Medescan NE-MO1L Ultrasonic Mesh Nebuliser Instruction Manual

June 3, 2024
MedeScan

Medescan NE-MO1L Ultrasonic Mesh Nebuliser

Medescan-NE-MO1L-Ultrasonic-Mesh-Nebuliser-FIG- 15

Statements

  • Thank you for purchasing the Medescan Ultrasonic Nebuliser.
  • To ensure correct usage, please read the User Manual carefully before use.
  • Please keep the User Manual in a safe location for future reference.
  • Medescan takes no responsibilities and will not warranty any damage caused by inappropriate use, maintenance, or storage.

Precautions

Please read the user manual carefuly to ensure safe usage.

Warning

  • Please follow doctors’ advice regarding your medication, dosage and usage.
  • Please follow the operating instructions specified in the user manual to avoid unit failure.
  • The accessories of device are designed for single person use. Do not reuse the accessory to avoid cross infection.
  • For the First time using the Medescan Ultrasonic Nebuliser or if the medication cup is unused for a long time, the medication cup and mask must be cleaned and disinfected.
  • After disinfecting the accessories, please ensure thorough rinsing with fresh water to inhaling residual disinfectant.
  • Do not use the device to inhale water.
  • Do not use the device at ambient temperature above 40°C. It may cause nasal mucosa injury or device failure.
  • Do not rinse or soak the main unit in water. Do not store the device in humid environment, otherwise it may cause device failure.
  • Please do clean the device after use and dry it immediately after cleaning.
  • Please keep the device out of the reach of children.
  • Do not use the device near flammable or explosive gas or anesthetic mixture.
  • Possible suffocation danger if power cord wraps on child’s neck.
  • If the device does not auto-shutoff when the medication is totally nebulised, please immediately press the ON/OFF button to turn it off. Refer to Chapter 6 for Troubleshooting.
  • Clean medication cup after each use.
  • Recommended maximum liquid carrying capacity is 10ml, minimum capacity is 2ml.
  • Do not use this product near high-frequency electromagnetic transmitters and other high-frequency electronic products.
  • Keep the device upright during use.
  • Avoid high impact on the device body and accessories.
  • Do not touch the ultrasonic mesh diaphragm with sharp objects as it can void the warranty.
  • The face mask is made of plasticizer-free PVC material
  • Do not use suspended or high-concentration medicinal solutions. Please consult your doctor for specific types of nebulization medication and follow doctor’s recommendations and use.
  • Charge the device if low power appears.
  • If the device will not be used for a long time, please charge it periodically.
  • Children must use the device under direct adult supervision
  • Do not store or carry the device with medication in the medication cup.
  • Disposal of waste main units and accessories shall follow the local government regulations
  • This product cannot be used in respiratory anesthesia systems and ventilator systems.

General

Function and application

The nebulizer can atomize medication into a mist of microscopic droplets, which can be easily inhaled into respiratory system along with breathing, achieving therapeutic effect for respiratory diseases such as acute inflammation of the upper respiratory tract, acute and chronic tracheitis, bronchitis and swelling and pain in throat, etc. The device has two nebulization modes.
Application: inhalation treatment of atomized medication via respiratory system

Features

  • Power supply : DC 5V or (3.7V rechargeable lithium battery)
  • Input power : <5 VA
  • Nebulization rate in level l : > 0.25mL/min
  • Nebulization rate in level ll: > 0.15mL/m in
  • Noise : s50 dB
  • Equivalent volume particle diameter distribution: the volume distribution ratio of small, atomized particles (diameter5 um) is no less than 60 %
  • Type of protection against electric shock: Class II equipment, internally powered equipment
  • Degree of protection against electric shock: type BF applied part
  • Waterproof Rating : IP22
  • Note : Please purchase suitable power adapter (input: AC 100-240V, 50Hz-60Hz, output: DC 5V, 1.0A).

Operational environment

  • Temperature : 5 °C~40°c
  • Humidity : 15 %~90 %
  • Atmospheric pressure : 700 hPa 060 hPa

Attention : This product is not suitable for use in strong electromagnetic interference environments Isuch as various medium/high frequency therapeutic instruments, transformers, large electrical cabinets, radio and television transmission towers, other radio frequency transmitting equipment, and other electrical appliances or medical equipment may generate interference.).

