Hwam 3520 Wood Burning Stove User Manual
- June 9, 2024
- Hwam
Table of Contents
User manual Hwam 3520
3520 Wood Burning Stove
|
---|---
HWAM® SmartControl™
Congratulations on your new wood-burning stove complete with a HWAM®
SmartControl™ We are pleased that you have chosen a HWAM woodburning stove and
confident that it will give you much pleasure.
The HWAM® SmartControl™ is a digital control of the combustion in your new
wood-burning stove. The purpose of the HWAM® SmartControl™ is to control the
combustion in an environmentally optimal and economically efficient way, with
a view to generating greater user comfort. The HWAM® SmartControl™ is a new
patented technology, which electronically adjusts the air supply to the
combustion chamber. Your new wood-burning stove continually measures the
temperature and the oxygen levels of the combustion. Moreover, it is
programmed to supply oxygen to the fire through three important air inlets in
the right amount, and at the right time and place in the combustion chamber.
By downloading a free app for your smartphone or tablet, you can use the app
among other things: to set the thermostat to the desired room temperature
level, choose time for night-time reduction and keep your stove updated. The
app also gives you current information on burning in the stove. See details in
separate manuals for the app IHS Smart Control™ or in the Quickguide.
Your new wood-burning stove and the HWAM® SmartControl™ will ensure the
cleanest possible combustion as well as a good fuel economy, regardless of
external conditions such as the type of firewood used, the chimney, the user’s
experience, and other external circumstances.
The HWAM® SmartControl™ consists of the following components:
- Air box: the Air box contains a printed circuit board/software, as well as three motors and dampers that control primary, secondary, and tertiary combustion air. The fresh air system can be mounted on the Air box to the back or in the bottom.
- Two sensors: a temperature sensor and an oxygen sensor transmit information from the wood-burning stove to the Air box.
- Room temperature sensor: The room temperature sensor with batteries communicates with the HWAM® SmartControl™ via a wireless connection. It should be placed so it does not have direct radiant heat from the stove. Note that the maximum distance between stove and room temperature indicator is about 4-5 metres. The range is reduced if there are walls or other obstructions between the stove and the room temperature indicator.
- Electricity supply: from the Air box to the nearest wall socket.
- App “IHS Smart Control™:The app can be downloaded free from the App Store or Google Play Store. See details in separate manuals for the app IHS Smart Control™ or in the Quickguide.
Installation
In general
To ensure optimum operation and safety, we recommend that the installation
should be carried out by an authorised HWAM retailer or a fitter recommended
by the retailer. For an overview of HWAM retailers, visit
www.hwam.com under “Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all
European, national and local building regulations. The installation must be
carried out in accordance with the instructions in the installation and user
manuals and subsequently registered with the local authorities. Upon
installation, the chimney sweep must approve the installation before you can
start using the woodburning stove. All HWAM woodburning stove packaging
material must be handled in accordance with local waste management
regulations.
Room requirements
It is required to have an approved CO monitor in the same room as the wood
burning stove. Always ensure a supply of fresh combustion air to the room
where the stove is to be installed. The woodburning stove uses approx. 4-15 m³
of air per hour. A window that can be opened or an adjustable air valve will
be sufficient. It must not be possible to block the adjustable air
valve/grate. In newly built/airtight dwellings, we recommend that a fresh air
system should be installed for the direct supply of external air to the
combustion. This fresh-air system may be bought separately. Before installing
the stove, you must ensure that the load-bearing capacity of the floor can
withstand the weight of the stove and the chimney. The weight of the chimney
should be calculated according to its dimensions and height. Remember to
consider that the stove must be connected to power. ”
Technical measures and data
Test results from nominal test EN 13240
Nominal heating effect| 4.5 kW
Flue gas temperature EN 13240 measurement point| 270ºC
Flue gas temperature measured in the outlet socket| 323ºC
Exhaust gas flow| 3.50 g/s
Efficiency| 81 %
Annual efficiency (EcoDesign)| 71 %
PM| 12 mg/m3
OGC| 59 mg/m3
NOx| 83 mg/m3
CO at 13% O2| 1050 mg/m3
CO at 13% O2| 0.0840 %
Energy efficiency index| 107
Energy efficiency class| A+
The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.
Model | Weight | Height | Width | Depth |
---|---|---|---|---|
HWAM 3520c/3520m | 118/115 kg | 126.0 cm | 54.0 cm | 37.1 cm |
HWAM 3520c/3520m, natural stone cladding | 155/152 kg | 127.0 cm | 54.0 cm | 37.1 |
cm
HWAM 3520c/3520m, soapstone cladding| 167/164 kg| 127.0 cm| 54.0 cm| 37.1 cm
Heat storage stones, HWAM 3520| 44 kg| | |
Floor plate
European, national and local regulations must be observed in terms of the size
and thickness of a non-combustible floor covering the floor in front of the
combustion chamber opening. Ask your HWAM retailer for assistance. The
combustion chamber opening is 34.0 cm wide.
Distance to combustible materials
Min. distances – uninsulated flue gas pipe (drawing A) | HWAM 3520 |
---|---|
1. Recommended for brick wall | 10 cm |
1. For combustible back wall | 14 cm |
2. For combustible side wall | 19.5 cm |
1.To combustible wall, corner installation, 45º | 10 cm |
3. Distance to furnishings in front | 100 cm |
5. For combustible wall, side, in front of the stove | 40 cm |
Min. distances – insulated flue gas pipe (drawing A) | HWAM 3520 |
--- | --- |
1. Recommended for brick wall | 10 cm |
1. For combustible back wall | 11.5 cm |
2. For combustible side wall | 19.5 cm |
1.To combustible wall, corner installation, 45º | 10 cm |
3. Distance to furnishings in front | 100 cm |
5. For combustible wall, side, in front of the stove | 40 cm |
Remember to pay attention to the applicable regulations concerning the
required distance between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM®
SmartControl™.
Please be aware that not all glass parts are heat-resistant. For this reason,
a glass wall should sometimes be treated as a combustible wall, in which case
we ask you to contact your local chimney sweep or glass producer to hear at
what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke
nuisance. As a general rule, satisfactory draught conditions are achieved if
the chimney is 4 m above the stove and at least 80 cm above the ridge. If the
chimney is placed at side walls, the top of the chimney should always be
higher than the ridge or the tallest point of the roof. Always be aware of any
national and/or local regulations applying to thatched roofs and the location
of the chimneys.
The stove requires a minimum draught of 11 Pa (measured at EN 13240
measurement point). If measured just above the smoke flue socket, the chimney
draught must be 17-19 Pa. The chimney must have a minimum clearing of Ø 150
mm. The chimney must be provided with an easily accessible cleaning door. The
chimney and flue duct must be of flue class T400 and be CE marked.
Furthermore, it must have obtained the classification of G in soot fire
testing. The required distance to combustible material must be complied with
in accordance with the brand label. Ask your HWAM retailer for further
information.
Changing the smoke outlet from top outlet to back outlet – HWAM 3520
(drawing D)
For stoves suitable for stone cladding (without stone cladding installed),
begin with item 3 and end after item 16.
- Removing sides. Lift one side about 10 mm and pull it away from the stove so that it disen gages from the guide pins on the bottom plate of the stove. Repeat on the other side.
- Removing the top plate (1). Remove the four screws (Torx Bit no. 30 or M6 nut) beneath the top plate, two on each side, and lift the top plate off.
- Remove the front of the heat storage compartment (8). Loosen the two screws (9) on each side of the front of the heat storage compartment without removing them. Then pull the front forward.
- Removing the heat shield (7). Uninstall the heat shield on the outside of the rear plate by removing the three screws. The heat shield has a cut-out for the flue duct. Break off the pre-cut plate; the resulting hole fits the flue duct.
- Removing the rear plate (2). Lift the rear plate and pull it away from the stove so that it disen- gages from the guide pins on the bottom plate of the stove. There is a cut-out in the rear plate for the smoke outlet. Break off the plate within this cut-out to make a hole in the rear plate so there is room for the smoke outlet.
