR 50
  • 1 x mains adaptor 5 V / 2 A
  • 1 x stirring bar
  • 1 x user manual

Operation

  1. Place the magnetic stirrer on a smooth and solid surface. The knob should be at minimum position.
  2. Connect the magnetic stirrer to the power supply.
  3. Place the beaker with the medium in the middle of the platform. To adjust the stirring speed, slowly turn the knob to the desired position. If you turn it too quickly, the liquid can spill. In this case, turn the knob back to minimum and then slowly increase the stirring speed again.
  4. Mixed samples of small volume should not be stirred at maximum speed to avoid the beaker from falling off the platform.

Cleaning

Clean the surface of the instrument with a cloth and some pH = 7 ±1 non- corrosive liquid detergent and make sure the instrument is completely dry before using it.

Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.

In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.

PCE Instruments contact information

Germany
PCE Deutschland GmbH
Im Langel 4
D-59872 Meschede
Deutschland
Tel.: +49 (0) 2903 976 99 0
Fax: +49 (0) 2903 976 99 29
info@pce-instruments.com
www.pce-instruments.com/deutsch

Germany
Produktions- und Entwicklungsgesellschaft mbH
Im Langel 26
D-59872 Meschede

Deutschland
Tel.: +49 (0) 2903 976 99 471 Fax: +49 (0) 2903 976 99 9971 info@pce- instruments.com
www.pce-instruments.com/deutsch
The Netherlands
PCE Brookhuis B.V.
Institutenweg 15
7521 PH Enschede

Nederland
Telefoon: +31 (0)53 737 01 92 Fax: +31 53 430 36 46
info@pcebenelux.nl
www.pce-instruments.com/dutch
United States of America
PCE Americas Inc.
711 Commerce Way suite 8 Jupiter / Palm Beach
33458 FL

USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
info@pce-americas.com
www.pce-instruments.com/us

France
PCE Instruments France EURL
23, rue de Strasbourg
67250 Soultz-Sous-Forets
France
Téléphone: +33 (0) 972 3537 17 Numéro de fax: +33 (0) 972 3537 18 info@pce- france.fr
www.pce-instruments.com/french

United Kingdom
PCE Instruments UK Ltd
Units 11 Southpoint Business Park Ensign Way, Southampton Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
info@industrial-needs.com
www.pce-instruments.com/english

Chile
PCE Instruments Chile S.A.
RUT: 76.154.057-2
Calle Santos Dumont N° 738, Local 4 Comuna de Recoleta, Santiago
Tel. : +56 2 24053238
Fax: +56 2 2873 3777
info@pce-instruments.cl
www.pce-instruments.com/chile

Turkey
PCE Teknik Cihazları Ltd.Şti.
Halkalı Merkez Mah.
Pehlivan Sok. No.6/C
34303 Küçükçekmece – İstanbul Türkiye
Tel: 0212 471 11 47
Faks: 0212 705 53 93
info@pce-cihazlari.com.tr
www.pce-instruments.com/turkish

Spain
PCE Ibérica S.L.
Calle Mayor, 53
02500 Tobarra (Albacete)

España
Tel. : +34 967 543 548
Fax: +34 967 543 542
info@pce-iberica.es
www.pce-instruments.com/espanol

Italy
PCE Italia s.r.l.
Via Pesciatina 878 / B-Interno 6 55010 Loc. Gragnano
Capannori (Lucca)

Italia
Telefono: +39 0583 975 114
Fax: +39 0583 974 824
info@pce-italia.it
www.pce-instruments.com/italiano

Hong Kong
PCE Instruments HK Ltd.
Unit J, 21/F., COS Centre
56 Tsun Yip Street

Kwun Tong
Kowloon, Hong Kong
Tel: +852-301-84912
jyi@pce-instruments.com
www.pce-instruments.cn

China
PCE (Beijing) Technology Co., Limited 1519 Room, 6 Building
Zhong Ang Times Plaza
No. 9 Mentougou Road, Tou Gou District 102300 Beijing

China
Tel: +86 (10) 8893 9660
info@pce-instruments.cn
www.pce-instruments.cn

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals