For UK – The Clean air aCT 1993 and SmoKe ConTrol areaS
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offense to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area. It is also an offense to acquire an ” unauthorized fuel” for use within a smoke control area unless it is used in an ”exempt” appliance (”exempted” from the controls which generally apply in the Smoke Control Area).
In England, appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are exempted from publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture, Environment and Rural Affairs under Section
16 of the Environmental Better Regulation Act (Northern Ireland) 2016. In Wales, these are Exempted by regulations made by Welsh Ministers.
Further information on the requirements of the Clean Air Act can be found here: https://www.gov.uk/ smoke-control-area-rules. Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of Smoke Control Areas and you can contact them for details of Clean Air Act requirements.
The HWAM 4300 stoves detailed below have been recommended as suitable for use in smoke control areas when burning wood logs. The appliance has been fitted with modified secondary air control to prevent the closure of the air inlet below 25 %. Appliances recommended as suitable for use in Smoke Control Areas :

  • HWAM 4340 IHS
  • HWAM 4340 IHS with soapstone cladding,
  • HWAM 4340 IHS with natural stone cladding

Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emissions can occur. Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
Fuel overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke.
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open except as directed in the instructions.

HWam® SmarTConTrol™

Congratulations on your new wood-burning stove complete with an HWAM ® SmartControl TM We are pleased that you have chosen a HWAM wood-burning stove and confident that it will give you much pleasure. The HWAM ® SmartControl TM is a digital control of the combustion in your new wood-burning stove. The purpose of the HWAM ® SmartControl TM is to control the combustion in an environmentally optimal and economically efficient way, with a view to generating greater user comfort. The HWAM ® SmartControl TM is a new patented technology, which electronically adjusts the air supply to the combustion chamber. Your new wood-burning stove continually measures the temperature and the oxygen levels of the combustion. Moreover, it is programmed to supply oxygen to the fire through three important air inlets in the right amount, and at the right time and place in the combustion chamber. By downloading a free app for your smartphone or tablet, you can use the app among other things: to set the thermostat to the desired room temperature level, choose time for night-time reduction and keep your stove updated. The app also gives you current information on burning in the stove. See details in separate manuals for the app IHS Smart Control TM or in the Quickguide. . Your new wood-burning stove and the HWAM ® SmartControl TM will ensure the cleanest possible combustion as well as a good fuel economy, regardless of external conditions such as the type of firewood used, the chimney, the user’s experience, and other external circumstances.
The HWAM ® SmartControl TM consists of the following components:

  • Air box: the Air box contains a printed circuit board/software, as well as three motors and dampers that control primary, secondary, and tertiary combustion air. The fresh air system can be mounted on the Air box to the back or in the bottom.
  • Two sensors: a temperature sensor and an oxygen sensor transmit information from the woodburning stove to the Airbox.
  • Room temperature sensor: The room temperature sensor with batteries communicates with the HWAM ® SmartControl TM via a wireless connection. It should be placed so it does not have the direct radiant heat from the stove. Note that the maximum distance between stove and room temperature indicator is about 4-5 metres. The range is reduced if there are walls or other obstructions between the stove and the room temperature indicator.
  • Electricity supply: from the Air box to the nearest wall socket.
  • App “IHS Smart Control TM:The app can be downloaded free from the App Store or Google Play Store. See details in separate manuals for the app IHS Smart Control TM or in the Quickguide. .

Installation

In general
To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorized HWAM retailer or a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under “Retailer locations”.
Safety
The installation of your HWAM woodburning stove must always comply with all European, national, and local building regulations. The installation must be carried out in accordance with the instructions in the installation and user manuals and subsequently registered with the local authorities. Upon installation, the chimney sweep must approve the installation before you can start using the woodburning stove. All HWAM woodburning stove packaging material must be handled in accordance with local waste management regulations.
Room requirements
Always ensure a supply of fresh combustion air to the room where the stove is to be installed. The wood burning stove uses approx. 7-20 m 3 of air per hour. A window that can be opened or an adjustable air valve will be sufficient. It must not be possible to block the adjustable air valve/grate. In newly built/ airtight dwellings, we recommend that a fresh air system should be installed for the direct supply of external air to the combustion. This fresh-air system may be bought separately. Before installing the stove, you must ensure that the load-bearing capacity of the floor can withstand the weight of the stove and the chimney. The weight of the chimney should be calculated according to its
dimensions and height. Remember to consider that the stove must be connected to power.