- Removing the cover plate (3). Remove the cover plate on the back of the stove by removing the three screws (Torx Bit no. 30).
- Open the metallic tabs (5) and take the wires out.
- Pull the lambda sensor coupling (10) free of the wire fastener (11).
- Remove the temperature monitor from the smoke ring.
- Remove the flue ring (4) and fasten it to the rear of the stove. NB: Remember to turn the lambda probe (6) as illustrated in drawing D1.
- Reattach the temperature monitor in the smoke ring, leading the sensor about 3 cm into the smoke ring.
- Reposition the lambda sensor coupling (10) in the wire fastener (11).
- Fix the two wires by closing the metallic tabs (5) again.
- Installing the rear plate (2). Place the rear plate on the guide pins at the back of the bottom plate of the stove; then press it in towards the stove. Lift the rear plate and press it lightly inwards until it engages with the guide pins.
- Installing a heat shield (7). Replace the heat shield at the back of the stove.
- Installing the front on the heat storage compartment (8). Place the front on the heat storage compartment and fasten with the four screws (9).
- Installing the top plate of the stove (1). Place the top plate on the fittings and secure it with the four screws, two on each side.
- Installing sides. Put the sides on the guide pins in the bottom plate of the stove and press them in towards the stove. Lift the sides and press them lightly inwards until they engage with the guide pins.
An accessory top flue blanking plate is available to cover the hole in the
stove top plate if the smoke outlet is connected at the rear of the stove.
Connection to chimney
All the stoves have both back and top smoke outlet that can be connected to an
approved steel chimney on top or directly out at the back to a chimney.
Make sure that the chimney is tight and that no false draft is caused around
neither the cover plate, in connection with a covered smoke outlet, nor the
cleanout door and pipe connections. Please note that bent and/or horizontal
smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawing B and C)
B: Top outlet
C: Back outlet
- Steel chimney (9).
- Flue gas elbow (10). Fits into smoke flue socket.
- Brick-built jamb of flue (11).
- Built-in pipe sleeve (12). Fits smoke flue.
- Wall rosette (13). Covers disruption to wall around pipe sleeve.
- Joint (14). Sealed with packing material.
- Smoke outlets (15) of the HWAM stove.
- Smoke flue regulating damper (16).
- Soot door (17).
Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted
correctly. Check that all insulation plates of the combustion chamber have
been properly placed, i.e. that the bottom plate is horizontal and that the
side plates are vertical and reach all the way up to the steel sides of the
combustion chamber and down to the bottom plate.
Vertical cross-section of the stoves (Drawing B):
- The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides.
- Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The two halves join in the holders behind the air pipe. Once the stove has been installed, twist the protection off the two hooks by using pliers or a screwdriver.
- Removable rear plate (2a). This must always be mounted if the stove is placed next to a combustible wall.
- Removable heat shield (2b) – HWAM 3520. This must always be mounted if the stove is placed next to a combustible wall.
- Loose heat shield (8) under the ash pan. This can be used as a lid when the ash pan is removed for emptying. This must always be mounted when the stove is burning
Connection of the HWAM® SmartControl™
Before using the stove it must be connected to power. See the instructions in
the separate manuals for the app IHS
SmartControl™ or in the Quickguide in order to connect to stove with the app
and the wireless room temperature sensor.
Chimney
The chimney is the “engine” of the stove and it is crucial for the functioning
of the woodburning stove. The chimney draft provides a partial vacuum in the
stove. This vacuum removes the smoke from the stove, sucks air through the
dampers in the Airbox for the so-called glass pane rinse which keeps the glass
free of soot, and for the combustion.
The chimney draft is created by the differences in temperature inside and
outside the chimney. The higher the temperature within the chimney, the
greater the draft (a brick chimney takes longer to warm up than a steel
chimney). On days where the weather and wind conditions create insufficient
draught inside the
chimney, it is even more important to warm up the chimney as quickly as
possible. The trick is to quickly get some flames going. Split the wood into
extra fine pieces, use an extra firelighter, etc.