Product Composition

Structure : The nebulizer consists of a body, a medication cup, mask, power cord and adapter loptional).Medescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(8\) Medescan-NE-MO1L-
Ultrasonic-Mesh-Nebuliser-FIG- \(9\)

How to use

Assembly

  1. Remove all packages
    Attention : When using for the first time, please clean and disinfect the device before use.

  2. Assembly of main unit

  3. Install medication cup to the device body.
    Attention : When installing medication cup to the device body, be sure to install to proper position, and you can hear a click sound.Medescan-NE-MO1L-
Ultrasonic-Mesh-Nebuliser-FIG- \(10\)

  4. Remove medication cup from device body. Press and hold the “PUSH button on the body, and push medication cup away from the device body.
    Attention: In order to avoid device damage, please press the “PUSH” button first when removing medication cup.

Medescan-NE-MO1L-Ultrasonic-Mesh-Nebuliser-FIG- \(11\)

Operations for treatment use

Preparations before use:

  1. Remove medication cup, clean and disinfect it before use.

  2. Add medication: Open the cup lid, add medication into medication cup as shown below:
    Attention:

  3. Before using any pharmaceutical products or medicines, please consult your doctor or pharmacist to ensure that you are using the product correctly.

  4. Do not use the medication of high concentrations, high viscosity, oily medicines, suspended or volatile liquid medicine.

  5. It is recommended not to exceed the maximum capacity of medication cup. It medication cup is filled with medication, be sure to close the cup lid to prevent leakage.

  6. Close the cup lid.

  7. Install medication cup to device body.

  8. Assemble the mask, as shown below:

Operation method

  1. Startup: press ON/OFF button to turn on the device, 1 second later, the indicator lights up in green, and the device starts atomizing.

  2. Mode switch: The device has two working modes: level I and level I. Level l is the high nebulization rate mode, level ll is the low nebulization rate mode. User could change the working mode by short pressing ON/OFF button.

  3. Inhalation: Hold the device in hand, put on the mask, slowly inhale the medication mist.
    Attention:

  4. If medication cup is not filled with any medication, the device will automatically switch of. Before turning off, the indicator light flickers orange as a prompt.

  5. After pressing the ON/OFF button, the device will go through a short start up period lwithin 2s), then start atomizing.

  6. When the medication is going to run out, it is recommended to slightly tilt the device towards to user (the side with button should be closer to user), so that the remaining solution could contact the nebulizing diaphragm for atomization.

  7. Due to the difference of characteristics of medicinal solutions, the device may not shutdown automatically when the medication is used up. The user may need to turn off the device man ually to protect the nebulizing diaphragm from damage.

  8. During use, please hold the device steady and do not shake it.

  9. There is an air hole on the lid of medication cup, do not cover it to ensure normal atomization.

  10. Duration of each dosing should be no more than 20 minutes, if you have any discomfort during use, please stop the treatment and consult your doctor or pharmacist.

  11. 4. Turn off the power: If you need to shut the device down during use, please press the
    ON/OFF button, after 1 second, the indicator light goes out and the device turns off.
    Attention:
    In order to prevent the device from accidentally switching on when it is carried in a bag, the
    product is designed to perform power on and off operations after a long press of the button
    for 1 second.
    At the end of treatment, it is normal that a little medication left in medication cup after
    automatically shut off.

Use and Charging of lithium battery

  • Battery operation:
    • The indicator lights up in orange when battery is low, prompting user to charge the device.
    • During normal operation, the battery can continuously work for 1 hour after being fully charged.
  • Charging:
    • Insert the power adapter plug into the power interface on the device.
    • Plug the adapter into a power socket.
      When charging, the indicator lights up in blue, and it goes off automatically after charging is completed.

Attention:

  • Specification of power adapter: input: AC100-240V 50-60Hz, output: DC5V, 1.0A.
  • Please unplug the power adapter after use, avoid connecting with the power for a long time.
  • When the device is left unused for a long time, it should be charged every six months, which could greatly extend the battery life. The battery is not replaceable.

Maintenance, Transport and Storage

Cleaning

Clean and disinfect the device after each use. If the device is not regularly cleaned it may affect the effective performance and medicine delivery.