Technical measures and data

Test results from nominal test EN 13240


Nominal heating effect| 6,0 kW
Flue gas temperature EN 13240 measurement point| 267ºC
Flue gas temperature measured in the outlet socket| 321ºC
Exhaust gas flow| 4,7 g/s
Efficiency| 82 %
Annual efficiency (EcoDesign)| 72 %
PM| 28 mg/m3
OGC| 75 mg/m3
NOx| 113 mg/m3
CO at 13% O2| 1250 mg/m3
CO at 13% O2| 0,10 %
Energy efficiency index| 109
Energy efficiency class| A+
Test result based on NS 3058|
Particle emissions| 1,16 g/kg

The declaration of performance (DoP) can be downloaded from our website, www.hwam.com.

Model Weight Height Width Depth
HWAM 4340 140 kg 120,3 cm 58,7 cm 47,9 cm
HWAM 4340 with natural stone cladding 198 kg 124,5 cm 58,7 cm 47,9 cm
HWAM 4340 with soapstone cladding 227 kg 124,5 cm 58,7 cm 47,9 cm

Floor plate
European, national and local regulations must be observed in terms of the size and thickness of a noncombustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM retailer for assistance. The combustion chamber opening is 38.2 cm wide. Distance to combustible materials

Min. distances – uninsulated flue gas pipe (drawing A) HWAM 4340
1. Recommended for brick wall 10 cm
1. For the combustible back wall 11 cm
2. For combustible side wall 25 cm
1.To the combustible wall, corner installation, 45º 13 cm
3. Distance to furnishings in front 120 cm

Remember to pay attention to applicable regulations concerning the required distance between the wall and smoke pipe.
It is recommended to have 10 cm distance to a brick wall back and side to facilitate the servicing of the HWAM® SmartControl™.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should sometimes be treated as a combustible wall, in which case we ask you to contact your local chimney sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sufficient draught and prevent any smoke nuisance. As a general rule, satisfactory draught conditions are achieved if the chimney is 4 m above the stove and at least 80 cm above the ridge. If the chimney is placed at side walls, the top of the chimney should always be higher than the ridge or the tallest point of the roof. Always be aware of any national and/or local regulations applying to thatched roofs and the location of the chimneys.
The stove requires a minimum draught of 12 Pa (measured at EN 13240 measurement point). If measured just above the smoke flue socket, the chimney draught must be 18-20 Pa.
The chimney must have a minimum clearing of Ø 150 mm. The chimney must be provided with an easily accessible cleaning door. The chimney and flue duct must be of flue class T400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer for further information.
Connection to chimney
All the stoves have both back and top outlets that can be connected to an approved steel chimney on top or directly out at the ear to a chimney.
Make sure that the chimney is tight and that no false draft is caused around neither the cover plate, in connection with a covered smoke outlet, nor the cleanout door and pipe connections. Please note that bent and/or horizontal smoke pipes will reduce the effect of the chimney draft.
Vertical cross-section of smoke flue (Drawings B and C)
B: Top outlet
C: Back outlet

  • Steel chimney (9).
  • Flue gas elbow (10). Fits into the smoke flue socket.
  • Brick-built jamb of flue (11).
  • Built-in pipe sleeve (12). Fits smoke flue.
  • Wall rosette (13). Covers disruption to wall around pipe sleeve.
  • Joint (14). Sealed with packing material.
  • Smoke outlets (15) of the HWAM stove.
  • Smoke flue regulating damper (16).
  • Soot door (17).

