Section 1: Modification of CM64 from max.100 to max. 300 rev./stroke
Requirements
- Dismount actuator from valve
- Bring actuator in a workshop/workbench
- Prepare all tools and required parts
- This application only applies to CM64, not CM32
Modification Procedure
-
Open the screws between electric housing and mechanical housing.
NOTE:
Make sure that the display is on top position because mechanical housing is filled with oil. -
Remove the pinion by loosening the worm screw.
-
Remove the clipper and replace on the groove below.
-
Mount the pinion back on the shaft and secure it with the worm screw.
-
Place the washer on the shaft and afterwards put the pinion on it.
-
Secure the pinion with a clipper.
-
Make sure that this gear is rotating well by turning the handwheel.
-
Assemble both housings together, making sure the pinions from the electrical and mechanical housings interlock correctly.
-
Parameter configuration
-
Go to System parameters P19.1 and enter password (the password is different for each actuator).
-
For standard SmartTool License Users, please consult Emerson Sales Team for Smart Key to change the parameters.
Change from 100 to 300 revolutions per stroke
Table 1. P19.10
Old value | New value |
---|---|
4 | 5 |
9 | 10 |
12 | 13 |
16 | 17 |
Table 2. P19.11
Old value | New value |
---|---|
0 | 1 |
Change from 300 to 100 revolutions per stroke
Table 3. P19.10
Old value | New value |
---|---|
5 | 4 |
10 | 9 |
13 | 12 |
17 | 16 |
Table 4. P19.11
Old value | New value |
---|---|
1 | 0 |
Parameter P19.10 actuator type references
Table 5. P19.10
4 | CM06 up 100U BLDC 9.3 |
---|---|
5 | CM06 more than 100U BLDC 9.3 |
9 | CM06 up 100U BLDC 8.3 |
10 | CM06 more than 100U BLDC 8.3 |
12 | CM06 24V up 100U BLDC 9.1 |
13 | CM06 24V more than 100U BLDC 9.1 |
16 | CM06 up 100U BLDC 10.3 |
17 | CM06 more than 100U BLDC 10.3 |
Set end limits.
World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers.
Choose the WACC or sales office nearest you:
NORTH & SOUTH AMERICA
NORTH & SOUTH AMERICA
19200 Northwest Freeway Houston TX 77065
USA
T +1 281 477 4100
Av. Hollingsworth
325 Iporanga Sorocaba SP 18087-105
Brazil
T +55 15 3413 8888
MIDDLE EAST & AFRICA
P. O. Box 17033
Jebel Ali Free Zone
Dubai
T +971 4 811 8100
P. O. Box 10305
Jubail 31961
Saudi Arabia
T +966 3 340 8650
24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908 Greenstone
1616 Modderfontein Extension 5 South Africa
T +27 11 451 3700
ASIA PACIFIC
No. 9 Gul Road
01-02 Singapore 629361 T +65 6777 8211
No. 1 Lai Yuan Road Wuqing Development Area Tianjin 301700
P. R. China
T +86 22 8212 3300
EUROPE
Holland Fasor 6
Székesfehérvár 8000
Hungary
T +36 22 53 09 50
Strada Biffi 165
29017 Fiorenzuola d’Arda (PC) Italy
T +39 0523 944 411
For complete list of sales and manufacturing sites, please visit
www.emerson.com/actuationtechnologieslocations
or contact us at
info.actuationtechnologies@emerson.com
www.emerson.com/bettis
VCIOM-17117-EN ©2022 Emerson. All rights reserved. The Emerson logo is a
trademark and service mark of Emerson Electric Co. BettisTM is a mark of one
of the Emerson family of companies. All other marks are property of their
respective owners. The contents of this publication are presented for
information purposes only, and while effort has been made to ensure their
accuracy, they are not to be construed as warranties or guarantees, express or
implied, regarding the products or services described herein or their use or
applicability.
All sales are governed by our terms and conditions, which are available on
request. We reserve the right to modify or improve the designs or
specifications of our products at any time without notice.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>