If the stove has not been used for a longer period, it is important to check
that the chimney pipe is not blocked. It is possible to connect several
devices to the same chimney.
However, it is important to first check the applicable rules.
Chimney sweeping
To prevent the risk of chimney fires, the chimney must be cleaned every year.
The flue duct and the smoke chamber above the baffle plate must be cleaned
together with the chimney. If the chimney is too tall to be cleaned from
above, it must be equipped with a soot door. In case of a chimney fire and
overheating, the HWAM® SmartControl™ will enter a security mode and
automatically adjust all dampers in the Airbox, effectively quenching the
fire. Do not open the door for the burning chamber, since that might cause the
fire to rekindle. Contact the fire brigade. After a fire, the stove should be
checked by a chimney sweep before use.
Firing manual – wood
Your first heating session
The lacquer will be fully hardened after the stove has been used, and the door
and the ash pan should be opened very carefully as there will otherwise be a
risk that the gaskets will stick to the lacquer. In addition the lacquer may
initially give off an unpleasant odour, so make sure that the room is well
ventilated.
Tips about fuel
Approved fuel types
The wood burning stove is EN approved for combustion of wood only. It is
recommended to use dried chopped wood with a water content of 12-18%. Stoking
a fire with wet wood results in soot, environmental problems, and a less
efficient fuel economy.
Recommended wood types
All types of wood, for instance birch, beech, oak, elm, ash, conifers, and
fruit trees can be used as fuel in your insert. The great difference is not in
the fuel value, but in the weight of the wood types per cubic metre. Beech
weighs more per m³ of wood than common spruce, for instance. This is why more
common spruce is required, in terms of volume, to obtain an amount of heat
similar to that of beech. Heavy types of wood such as ash, beech, oak and elm
are generally not that easy to light up. In addition, they burn more slowly
and give off more embers. Light types of wood such as birch, maple, spruce and
pine are more easy to light up. They burn faster and give off fewer ambers.
You may therefore take advantage of the light types of wood for lighting and
use the heavier types of wood to ensure a longer burning time.
Banned fuel types
It is not allowed to stoke a fire with the following: printed matter, plywood,
plastic, rubber, fluid fuels, and rubbish such as milk cartons, lacquered wood
or impregnated wood and fossil fuels. The reason that you should not apply any
of the above is that during combustion they develop substances that are health
hazardous and harmful to the environment. These substances could also damage
your wood burning stove and chimney, rendering the product warranty void.
Storage of wood
A moisture content of 12-18% is achieved by storing recently felled wood
outdoors under a leanto for at least one year, preferably 2 years. Wood stored
indoors has a tendency to become too dry and combust too quickly. However, it
might be advantageous to store fuel for lighting a fire indoors for a few days
prior to use.
It is recommended to purchase a wood moisture meter to continuously check that
the firewood has the correct moisture content before using it for firing.
Split the wood and measure the moisture content of the split surfaces.
Recommended dimensions
The dimensions of the fuel are important to good combustion. The dimensions
should be as follows:
Fuel type | Length in cm | Diameter in cm |
---|---|---|
Wood for kindling a fire (finely chopped) | 25-30 | 2-5 |
Chopped wood | 25-30 | 7-9 |
Special lighting guide for wood-burning stoves with stone cladding
Stones are a natural product that must be allowed to adapt to fluctuations in
temperature. We recommend following the procedure below:
-
The First Stoking
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment. Place 5-8 pieces of kindling randomly on top. Place two firelighters in between the top layers of kindling. Light up the firelighters and close the stove door. Set the temperature level to level 1. Let the fire burn out and do not restoke even if there is a restoking alarm. When the fire has died out completely, the door must be opened and stay open while the stove cools down to room temperature. -
The Second Stoking
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment. Place 5-8 pieces of kindling randomly on top. Place two firelighters in between the top layers of kindling. Light up the fire-lighters and close the stove door. Set the temperature level to level 2. When there is a restoking alarm, you should restoke. Put at least two pieces of wood into the stove, weighing up to 1 kg each. Let the fire burn and let the stove cool down to room temperature before the next lighting. -
The Third Stoking
Repeat the second stoking. Set the temperature level to level 3. Let the fire burn and allow the stove to cool down after the fire has died out.