  1. Remove medication cup and accessory from the device body.
  2. Open the cup lid and discard residual medication.
  3. Add 75% ethanol solution in medication cup, cover the cup lid, then leave it for at least 10mins. Gently shake it for better disinfection.
  4. Immerse the accessories to be disinfected into a container with ethanol solution and close the container. Use 75% ethanol solution soaking for 10mins or longer
  5. Discard the disinfectant in medication cup, take accessories out from the disinfectant; clean the medication cup and accessories with clear water repeatedly.
  6. Fill medication cup with clear water, assemble it to the device body, let the device work 10mins to clean the nebulizing diaphragm.
  7. After cleaning, use new medical gauze to wipe away the water, and fully dry.
  8. Use 75% medicinal alcohol to wipe the surface of device body, then air-dry or wipe- dry with a clean, soft cloth.
  9. After all steps above, store the device body, medication cup and accessories in a dry, clean place.
    Attention :
    Do not disinfect medication cup and accessories in boiling water. Do not put them in a microwave oven for drying.
    The parts disinfected with disinfectant must be fully cleaned and any residual disinfectant removed.

Medication cup replacement

The nebulizing diaphragm is a kind of consumable. Generally, the service life of nebulizing diaphragm is six months [if it is used 3 times a day, 20 mins each time.). Its service life depends on the use method, medication, and the degree of cleaning. If no atomizing or little atomizing appears when device working, please replace medication cup in time. If you need to purchase medication cup, please contact Medescan 1300 736 330.

Transport and storage

Environment of transport and storage:

  • Temperature: -40 °C+55 °C
  • Relative humidity : 5 %96%
  • Atmospheric pressure : 500 hPa – 1060 hPa

Requirement of transport and storage:

  • No corrosive gas and well-ventilated room.
  • Keep the device out of the reach of children.
  • Do not store the device in places such as direct sunlight, high temperature, humid, or dusty environment.
  • Avoid excessive vibration or shocks.

Pollution-free disposal and recycle

Please dispose of in accordance with relevant local laws and regulations.

Troubleshooting

Medescan-NE-MO1L-Ultrasonic-Mesh-Nebuliser-FIG-
\(1\) Medescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(2\)

Symbols

  • The level of waterproof and dustproof rating is IP22.

  • Class I equipment

  • Type BF applied part

  • Keep dry

  • Fragile, handle with care

  • This way up

  • Humidity limitation: 5 %96 %

  • Temperature limitation: -40 °C~+55 °C

  • Atmospheric limitation: 500 hPa – 1060 hPa

  • This item is compliant with Medical Device Directive 93/42/EEC of June 14, 1993, a directive of the European Economic Community.

  • ON/OFF button and Nebulization rate switch button

  • Refer to instruction manual/booklet

  • Note: On ME equipment “follow instructions for use”

  • Serial number

  • Manufacturer

  • WEEE (2002/96/EC)

  • Date of manutacture

COMPONENT

  1. Device body 1pc
  2. User manual ipc
  3. Medication cup 1pc
  4. Accessories 1set ladult mask, child mask)
  5. Power cord 1pc

Appendix I

Curve chart of equivalent volume particle diameter distribution: the median particle diameter [D O.50) is1-4 pm. Error margin within t25 %

Appendix II EMC Guidance and Manufacturer Declaration
Warning:

  • This device should not be used when close to or stacked with other equipment, if necessary, please observe and verify that device can operate normaly in this configuration.
  • The use of ACCESSORIES and cables other than those specified and supplied by manufacturer should not be used.
  • The device complies with the emission and immunity requirement specified in YY0505-2012.

Table 1: Electromagnetic emissionMedescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(3\)

Table 2: Electromagnetic immunity 1Medescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(4\) Medescan-NE-MO1L-
Ultrasonic-Mesh-Nebuliser-FIG- \(5\)

Table 3: Electromagnetic immunity 2Medescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(6\)

Table 4: Recommended safety distandMedescan-NE-MO1L-Ultrasonic-Mesh-
Nebuliser-FIG- \(7\)

Medescan is a product of: TLC Diagnostics Pty Ltd
www.medescan.com.au
infoldmedescan.com.au
1300 736 330