Fitting the loose parts
Before the stove is installed, you must ensure that all loose parts are fitted correctly. Check that all insulation plates of the combustion chamber have been properly placed, i.e. that the bottom plate is horizontal and that the side plates are vertical and reach all the  way up to the steel sides of the combustion chamber anddown to the bottom plate.
Vertical cross-section of the stoves (Drawing B, C and D):

  • The smoke shelf (5). To be placed on top of the steel rail and on the holders in the sides
  • Two-piece smoke defector plate (6). Each half is hung on the hooks located beneath the top plate. The two halves join in the holders (7a) behind the air pipe. Once the stove has been installed, remove the safety fittings for transportation (7b) from the two hooks
  • Rear plate (2a), covering HWAM ® Autopilot™. This must always be mounted if the stove is placed next to a combustible wall
  • Loose heat shield (8) under the ash pan. This can be used as a lid when the ash pan is removed for emptying. This must always be mounted when the stove ist burning

Connection of the HWAM ® SmartControl TM
Before using the stove it must be connected to power. See the instructions in the separate manuals for the app IHS SmartControl TM or in the Quickguide in order to connect to the stove with the app and the wireless room temperature sensor.
Chimney
The chimney is the “engine” of the stove and it is crucial for the functioning of the woodburning stove. The chimney draft provides a partial vacuum in the stove. This vacuum removes the smoke from the stove, sucks air through the dampers in the Air box for the so-called glass pane rinse which keeps the glass free of soot, and for combustion. The chimney draft is created by the differences in temperature inside and outside the chimney. The higher the temperature within the chimney, the greater the draft. It is therefore crucial that the chimney is heated well through before regulating the air supply and thus limiting the combustion in the stove (a brick chimney takes longer to warm up than a steel chimney). On days where the weather and wind conditions create insufficient draught inside the chimney, it is even more important to warm up the chimney as quickly as possible. The trick is to quickly get some flames going. Split the wood into extra fine pieces, use an extra firelighter, etc. If the stove has not been used for a longer period, it is important to check that the chimney pipe is not blocked. It is possible to connect several devices to the same chimney. However, it is important to first check the applicable rules.
Chimney sweeping
To prevent the risk of chimney fires, the chimney must be cleaned every year. The flue duct and the smoke chamber above the baffle plate must be cleaned together with the chimney. If the chimney is too tall to be cleaned from above, it must be equipped with a soot door. In case of a chimney fire and overheating, the HWAM ® SmartControl TM
will enter a security mode and automatically adjust all dampers in the Air box, effectively quenching the fire. Do not open the door for the burning chamber, since that might cause the fire to rekindle. Contact the fire brigade. After a fire, the stove should be checked by a chimney sweep before use.

Firing Manual – Wood

Your first heating session
The lacquer will be fully hardened after the stove has been used, and the door and the ash pan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addition, the lacquer may initially give off an unpleasant odor, so make sure that the room is well ventilated.
Tips about fuel
Approved fuel types
The wood-burning stove is EN approved for combustion of wood only. It is recommended to use dried chopped wood with a water content of 12-18%. Stoking a fire with wet wood results in soot, environmental problems, and a less efficient fuel economy.
Recommended wood types
All types of wood, for instance, birch, beech, oak, elm, ash, conifers, and fruit trees can be used as fuel in your insert. The great difference is not in the fuel value but in the weight of the wood types per cubic meter. Beech weighs more per m 3 of wood than common spruce, for instance. This is why more common spruce is required, in terms of volume, to obtain an amount of heat similar to that of beech. Heavy types of wood such as ash, beech, oak and elm are generally not that easy to light up. In addition, they burn more slowly and give off more embers. Light types of wood such as birch, maple, spruce and pine are easier to light up. They burn faster and give off fewer ambers. You may therefore take advantage of the light types of wood for lighting and use the heavier types of wood to ensure a longer burning time.
Banned fuel types
It is not allowed to stoke a fire with the following: printed matter, plywood, plastic, rubber, fluid fuels, and rubbish such as milk cartons, lacquered wood or impregnated wood and fossil fuels. The reason that you should not apply any of the above is that during combustion they develop substances that are health hazardous and harmful to the environment. These substances could also damage your wood-burning stove and chimney, rendering the product warranty void.
Storage of wood
The moisture content of 12-18% is achieved by storing recently felled wood outdoors under a lean-to for at least one year, preferably 2 years. Wood stored indoors has a tendency to become too dry and combust too quickly. However, it might be advantageous to store the fuel for lighting a fire indoors for a few days prior to use.
It is recommended to purchase a wood moisture meter to continuously check that the firewood has the correct moisture content before using it for firing. Split the wood and measure the moisture content of the split surfaces.
Recommended dimensions
The dimensions of the fuel are important to good combustion. The dimensions should be as follows:

Fuel type Length in cm Diameter in cm
Wood for kindling a fire (finely chopped) 30 2-5
Chopped wood 30 5-8

Special fire lighting guide for stoves with soapstone or natural stone cladding
Stones are natural products that need to adjust to temperature changes. We recommend following the procedure below:

  1. First stoking (drawing F)
    Open the door. Place 2 pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment (corresponding to 1-2 kg). Place 5-8 pieces of kindling randomly on top. Place 2 firelighters between the top layer of kindling. Light up the firelighters and close the door. Set the temperature level to level 1. Let the fire burn out and do not restoke even if there is a restocking alarm. When the fire has died out completely, the door must be opened and stay open while the stove cools down to room temperature.

  2. Second stoking
    Open the door. Place 2 pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment (corresponding to 1-2 kg). Place 5-8 pieces of kindling randomly on top. Place 2 firelighters between the top layer of kindling. Light up the firelighters and close the door. Set the temperature level to level 2. When there is a restocking alarm, you should restoke. Carefully open the door to prevent smoke and embers from escaping. Put at least 2 pieces of wood into the stove, weighing up to 1 kg each with a diameter of about 7-9 cm. Allow the fire to burn and let the stove cool to room temperature before stoking again.

  3. Third stoking
    Repeat the procedure for the second stoking, Set the temperature level to level 3. Allow the fire to burn and let the stove cool to room temperature after the fire has gone out.
    Restoking: Follow the general instructions, see the sections “Lighting the stove” and “Stoking”.
    Lighting the stove (drawing F)
    A successful combustion process requires that the wood is lit in the right way. A cold stove and a cold chimney challenge the combustion process. Be careful to make good lighting with suitably dry wood, using kindling and lighting the fire in the top layers of kindling. It is important to achieve a high flue gas temperature quickly. Push the air control lever (1) to the middle position. In case of a poor chimney draft push the air control lever all the way to the right.
    Push the shaking grate lever (2) all the way in so that the shaking grate is closed..
    Open the door. Place 2 pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment (corresponding to 1-2 kg). Place 5-8 pieces of kindling randomly on top. Place 2 firelighters between the top layer of kindling. Light up the fire-lighters and close the door. Select the desired room temperature level. As soon as the door is opened the HWAM ® SmartControl TM is activated. If lighting up does not occur within 15 minutes, the HWAM ® SmartControl TM will automatically go back to standby and the dampers in the Air box will be closed.

If the smoke temperature does not reach a high enough level after lightning or stoking, the app IHS Smart Control TM and the wireless room temperature sensor emit a restoking alarm, even if there is still unburned wood and flames in the combustion chamber. The restoking alarm is emitted to make you aware that the fire needs more energy. Restoking with small pieces of kindling wood can often provide a more rapid and sufficient temperature rise. The HWAM ® SmartControl TM closes all three air dampers in the Air box when the stove is in standby mode. This prevents hot air from the room to enter the chimney (heat loss). This might on the other hand results in a very cold chimney when the stove is lit. In certain cases it is necessary to assist the draught in the chimney by opening the door to the burning chamber 3-5 minutes before lighting the stove. Read more on www.hwam.com about the function of the chimney.
Booster
Pull out the shaking grate lever (2) completely to activate the booster if the wood does not burn easily due to poor chimney draft.
IMPORTANT: For safety reasons, it may only be used during the first 3 minutes. As soon as the temperature in the combustion chamber is high enough and the draft in the chimney sufficient, push the lever all the way back in again. This ensures safe and efficient combustion. It reactivates the air wash system and avoids overheating of the stove. The booster is intended solely to assist in the event of poor draft during the first 3 minutes of the lighting process. A chimney draft of 12 Pa does not require the use of the booster. Important! The ash pit must not be opened when lighting up. It must always be closed when the stove is in use. Otherwise, the HWAM ® SmartControl TM does not function. The door should only be opened when lighting up, when restoking, and when cleaning the stove. Never leave a stove before there are lasting flames in the wood after firing!
The Thermostat Function
The HWAM ® SmartControl TM will in general have environmentally friendly combustion and adapt to the desired room temperature. The thermostat function is designed as a radiator valve. The user enters the desired heat level, which suits the room in which the stove is installed. When the thermostat is set at a heat level, the control function will adapt to this temperature.