Restoking:
Follow the general instructions, see the sections “Lighting up” and “Stoking”.
Lighting Up
A successful combustion process requires that the wood is lit in the right
way. A cold stove and a cold chimney challenge the combustion process. Be
careful to make a good lighting with suitably dry wood, using kindling and
lighting the fire in the top layers of kindling. It is important to achieve a
high flue gas temperature quickly.
Open the door. Place two pieces of wood (5-8 cm in diameter) horizontally in
the bottom of the combustion compartment. Place 5-8 pieces of kindling
randomly on top. Place two fire-lighters in between the top layers of
kindling. Light up the fire-lighters and close the stove door. Select the
desired room temperature level.
As soon as the door is opened the HWAM® SmartControl™ is activated. If
lighting up does not occur within 15 minutes, the HWAM® SmartControl™ will
automatically go back to standby and the dampers in the Airbox will be closed.
If the smoke temperature does not reach a high enough level after lightning or
stoking, the app IHS Smart Control™ and the wireless room temperature sensor
emit a restoking alarm, even if there is still unburned wood and flames in the
combustion chamber. The restoking alarm is emitted to make you aware that the
fire needs more energy. Restoking with small pieces of kindling wood can often
provide a more rapid and sufficient temperature rise.
The HWAM ® SmartControl TM closes all three air dampers in the Airbox when the
stove is in standby mode. This prevents hot air from the room to enter the
chimney (heat loss). This might on the other hand result in a very cold
chimney when the stove is lit. In certain cases it is necessary to assist the
draught in the chimney by opening the door to the burn- ing chamber 3-5
minutes before lightning the stove. Read more on
www.hwam.com about the function of the chimney.
Important!
The ash pit must not be opened when lighting up. It must always be closed when
the stove is in use. Otherwise the HWAM® SmartControl™ does not function. The
door should only be opened when lighting up, when restoking, and when cleaning
the stove. Never leave a stove before there are lasting flames in the wood
after firing!
The Thermostat Function
The HWAM® SmartControl™ will in general have an environmentally friendly
combustion and adapt to the desired room temperature. The thermostat function
is designed as a radiator valve. The user enters a desired heat level, which
suits the room in which the stove is installed. When the thermostat is set at
a heat level, the control function will adapt to this temperature.
- If the room temperature is lower than the desired heat level, the HWAM® SmartControl™ increases the flue gas temperature in order to increase the radiant heat from the stove.
- If the room temperature is higher than the desired heat level, the HWAM® SmartControl™ decreases the flue gas temperature, thereby giving the layer of embers as long a life as possible before restoking. This will reduce the heat radiation from the stove and facilitate restoking without having to light up the fire anew. If the room temperature drops below the desired level, the ember phase will be shortened, and the HWAM® SmartControl™ will activate a restoking alarm. The HWAM® SmartControl™ will signal that a restoking is due at the flue gas temperature of 180° C, and at 100° C the HWAM® SmartControl™ will enter standby mode and all dampers will close.
- Should the room temperature be much lower than the desired heat level, the HWAM® SmartControl™ increases the flue gas temperature. If a satisfactory increase in temperature does not occur, the control will activate a restoking alarm, since it expects that more wood is needed to increase the heat level in the room.
- If the room temperature after a new restoking still does not reach the desired level, the water content in the firewood may be too high or the draught in the chimney too weak. The HWAM® SmartControl™ always strives for a sufficiently high flue gas temperature to ensure an environmentally friendly combustion.
Stoking
When alarm for restoking sounds the stove is ready for restoking. The alarm
for restoking will come via the room temperature sensor or the acquired remote
control. The app IHS Smart Control™ will also come with a notification that it
is time for restoking if the app is opened. For more information on the app,
see details in separate manuals for the app IHS Smart Control™or in the
Quickguide.
