Sunair LPA-9600 1 Kilowatt Power Amplifier
The Sunair LPA-9500 and LPA-9600 are proven solutions in communications
applications where rugged and reliable high power amplifiers are required. The
amplifiers combine solid-state RF power amplification and control technology
to produce reliable HF power at continuous duty. The LPAs interface directly
with the 9000D series of radios and transmitters, and operate over a frequency
range of 1.5 MHz to 30 MHz, delivering rated output for a load VSWR up to 2:1
over the full-temperature operating range, with graceful degradation for load
VSWR up to 3:1. The amplifiers are protected from damage due to load VSWR
above 3:1 and short or open circuits.
The Sunair LPA-9500 and LPA-9600 use two and four amplifier power supply
modules, respectively, capable of producing over 300W each, which allow the
units to deliver conservative averages of 500W and 1kW. The approach of
combining power supplies and amplifiers in modular form produces considerable
redundancy and protection again failures. Should there be a failure in one of
the LPA-9600 RF/PS modules, the unit will automatically switch to 500W
operation. The LPA-9500 provides selectable power of 500W or 250W, while the
LPA-9600 provides selectable power of 1kW or 500W; and both units allow bypass
operation
Advanced built-in-test (BITE) capability, along with status indicators of
power, individual PA voltages and currents, are all microprocessor-controlled.
In the event of malfunction, the amplifiers automatically select the next
lowest safe operating level, activate a warning light, and display the cause
on the front panel. The amplifiers’ intuitive modular design allows for ease
of maintenance and upgrade throughout the equipment life cycle at minimal
expense. Thousands are in daily service as integral components of critical
strategic communications solutions worldwide.
- Redundant Internal AC Power Supplies
- Soft Fail Design
- Full Power into Load VSWR up to 2:1
- Comprehensive BITE to LRU
GENERAL
GENERAL|
---|---
Frequency Range| 1.5 – 30 MHz
Power Output| * LPA-9600: 1000 W PEP and Average
* LPA-9500: 500 W PEP and Average
Duty Cycle| Continuous
Intermodulation Distortion| 36 dB Below PEP
Harmonic Distortion| 60 dB Below PEP
Band Change Time| 10 ms Maximum
Output Impedance| 50 0 Unbalanced
Load VSWR| * Rated Power ≤ 2:1
* Graceful Degradation ≤ 3:1
* Protected Cut Off Above 3:1
Input VSWR| 2:1 Maximum
Input Voltage| 115 / 230 VAC ±15%, Single Phase 50 – 60 Hz
Input Power| * LPA-9600: 4500 VA Typical (Including Exciter)
* LPA-9500: 2000 VA Typical (Including Exciter)
Indicators| Power On, Fault, Metering, and LCD
Metering| Forward Power, Reflected Power, and PA Voltages and Currents
BITE| Microprocessor-Controlled With English Language Readout
MTBF| 6900 Hours
MTTR| 30 Minutes
Dimensions| * 15.75 H x 17.88 W x 19.0 L (in)
- 40.0 H x 45.4 W x 48.3 L (cm)
Weight| * LPA-9600: 90 lbs (40.9 kg)
- LPA-9500: 70 lbs (31.8 kg)
Construction| Modular Plug-In Assemblies, Field Serviceable
Origin| Designed and Manufactured in the U.S.A.
PRODUCT SPECIFICATIONS
INTERNAL OPTIONS|
---|---
Power Level Setting| Third Level of 250 W
PERIPHERAL EQUIPME| NT OPTIONS
---|---
Mounting| * Ears and Rack Slides For EIA Standard 19 Inch Rack
* Desktop
* Shockmount Kit
Spares Kits| Running Spares, Field Modules
Radios| RT-9000D / R-9000D / T-9000D
1 kW Antenna Couplers| CU-9150
ENVIRONMENTAL|
---|---
Temperature| * Operating: -30°C to +65°C (-22°F to 149°F)
- Storage: -40°C to +85°C (-40°F to 185°F)
Humidity| 95% at 65°C (149°F), Non-Condensing
Shock| MIL-STD 810F, Method 516.5, Procedure 1
Vibration| MIL-STD 810F, Method 514.5 & MIL-STD-167-1
Altitude| * Operating: Up to 10,000 Feet
* Storage: Up to 40,000 Feet
CERTIFICATIONS|
---|---
European CE Standard,| EN 300 373-2 v1.2.1
(Optional)| EN 301 843-5 v1.1.1
| EN 60950
| Notified Body 1177
3131 SW 42ND Street Fort Lauderdale, FL 33312
Tel: 954-623-3131 / 400-5100
Fax: 954-583-7337
sunairelectronics.com
Specifications are subject to change without notice or obligation. Revised:
August 2011
www.sunairelectronics.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>