  • If the room temperature is lower than the desired heat level, the HWAM ® SmartControl TM increases the flue gas temperature in order to increase the heat radiation from the stove.
  • If the room temperature is higher than the desired heat level, the HWAM ® SmartControl TM decreases the flue gas temperature, thereby giving the layer of embers as long a life as possible before restoking. This will reduce the heat radiation from the stove and facilitate restoking without having to light up the fire anew. If the room temperature drops below the desired level, the ember phase will be shortened, and the HWAM ® SmartControl TM will activate a restoking alarm. The HWAM ® SmartControl TM will signal that a restoking is due at the flue gas temperature of 180° C, and at 100° C the HWAM ® SmartControl TM will enter standby mode and all dampers will close.
  • Should the room temperature be much lower than the desired heat level, the HWAM ® SmartControl TM increases the flue gas temperature. If a satisfactory increase in temperature does not occur, the control will activate a restoking alarm, since it expects that more wood is needed to increase the heat level in the room.
  • If the room temperature after a new restoking still does not reach the desired level, the water content in the firewood may be too high or the draught in the chimney too weak. The HWAM ® SmartControl TM always strives for a sufficiently high flue gas temperature to ensure environmentally friendly combustion.

Stoking
When the alarm for restoking sounds the stove is ready for restoking. The alarm for restoking will come via the room temperature sensor or the acquired remote control. The app IHS Smart Control TM will also come with a notification that it is time for restoking if the app is opened. For more information on the app, see details in separate manuals for the app IHS Smart Control TM or in the Quickguide.
The amount of wood that is used for restoking should be adjusted based on the current heat demand. In terms of combustion technique, you should always stoke the stove with at least two pieces of wood at a time even if you only use a small amount of wood. You can also choose not to restore. After a while, the stove will then automatically go in stand-by mode. During combustion, the outer surfaces of the stove will become hot, and due care must therefore be shown.
Cleaning the glass
We recommend wiping the glass after a fire. This is best done using a paper towel.
Fuelling with coal or pet coke
The stove is not approved to use coal or pet coke as a fuel.

Firing in general

Rapid or fierce heat
Rapid or fierce heat is obtained by burning many small pieces of wood.
Maximum amounts of fuel:
The maximum allowed amount of fuel per hour is:
Wood: 2.7 kg
If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also become damaged due to excessive heat, the glass may turn white, for example. If the flue gas temperature exceeds 580 o C, the HWAM ® SmartControl TM  will revert to safety adjustments and automatically turndown the air valves to avoid overheating. When the temperature is reduced to 450 o C, the normal functions apply again. The stove has been approved for intermittent use. Typical re-firing interval at nominel performance Wood: 45 min (1,23 kg)
Prolonged burning time
You achieve the slowest combustion by setting the desired room temperature at level 0. At this level the combustion takes place with the lowest possible flue gas temperature and the ember phase will be drawn out as long as possible. How to achieve the best combustion The HWAM ®  SmartControl TMis purposely designed to generate the cleanest and the most economical combustion. A good combustion is achieved when the fire gets the right amount of oxygen supply at the right time and place in the combustion chamber. The HWAM ®  SmartControlTM allows for variations in external circumstances. Nevertheless, it is important to use clean and dry wood (humidity approx. 12-18%). Read more on www.hwam.com.

Maintenance

Cleaning
Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a dry, soft cloth or brush. But remember, only when the stove is cold. Do not use water, spirit or any other kind of cleaner, as this will damage the lacquer.
Once a year, the stove should be thoroughly serviced. The combustion chamber should be cleared of ashes and soot. The hinges and the closing hook must be greased with liquid copper fat spray (heat-resistant up to 1100 °C), (drawing H). Lift the door approx. ½ cm and spray copper fat onto the hinge leaf. Service inspection
Your stove should be given a thorough, preventive inspection once every two years. This includes:

  • Thorough cleaning of the stove
  • Checking gaskets. Replace gaskets if they are not intact or have softened
  • Checking of heat insulating material and possibly replacement
  • Checking of the bottom/shaking grate
  • Use copper grease for hinges and locking hooks (drawing G)

All service checks must be performed by an authorized fitter. Use only original spare parts
Inside cleaning
Unless the safety fittings for transportation (2 split pins) have not already been removed, start by removing the split pins (drawing D).
The smoke shelf and baffle plate is to be  removed from the stove before cleaning

  • Lift the smoke shelf out of the steel rail at the back of the combustion chamber. Next, lower it beneath the holders and slide it out (drawing E1)
  • Lift each half of the steel smoke plate off the holder and remove them (drawing E2) After sweeping, reinstall the parts in the stove in reverse order.