The amount of wood that is used for restoking should be adjusted based on the
current heat demand. In terms of combustion technique, you should always stoke
the stove with at least two pieces of wood at a time even if you only use a
small amount of wood. You can also choose not to restoke. After a while the
stove will then automatically go in stand-by mode.
During combustion, the outer surfaces of the stove will become hot, and due
care must therefore be shown.
Cleaning the glass
We recommend wiping the glass after a fire. This is best done using a paper
towel.
Fuelling with coal or pet coke
The stove is not approved to use coal or pet coke as a fuel.
Operating the heat compartment damper – HWAM 3520
There is a damper at the back of the stove between the top plate and the
heat compartment that opens and closes the flow of convection air in the heat
compartment. The supply of convection air can be opened by moving the damper
to the left and closed by moving the damper to the right. We recommend that
the convection damper is kept closed when fuelling the stove in order to heat
up and thereby store heat in the heat storage stones in the heat compartment
as rapidly as possible. Keeping the convection damper closed retains the heat
stored in the heat storage stones as long as possible. When the damper is
opened, the heat from the heat storage stones in the heat compartment will
rapidly be transferred to the room.
Firing in general
Rapid or fierce heat
Rapid or fierce heat is obtained by burning many small pieces of wood.
Maximum amounts of fuel:
The maximum allowed amount of fuel per hour is:
Wood: 1.46 kg
If these limits are exceeded, the stove will no longer be covered by the
factory guarantee, and it may also become damaged due to excessive heat, the
glass may turn white, for example. If the flue gas temperature exceeds 580° C,
the HWAM® SmartControl™ will revert to safety adjustments and automatically
turn down the air valves to avoid overheating. When the temperature is reduced
to 450º C, the normal functions apply again. The stove has been approved for
intermittent use.
Typical re-firing interval
Typical re-firing interval at nominal performance
Wood: 47 min (1.1 kg)
Prolonged burning time
You achieve the slowest combustion by setting the desired room temperature at
level 0. At this level the combustion takes place with the lowest possible
flue gas temperature and the ember phase will be drawn out as long as
possible.
How to achieve the best combustion
The HWAM® SmartControl™ is purposely designed to generate the cleanest and the
most economical combustion. A good combustion is achieved when the fire gets
the right amount of oxygen supply at the right time and place in the
combustion chamber. The HWAM® SmartControl™ allows for variations in external
circumstances. Nevertheless, it is important to use clean and dry wood
(humidity approx. 12-18%). Read more on
www.hwam.com.
Maintenance
Cleaning
Any maintenance of the stove should only be carried out when it is cold. Daily
maintenance is limited to vacuum cleaning the stove externally, using the soft
brush attachment. You can also dust the stove using a dry, soft cloth or
brush. But remember, only when the stove is cold. Do not use water, spirit or
any other kind of cleaner, as this will damage the lacquer.
Once a year, the stove should be thoroughly serviced. The combustion chamber
should be cleared of ashes and soot. The hinges and the closing hook must be
greased with liquid copper fat spray (heat-resistant up to 1100°C), see
drawing F. Lift the door approx. ½ cm and spray copper fat onto the hinge
leaf.
Service inspection
Your stove should be given a thorough, preventive inspection once every two
years. This includes:
- Thorough cleaning of the stove.
- Checking gaskets. Replace gaskets if they are not intact or have softened.
- Checking of heat insulating material and possibly replacement.
- Checking of the bottom/shaking grate.
- Use copper grease for hinges and locking hooks (see drawing F).
All service checks must be performed by an authorised fitter. Use only
original spare parts.
Inside Cleaning
Unless the safety fittings for transportation have not already been removed,
twist the safety fittings for transportation off the two hooks by using pliers
or a screwdriver. The smoke shelf and baffle plate is to be removed from the
stove before cleaning (Drawing E):
- First lift the smoke shelf (1) out of the steel rail (2) at the back of the combustion chamber. Next, lower it beneath the holders (3) and slide it out.
