netvox R718MBB Wireless Activity Vibration Counter
Introduction
The R718MBB series equipment is a vibration alarm device for Netvox ClassA- type equipment based on the LoRaWAN open protocol. It can count the number of movements or vibrations of the device and is compatible with the LoRaWAN protocol.
LoRa Wireless Technology
Lora is a wireless communication technology dedicated to long distances and
low power consumption. Compared with other communication methods, LoRa spread
spectrum modulation method greatly increases to expand the communication
distance. Widely used in long-distance, low-data wireless communications. For
example, automatic meter reading, building automation equipment, wireless
security systems, and industrial monitoring. The main features include small
size, low power consumption, transmission distance, anti-interference ability,
and so on.
LoRaWAN
LoRaWAN uses LoRa technology to define end-to-end standard specifications to
ensure interoperability between devices and gateways from different
manufacturers.
Appearance
Main Features
- Compatible with LoRaWAN protocol.
- Powered by 2 x ER14505 3.6V Lithium AA battery
- Easy setup and installation
- Detectable voltage value and device movement status
Set up Instruction
Power on and Turn on / off
-
Power on open the battery cover; insert two sections of 3.6V ER14505 AA batteries and close the battery cover.
-
Turn on: i f the device had never joined in any network or at factory setting mode, after powering on, the device is at off mode
by default setting. Press and hold the function key for 3 seconds till the green indicator flashes once and release to turn on the device. -
Turn off: Press and hold the function key for 5 seconds till the green indicator flashes quickly and releases. The green indicator will flash 20 times to show that the device is turned off.
Note
-
The interval between shutting down twice or power off/on is suggested to be about 10 seconds to avoid the interference of
capacitor inductance and other energy storage components. -
Do not press the function key and insert batteries in the same time, otherwise, it will enter engineer testing mode.
-
Once the battery is removed, the device is at off mode by default setting.
-
Turn off operation is the same as Restore to Factory Setting operation.
Join Into LoRa Network
To join the device into the LoRa network to communicate with the LoRa gateway The network operation is as follows
- If the device had never joined any network, turn on the device; it will search for an available LoRa network to join. The green indicator will stay on for 5 seconds to show it joins into the network, otherwise, the green indicator will be off.
- If R718MBB had been joined into a LoRa network, remove and insert the batteries; it will repeat step (1).
Function Key
- Press and hold the function key for 5 seconds to reset to the factory setting. After restoring to the factory setting successfully, the green indicator will flash quickly 20 times.
- Press the function key to turn on the device that is in the network and the green indicator will flash once and the device will send a data report.
Data Report
When the device is turned on, it will immediately send a version package and
cluster report data . Data will be reported once per hour by default setting.
Maximum time: 3600s
Minimum time: 3600s (Detect the current voltage value every 3600s by default
setting)
Default report change
Battery 0x01 (0.1V)
Note
- The device periodically sends data according to the maximum interval.
- The data content is: R718MBB current vibration times 718MB B device will only report according to the minimum interval when battery voltage changes
R718MBB vibration times report
The device detects sudden movement or vibration waits for 5 seconds after
entering the stationary state counts the number of counts sends a report of
the number of vibrations and restarts a new round of detection. If the
vibration continues to occur during this process, the 5 seconds timing
restarts. Until it reaches a standstill. The count data is not saved when it
is powered off.
You can change the device type and active vibration threshold by using the gateway to send commands. R718MB DeviceType (1Bytes, 0x01_R718MBA, 0x02_R718MBB, 0x03_R718MBC), the default value is the programming value. The active vibration threshold range is 0x0003 0x00FF (default is 0x0003)
Data report configuration and send in g period are as follows
Min. Interval
(Unit: second)
| Max. Interval
(Unit: second)
|
Reportable Change
| Current Change≥
Reportable Change
| Current Change <
Reportable Change
---|---|---|---|---
Any number between
1~65535
| Any number between
1~65535
|
Can not be 0.
| Report
per Min. Interval
| Report
per Max. Interval
Restore to Factory Setting
R718MBB saves data including network key information, configuration information, etc T o restore to the factory setting, users need to execute the below operations.
- Press and hold the function key for 5 seconds till the green indicator flashes and then release the LED flash es quickly 20 times.