Ashes
The ash pan is best emptied by pulling a waste bag over the pan, tipping it and then carefully pulling it out of the bag. Ashes are disposed of via the domestic waste collection.
Please note that there may be embers in the ashes for up to 24 hours after the fire has gone out!
Insulation
The efficient, but porous insulation of the combustion chamber may, in time, be worn and damaged. Cracks in the insulation are irrelevant to the efficiency of the stove. However, it should be replaced, if there are actual holes due to parts of the lining falling off or when, due to wear and tear, it has been reduced to less than half its original thickness.
Door/glass
A sooty glass door can easily be cleaned with a piece of moist kitchen roll dipped in ash. Go about it in vertical movements (up and down). Follow up with a dry piece of kitchen roll.
Seals
Check frequently to ensure that seals in the door and ash pan are intact and not brittle. Failing this, they should be replaced. Use original seals only.
Surface
Usually, it is not necessary to any treatment to the painted surfaces of the wood-burning stove. Any damage to the paint may, however, be remedied with spray paint, which can be bought from your stove retailer.
Guarantee
The guarantee does not cover damage due to insufficient maintenance!
Maintenance Alarms
If a maintenance alarm goes off, you can continue using the wood-burning stove, but contact your retailer as soon as possible. Your stove could be affected by impure combustion.

Operational problems

Blackened glass

  • The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture level of 12-18% RH
  • Faulty seal in door. Fit new seal Smoke in the room when opening door
  • The grate in the chimney may be closed. Open the grate
  • Insufficient chimney draft. See section on chimney or contact chimney sweep
  • Soot door leaking or dislodged. Replace or refit
  • Never open the door when there are still flames on the wood

Uncontrollable combustion

  • Faulty seal in door or ash pan. Fit new seal
  • If there is an excessive chimney draft, it may be necessary to push the air control lever all the way to the left. Also do this when the stove is not in use, the air control lever must be pushed all the way to the left

Safety Alarms
In case the safety alarms go off, you must not use the stove. Contact your retailer as soon as possible.
At interruptions that you cannot yourself rectify, you should contact the retailer.

DECLARATIONS  OF PERFORMANCE
The DoP can be downloaded from our website via the following links: www.hwam.com/dop/4300ihs 
Product information on solid fuel local space heaters according to Commission regulation (EU) 2015/1185

Model HWA 4340 IHS
Direct heat output [kW] 6,0
Indirect heating functionality No
Indirect heat output [kW]
Type of heat output/room temperature control With electronic room

temperature control
Space heating performance at nominal heat output

Fuel| Preferred fuel| Seasonal space heating energy efficiency [%]
Wood logs with moisture content 12-18 %| Yes| 72
Emissions| mg/m 3 (13% O )  2
Particulate matter (PM)| 28
Organic gaseous compounds (OGC)| 75
Carbon monoxide (CO)| 1250
Nitrogen oxides (NOₓ)| 113
Characteristics when operating with the prefered fuel only

Nominal heat output [kW]| 6,0
Electric power consumption nominal heat output [kW]| 0,015
Electric power consumption minimum heat output [kW]| 0,012
Electric power consumption standby mode [kW]| 0,0015
Useful efficiency at nominal heat output [%]| 82
Energy efficiency index| 109
Energy efficiency class| A+

Specific Precautions during Assembling, Installing & Maintenance: See installation instructions for more information
Product End-of-Life/Recycling:
To dispose of the stove after the product life has expired, please observe the following information

  • Dispose of the items correctly i.e. separate the parts to be disposed of in material groups
  • Always dispose of items in a way that is as sustainable as possible and that is in line with the current environmental protection, reprocessing/recycling, and disposal technology

HWAM A/S
Nydamsvej 53
DK-8362 Hørning
www.hwam.com