- Lift each half of the steel smoke plate (4) off the holder (5) behind the smoke pipe, and remove them from the hook (6) beneath the top plate.
Ashes
The ash pan is best emptied by pulling a waste bag over the pan, tipping it
and then carefully pulling it out of the bag. Ashes are disposed of via the
domestic waste collection.
Please note that there may be embers in the ashes for up to 24 hours after the
fire has gone out!
Insulation
The efficient, but porous insulation of the combustion chamber may, in time,
be worn and damaged. Cracks in the insulation are irrelevant to the efficiency
of the stove. However, it should be replaced, if there are actual holes due to
parts of the lining falling off or when, due to wear and tear, it has been
reduced to less than half its original thickness.
Door/glass
A sooty glass door can easily be cleaned with a piece of moist kitchen roll
dipped in ash. Go about it in vertical movements (up and down). Follow up with
a dry piece of kitchen roll.
Seals
Check frequently to ensure that seals in the door and ash pan are intact and
not brittle. Failing this, they should be replaced. Use original seals only.
Surface
Usually, it is not necessary to any treatment to the painted surfaces of the
wood-burning stove. Any damage to the paint may, however, be remedied with
spray paint, which can be bought from your stove retailer.
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
Maintenance Alarms
If a maintenance alarm goes off, you can continue using the wood-burning
stove, but contact your retailer as soon as possible. Your stove could be
affected by impure combustion.
Operational problems
Blackened glass
- The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture level not exceeding 12-18 % RH.
- Faulty seal in door. Fit new seal.
Smoke in the room when opening door
- The grate in the chimney may be closed. Open the grate.
- Insufficient chimney draft. See section on chimney or contact chimney sweep.
- Soot door leaking or dislodged. Replace or refit.
- Never open the door when there are still flames on the wood.
Uncontrollable combustion
- Faulty seal in door or ash pan. Fit new seal.
Safety Alarms
In case the safety alarms go off, you must not use the stove. Contact your
retailer as soon as possible.
At interruptions that you cannot yourself rectify, you should contact the
retailer.
Declaration of Performance
The DoP can be downloaded from our website via the following links:
www.hwam.com/dop/3500_ihs_g22
Product information on solid fuel local space heaters according to
Comission regulation (EU) 2015/1185
Model | HWAM 3520 |
---|---|
Direct heat output [kW] | 4,8 |
Indirect heating functionality | No |
Indirect heat output [kW] | – |
Type of heat output/room temperature control | Two ore more manual |
stages, no temperature control
Space heating performance at nominal heat output
Fuel| Preferred fuel| Seasonal space heating energy efficiency
[%]
Wood logs with moisture content 12-18 %| Yes| 105
Emissions| mg/m 3 (13% O₂)
Particulate matter (PM)| 906
Organic gaseous compounds (OGC)|
Carbon monoxide (CO)| 0
Nitrogen oxides (NOₓ)| 13
Characteristics when operating with the prefered fuel only
Nominal heat output [kW]|
Electric power consumption nominal heat output [kW]| –
Electric power consumption minimum heat output [kW]| –
Electric power consumption standby mode [kW]| –
Useful efficiency at nominal heat output [%]| –
Energy efficiency index|
Energy efficiency class|
Specific Precautions during Assembling, Installing & Maintenance:
See installation instructions for more information
Product End-of-Life/Recycling:
To dispose of the stove after the product life has expired, please observe the
following information
- Dispose of the items correctly i.e. separate the parts to be disposed of in material groups
- Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling and disposal technology
HWAM A/S
Nydamsvej 53
DK-8362 Hørning www.hwam.com
Documents / Resources
| Hwam
3520 Wood Burning
Stove
[pdf] User Manual
3520 Wood Burning Stove, 3520, Wood Burning Stove, Burning Stove, Stove
---|---
| Hwam
3520 Wood Burning
Stove
[pdf] User Manual
3520 Wood Burning Stove, 3520, Wood Burning Stove, Burning Stove, Stove
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>