- R718MBB is at off mode by default setting after restoring to the factory setting.
Note: The device operation of turning off is the same as the Restore Factory Settings operation
Sleeping Mode
R718MBB is designed to enter sleeping mode for power saving in some
situations:
- While the device is in the network the sleeping period is Min Interval. (During this period, if the report change is larger than the setting value, it will wake up and send a data report
- When it is not in the network R718MBB will enter sleeping mode and wake up every 15 seconds to search a network to join in the first two minutes. After two minutes, it will wake up every 15 minutes to request to join the network. If it at (B) status, to prevent this unwanted power consumption, we recommend that users remove the batteries to power off the device
Low Voltage Alarming
The operating voltage threshold is 3.2 V. If the battery voltage is lower than
3.2 V, R718MBB will send a low power warning to the Lo R a network
Installation
This product comes with a waterproof function. When using it, the back of it
can be adsorbed on the iron surface or the two ends can be fixed to the wall
with screws.
Note: To install the battery, use a screwdriver or similar tool to assist
in opening the battery cover.
Important Maintenance Instruction
Your device is a product of superior design and craftsmanship and should be
used with care. The following sug
questions will help you use the warranty service effectively.
-
Keep the equipment dry. Rain, moisture, and various liquids or moisture may contain minerals that can corrode electronic circuits. I n case t he device is wet, please dry it completely.
-
Do not use or store in dusty or dirty areas. This can damage its detachable parts and electronic components.
-
Do not store in excessive heat. High temperatures can shorten the life of electronic devices, destroy batteries, and deform or melt some plastic parts.
-
Do not store in a cold place. Otherwise, when the temperature rises to normal temperature, moisture will form inside, which
will destroy the board. -
Do not throw, knock or shake the device. Rough handling of equipment can destroy internal circuit boards and delicate structures.
-
Do not wash with strong chemicals, detergents or strong detergents.
-
Do not apply with paint. Smudges can block debris in detachable parts and affect normal operation.
-
Do not throw the battery into a fire to prevent the battery from exploding.
-
Damaged batteries may also explode.
-
All of the above suggestions apply equally to your device, battery, and accessories. If any device is not working properly
-
Please take it to the nearest authorized service facility for repair.
Information about Battery Passivation
Many of Netvox devices are powered by 3.6V ER14505 Li-SOCl2 (lithium-thionyl chloride) batteries that offer many advantages including low self-discharge rate and high energy density. However, primary lithium batteries like Li-SOCl2 batteries will form a passivation layer as a reaction between the lithium anode and thionyl chloride if they are in storage for a long time or if the storage temperature is too high. This lithium chloride layer prevents rapid self-discharge caused by continuous reactions between lithium and thionyl chloride, but battery passivation may also lead to voltage delay when the batteries are put into operation, and our devices may not work correctly in this situation. As a result, please make sure to source batteries from reliable vendors, and it is suggested that if the storage period is more than one month from the date of battery production, all the batteries should be activated. If encountering the situation of battery passivation, users can activate the battery to eliminate the battery hysteresis.
ER14505 Battery Passivation
To determine whether a battery requires activation Connect a new ER14505
battery to a resistor in parallel, and check the voltage of the circuit. If
the voltage is below 3.3V, it means the battery requires activation.
How to activate the battery
- Connect a battery to a resistor in parallel
- Keep the connection for 5~8 minutes
- The voltage of the circuit should be ≧3.3, indicating successful activation.
Brand | Load Resistance | Activation Time | Activation Current |
---|---|---|---|
NHTONE | 165 Ω | 5 minutes | 20mA |
RAMWAY | 67 Ω | 8 minutes | 50mA |
EVE | 67 Ω | 8 minutes | 50mA |
SAFT | 67 Ω | 8 minutes | 50mA |
Note
If you buy batteries from other than the above four manufacturers,
then the battery activation time, activation current, and
required load resistance shall be mainly subject to the announcement of each
manufacturer
Relevant Products
Model | Function | Appearance |
---|
R718MBB
| ****
Detect the movement or vibration of the device and triggers an alarm.
| ****
R718MBB
| ****
Counts the number of movements or vibrations of the device.
R718MBC
| ****
Counts the movement or vibration duration of the device.